• Title/Summary/Keyword: Radiology services

Search Result 68, Processing Time 0.031 seconds

Study on image quality and dosage comparison of F/S system and DR system (F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토)

  • Kim, Sun-Chil;Jung, Jae-Eun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.7-11
    • /
    • 2003
  • Currently, many hospitals are hastening to introduce digital radiography systems. This is a direct result of the intentions to improve medical services and to digitalize radiology information systems, and is also leading to the improvement of medical imaging technology. Throughout F/S system's long history, many people have researched the image quality and dosage concerning these systems, and as a result, huge improvements in the dosage of patients were possible. Similarly, I believe that DR systems need the same kind of effort. Of course, decreases in dosage that ignore image quality are unthinkable. The results of experiments conducted by five hospitals during a period of 3 months brought to us the conclusions listed below. 1. Based on the comparison and analysis of the exposure control of F/S systems and DR systems, DR systems generally showed higher exposure control for parts of the phantom that became thicker, and the exposure control improved rapidly as the thickness increased. 2. DR systems still proved to be somewhat deficient in resolution measurements compared to existing F/S systems. The image processing part of DR systems contributed much to these result. 3. Under conditions used clinically, the dosage measurements of DR systems were generally higher regardless of region. 4. According to the evaluation of image quality, DR systems showed a higher degree of satisfaction as the thickness of the region became thinner. As mentioned above and based on the mutual relationship experiments between the dosage and image quality of F/S systems and DR systems, research to increase the satisfaction of DR systems must be considered.

  • PDF

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

A Design and Implementation of MINI-PACS Employing the DICOM Converter on Web Environment (웹 상에서 DICOM 변환기를 이용한 MINI-PACS 설계 및 구현)

  • Ji, Youn-Sang;Rhee, Kang-Hyeon;Chung, Il-Yong;Lee, Sung-Joo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.4
    • /
    • pp.39-49
    • /
    • 2001
  • Application of information system to hospital would bring innovative improvement on efficiency of business management and provide high quality services toward patients as well as the retrenchment of operating funds. PACS(Picture Archiving and Communication System) including X-ray film that manages the medical image information effectively, has drawn considerable attention to essential structural elements to the sophisticated information system for hospital. PACS system should be connected to the network after making a form of standard medical image file from different style of image information obtained from various medical instruments. In this paper, to solve this problem, we construct Mini-PACS that converts the form of Non-DICOM file to the form of standard file by designing the DICOM converter. This system is designed to be managed under Web environment. Comparing with the existed Mini-PACSs, consisting of the client and server module, our system is designed and implemented with integration of these functions in order to be strongly combine strongly between system.

  • PDF

Evolution of Large-Scale Filmless Full-PACS in Korea

  • Kim, Hee-Joung;Haijo Jung;Yoo, Hyung-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.28-31
    • /
    • 2002
  • Filmless full-PACS in korea has rapidly been growing, since government had supported collaborative PACS project between industry and university hospital in late of 1995. At the same time, a small company had started PACS business, while the Korea PACS society was being formed. In the beginning, PACS societies had focused on developing peripheral solutions such as DICOM gateway for image acquisition, x-ray film digitizer, and viewing software for research or management of personal image data, while Samsung Medical Center had started installing an imported partial PACS system which had recently upgraded with a new system. In similar time frame, a few hospitals had started developing and installing domestic large scale full-PACS system. Several years later, many hospitals have installed full-PACS system with national policy of reimbursement for PACS exams in November 1999. It is believed that Korea is the first country that adopted PACS reimbursement for filmless full-PACS as a national policy. Both experiences of full-PACS installation and national policy generated tremendous intellectual and technological expertise about PACS at all levels, clinical, hospital management, education, and industrial sectors. There are currently three types of PACS system which includes domestic, imported, and hybrid PACS system with imported solution for core system and domestic solution for peripheral system. There are more than 20 domestic PACS companies and they have now enough experiences so that they are capable of installing a truly full-PACS system for large-scale teaching hospitals. PACS societies in Korea understand how to design, implement, install, manage, sustain, and provide good services for large-scale full-PACS. PACS society has also strength for the highest integration technology of the Hospital Information. However, further understanding and timely implementation of continuously evolving international standard and integrated healthcare enterprise concepts may be necessary for international leading of PACS technologies for the future.

  • PDF

Is Mammography for Breast Cancer Screening Cost-Effective in Both Western and Asian Countries?: Results of a Systematic Review

  • Yoo, Ki-Bong;Kwon, Jeoung A;Cho, Eun;Kang, Moon Hae;Nam, Jung-Mo;Choi, Kui Son;Kim, Eun Kyung;Choi, Yun Jeong;Park, Eun-Cheol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4141-4149
    • /
    • 2013
  • Background: Mammography is considered the gold standard of breast cancer mass screening and many countries have implemented this as an established breast cancer screening strategy. However, although the incidence of breast cancer and racial characteristics are different between Western and Asian countries, many Asian countries adopted mammography for mass screening. Therefore, the objective of this research was to determine whether mammography mass screening is cost-effective for both Western and Asian countries. Materials and Methods: A systematic review was performed of 17 national mammography cost-effectiveness data sets. Per capita gross domestic product (GDP), breast cancer incidence rate, and the most optimal cost-effectiveness results [cost per life year saved (LYS)] of a mammography screening strategy for each data set were extracted. The CE/per capita GDP ratio is used to compare the cost-effectiveness of mammography by countries. Non-parametric regression was used to find a cut-off point which indicated the breast cancer incidence rate boundary line determining whether mammography screening is cost-effective or not. Results: We found that the cost-effective cut-off point of breast cancer incidence rate was 45.04; it exactly divided countries into Western and Asian countries (p<0.0014). Conclusions: Mammography screening is cost-effective in most of Western countries, but not in Asian countries. The reason for this result may be the issues of incidence rate or racial characteristics, such as dense breast tissue. The results indicate that mammography screening should be adopted prudently in Asian countries and other countries with low incidence rates.

Survey of Satisfaction with Oriental Medical Care for Traffic Accident Patients ; 35 Cases Report (교통사고 환자 35예에 대한 한방의료 서비스 만족도 조사)

  • Park, Darn-Seo;Pi, Chien-Hsin;Lee, Jeong-Han;Kong, Jae-Cheol;Baek, Dong-Gi;Song, Yung-Sun;Kwon, Young-Mi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.3
    • /
    • pp.99-118
    • /
    • 2008
  • Objectives : This study aimed to understand the satisfaction degree of patients due to traffic accident(TA) in order to provide basic data which would give help not only to improve the quality of services, but also to strengthen the competitiveness of oriental medical hospitals on sequela of TA patients. Methods : The data were collected from inpatients and outpatients who answered a self-report questionnaire. Independent t-test, analysis of variance(ANOVA), $X^2$-test, correlation analysis were used for data analysis. Results : According to the research on medical satisfaction degree, the overall satisfaction degree was 4.141. On each field, satisfaction degree related to the doctor service recorded the highest degree among others(4.474). Satisfaction degree related to the appropriateness of service was the second(4.091). On the other hand, satisfaction degree of using procedure was the lowest degree(3.857). On the difference of degrees of satisfaction by general characteristics, patients who were unemployed houseworker group showed lower doctor service satisfaction degree than that of other groups. However, on the difference of degrees of satisfaction related to other general characteristics, there were no significant differences(p<0.05). Conclusions : The service distribution of oriental medical hospital was almost equal without concentrating on specified social classes.

Estimation of Appropriate Number of Radiologic Technologist Based on Analysis of Time Required for Computed Tomography (전산화단층촬영의 소요시간 분석에 기반한 방사선사의 적정인력 산정에 관한 연구)

  • Lee, Ki-Baek;Kim, Yung-Kyoon;Kim, Eun-Hye;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.213-223
    • /
    • 2022
  • Although the number of computed tomography(CT) is increasing every year, it is insufficient to establish appropriate workload calculation standards of radiologic technologist to provide optimal medical services to patients, such as patient safety management and infection management. The purpose of this study is to present guidelines for calculating the appropriate workload of radiologic technologist by analyzing the work flow of CT procedures and the time required for CT examination in major hospitals. As for the study subjects and methods, the appropriate process for each step of CT examination was investigated to systematically present the process and time required for the actual examination, and the CT procedure time of 104,105 adult patients and 465 pediatric patients under the age of 6 were analyzed. For the time required, data according to the use of contrast medium, procedure type, and adult/child were collected and compared. The test time of CT examination using contrast medium took about 13 minutes when one radiologic technologist worked and about 9 minutes when two radiologic technologists worked. The time required for the procedures were statistically significant depending on the presence or absence of contrast medium, multi-phase procedure, and patient age (considering pediatric patients). As a result, in order to thoroughly perform patient safety and infection management, the appropriate workload increased by about 40% when there were two radiologic technologists. The limit workload was an average of 32 people per day with one radiologic technologist per 15 minutes, and 48 people per day with two radiologic technologist per 10 minutes. This is a marginal workload, and in the case of procedures that require more time to acquire radiographic images, the interval between reservations should be widened.

Effective Customer Risk Management at the Nuclear Medicine Department: Risk Managemont MOT Development Application and Producing Public Relations Film (핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작)

  • Ham, Jong-Hum;Hwang, Jae-Bong;Kim, Joon-Ho;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.110-122
    • /
    • 2009
  • Purpose: Nowadays, A medical institution assesment could get more interest about a quality of medical services from many hospitals that developed the active activities for improving medical services. Also, there is an other additional issue which is the patients risk management. Uijeongbu ST. Mary's hospital Nuclear Medicine department has been changed many work process after PET-CT introduction and renovation of its place since 2008. Therefore, modified structure and the way of existing work process have contained risk factors. The purpose of this study would be the appropriate risk management process while imaging examination process, the removal risk factors and improved activities through the analysis risk factors. Materials and Methods: Nuclear Medicine department new process should analysis through many-sided, Firstly, make and trained risk management manual after then apply an actual work. Result analysis showed the number of risk accident occurrence that comparing the last year and after the improved activities. Secondly, producing risk management public relations film has been showed an applicable patient after then the customer service measurement checked for a hundred patient by questionnaire. Lastly, Risk factors were eliminated through the facilities participation improving activities which could change for the better risk factors. Results: The number of safety accident occurrence(medication error, fall and collision) were checked as zero after the improving activities both PET-CT and gamma camera examination. The results of questionnaire showed as follows; 74% marked as understanding of the test process and 81% checked "satisfaction" after the public relations film showing. The question "Did you consider about the risk factors?", both PET-CT and gamma camera checked as 94% and 89% respectively. Customer risk management could be accomplished effectively through the improving activities at the nuclear medicine department. Conclusions: The study would be an opportunity that spread risk factors were systematically showed and analyzied. Also, It showed the possibility of the minimized safety accident and its feedback, if application of the response manuel that could be a standard of radiology technician's work method to react safety accident. It was the more effective that visual material could be easy to approach as a methodology of risk factors. As far as I have concerned that It could help the safety and convenience through continuous and detailed activities that offer to patients.

  • PDF

Development of the Model for Total Quality Management and Cost of Quality using Activity Based Costing in the Hospital (병원의 활동기준원가를 이용한 총체적 질관리 모형 및 질비용 산출 모형 개발)

  • 조우현;전기홍;이해종;박은철;김병조;김보경;이상규
    • Health Policy and Management
    • /
    • v.11 no.2
    • /
    • pp.141-168
    • /
    • 2001
  • Healthcare service organizations can apply the cost of quality(COQ) model as a method to evaluate a service quality improvement project such as Total Quality Management (TQM). COQ model has been used to quantify and evaluate the efficiency and effectiveness of TQM project through estimation between cost and benefit in intervention for a quality Improvement to provide satisfied services for a customer, and to identify a non value added process. For estimating cost of quality, We used activities and activity costs based on Activity Based Costing(ABC) system. These procedures let the researchers know whether the process is value-added by each activity, and identify a process to require improvement in TQM project. Through the series of procedures, health care organizations are service organizations can identify a problem in their quality improvement programs, solve the problem, and improve their quality of care for their costumers with optimized cost. The study subject was a quality improvement program of the department of radiology department in a hospital with n bed sizes in Metropolitan Statistical Area (MSA). The principal source of data for developing the COQ model was total cases of retaking shots for diagnoses during five months period from December of the 1998 to April of the 1999 in the department. First of the procedures, for estimating activity based cost of the department of diagnostic radiology, the researchers analyzed total department health insurance claims to identify activities and activity costs using one year period health insurance claims from September of the 1998 to August of the 1999. COQ model in this study applied Simpson & Multher's COQ(SM's COQ) model, and SM's COQ model divided cost of quality into failure cost with external and internal failure cost, and evaluation/prevention cost. The researchers identified contents for cost of quality, defined activities and activity costs for each content with the SM's COQ model, and finally made the formula for estimating activity costs relating to implementing service quality improvement program. The results from the formula for estimating cost of quality were following: 1. The reasons for retaking shots were largely classified into technique, appliances, patients, quality management, non-appliances, doctors, and unclassified. These classifications by reasons were allocated into each office doing re-taking shots. Therefore, total retaking shots categorized by reasons and offices, the researchers identified internal and external failure costs based on these categories. 2. The researchers have developed cost of quality (COQ) model, identified activities by content for cost of quality, assessed activity driving factors and activity contribution rate, and calculated total cost by each content for cost for quality, except for activity cost. 3. According to estimation of cost of quality for retaking shots in department of diagnostic radiology, the failure cost was ₩35,880, evaluation/preventive cost was ₩72,521, two times as much as failure cost. The proportion between internal failure cost and external failure cost in failure cost is similar. The study cannot identify trends on input cost and quality improving in cost of qualify over the time, because the study employs cross-sectional design. Even with this limitation, results of this study are much meaningful. This study shows possibility to evaluate value on the process of TQM subjects using activities and activity costs by ABC system, and this study can objectively evaluate quality improvement program through quantitative comparing input costs with marginal benefits in quality improvement.

  • PDF

Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist (방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도)

  • Kim, Eun-Hye;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Moon, Young-Ju;Kim, Hoon;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Cho, Pyong-Kon;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.