• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.031 seconds

Evaluation of oral and maxillofacial swellings using ultrasonographic features

  • Abdelsalam, Tarek Abdallah;Amer, Maha Eshak;Mahrous, Ahmed;Abdelkader, Moustafa
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.201-208
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the characteristic features of oral and maxillofacial swellings that could be seen on ultrasonographic examinations. Materials and Methods: Fifty patients with oral and/or maxillofacial swellings were randomly selected, thorough case histories and clinical examinations were done, ultrasonographic examinations with Doppler imaging were performed, and the features of every group were studied. Finally, histopathological evaluations were performed to identify the final diagnosis, according to which patients were classified into 5 groups; group I: inflammatory/space infection and abscess swellings, group II: cystic swellings, group III: lymph node swellings, group IV: benign swellings, and group V: malignant neoplastic swellings. Results: A significant association (P<0.05), with a contingency coefficient of 0.88, was found between the histopathological and ultrasonographic diagnoses, with ultrasonography having a diagnostic accuracy of 89% in diagnosing maxillofacial swellings. The diagnostic accuracy of ultrasonography was 100% for lymph node and malignant swellings, followed by 98% for inflammatory and cystic swellings and 92% for benign swellings. The sensitivity of the ultrasonographic diagnosis was 100% for cystic, lymph node, and malignant swellings, followed by 91% for inflammatory swellings and 86% for benign swellings. Conclusion: Ultrasonographic features with Doppler imaging greatly aid in obtaining accurate diagnoses of oral and maxillofacial swellings. Ultrasonography is a recommended imaging tool for differentiating maxillofacial swellings and classifying them accurately.

A rare case report of ameloblastic fibrodentinoma with imaging features in a pediatric patient

  • Youjin Jung;Kyu-Young Oh;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.207-210
    • /
    • 2024
  • Ameloblastic fibrodentinoma (AFD) is a rare benign odontogenic tumor that resembles an ameloblastic fibroma with dysplastic dentin. This report presents a rare case of mandibular AFD with imaging features in a young patient. Panoramic radiography and computed tomography revealed a well-defined lesion with internal septa and calcified foci, causing inferior displacement of the adjacent molars as well as buccolingual cortical thinning and expansion of the posterior mandible. The lesion was surgically removed via mass excision, and the involved tooth was extracted under general anesthesia. During the 5-year follow-up period, no evidence of recurrence was observed. Radiologic features of AFD typically reveal a moderately to well-defined mixed lesion with varying degrees of radiopacity, reflecting the extent of dentin formation. Radiologists should consider AFD in the differential diagnosis when encountering a multilocular lesion with little dense radiopacity, particularly if it is associated with delayed eruption, impaction, or absence of involved teeth, on radiographic images of young patients.

Development of Knee Radiography Auxiliary Device (무릎 방사선 검사 보조장비의 개발)

  • Do-Byung Rhee;Il-Hwan Bae;Hye-Jung Kim;So-Mi Lee;Deok-Mun Kwon;Dong-Ho Choi;Hee-June Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.87-95
    • /
    • 2024
  • Most knee axial radiographs, known as sunrise and skyline view, were performed with the patient in the prone position. The authors tried to address some of the shortcomings of conventional radiography by developing a new radiography method, K-RAD. According to previous research, the K-RAD method showed a wider patellar-femoral joint space than conventional radiography and provided a clear patellar hemi-lateral image with a constant gap between the femoral trochlear groove and tibial tuberosity. The authors worked with an orthopedic specialist to perform radiography using the K-RAD method rather than using existing methods, and as a result, the two knees were aligned correctly and a clear image of the patellar-femoral joint space was created. The authors propose the K-RAD method for knee axial radiography because the K-RAD method provides a sense of stability to the patient and provides images with high diagnostic value.

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

Viscoelastic Property of the Brain Assessed With Magnetic Resonance Elastography and Its Association With Glymphatic System in Neurologically Normal Individuals

  • Bio Joo;So Yeon Won;Ralph Sinkus;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.564-573
    • /
    • 2023
  • Objective: To investigate the feasibility of assessing the viscoelastic properties of the brain using magnetic resonance elastography (MRE) and a novel MRE transducer to determine the relationship between the viscoelastic properties and glymphatic function in neurologically normal individuals. Materials and Methods: This prospective study included 47 neurologically normal individuals aged 23-74 years (male-to-female ratio, 21:26). The MRE was acquired using a gravitational transducer based on a rotational eccentric mass as the driving system. The magnitude of the complex shear modulus |G*| and the phase angle 𝛗 were measured in the centrum semiovale area. To evaluate glymphatic function, the Diffusion Tensor Image Analysis Along the Perivascular Space (DTI-ALPS) method was utilized and the ALPS index was calculated. Univariable and multivariable (variables with P < 0.2 from the univariable analysis) linear regression analyses were performed for |G*| and 𝛗 and included sex, age, normalized white matter hyperintensity (WMH) volume, brain parenchymal volume, and ALPS index as covariates. Results: In the univariable analysis for |G*|, age (P = 0.005), brain parenchymal volume (P = 0.152), normalized WMH volume (P = 0.011), and ALPS index (P = 0.005) were identified as candidates with P < 0.2. In the multivariable analysis, only the ALPS index was independently associated with |G*|, showing a positive relationship (β = 0.300, P = 0.029). For 𝛗, normalized WMH volume (P = 0.128) and ALPS index (P = 0.015) were identified as candidates for multivariable analysis, and only the ALPS index was independently associated with 𝛗 (β = 0.057, P = 0.039). Conclusion: Brain MRE using a gravitational transducer is feasible in neurologically normal individuals over a wide age range. The significant correlation between the viscoelastic properties of the brain and glymphatic function suggests that a more organized or preserved microenvironment of the brain parenchyma is associated with a more unimpeded glymphatic fluid flow.

Large Language Models: A Comprehensive Guide for Radiologists (대형 언어 모델: 영상의학 전문가를 위한 종합 안내서)

  • Sunkyu Kim;Choong-kun Lee;Seung-seob Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.5
    • /
    • pp.861-882
    • /
    • 2024
  • Large language models (LLMs) have revolutionized the global landscape of technology beyond the field of natural language processing. Owing to their extensive pre-training using vast datasets, contemporary LLMs can handle tasks ranging from general functionalities to domain-specific areas, such as radiology, without the need for additional fine-tuning. Importantly, LLMs are on a trajectory of rapid evolution, addressing challenges such as hallucination, bias in training data, high training costs, performance drift, and privacy issues, along with the inclusion of multimodal inputs. The concept of small, on-premise open source LLMs has garnered growing interest, as fine-tuning to medical domain knowledge, addressing efficiency and privacy issues, and managing performance drift can be effectively and simultaneously achieved. This review provides conceptual knowledge, actionable guidance, and an overview of the current technological landscape and future directions in LLMs for radiologists.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

  • Mohammadpour, Mahdis;Bakhshalian, Neema;Shahab, Shahriar;Sadeghi, Shaya;Ataee, Mona;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols

  • Matheus Barros-Costa;Eduarda Helena Leandro Nascimento;Iago Filipe Correia-Dantas;Matheus L. Oliveira;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR(P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.