• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.033 seconds

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

Preoperative implant planning considering alveolar bone grafting needs and complication prediction using panoramic versus CBCT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • Purpose: This study was performed to determine the efficacy of observers' prediction for the need of bone grafting and presence of perioperative complications on the basis of cone-beam computed tomography (CBCT) and panoramic radiographic (PAN) planning as compared to the surgical outcome. Materials and Methods: One hundred and eight partially edentulous patients with a need for implant rehabilitation were referred for preoperative imaging. Imaging consisted of PAN and CBCT images. Four observers carried out implant planning using PAN image datasets, and at least one month later, using CBCT image datasets. Based on their own planning, the observers assessed the need for bone graft augmentation as well as complication prediction. The implant length and diameter, the need for bone graft augmentation, and the occurrence of anatomical complications during planning and implant placement were statistically compared. Results: In the 108 patients, 365 implants were installed. Receiver operating characteristic analyses of both PAN and CBCT preoperative planning showed that CBCT performed better than PAN-based planning with respect to the need for bone graft augmentation and perioperative complications. The sensitivity and the specificity of CBCT for implant complications were 96.5% and 90.5%, respectively, and for bone graft augmentation, they were 95.2% and 96.3%, respectively. Significant differences were found between PAN-based planning and the surgery of posterior implant lengths. Conclusion: Our findings indicated that CBCT-based preoperative implant planning enabled treatment planning with a higher degree of prediction and agreement as compared to the surgical standard. In PAN-based surgery, the prediction of implant length was poor.

Intra-articular calcifications of the temporomandibular joint and associations with degenerative bone alterations

  • de Almeida, Daniela;de Souza, Patricia Schmidt Araujo Passos;de Mendonca, Luana Pereira;Verner, Francielle Silvestre;Devito, Karina Lopes
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.99-104
    • /
    • 2020
  • Purpose: The purpose of this study was to use cone-beam computed tomography (CBCT) images to determine the prevalence of calcifications in the temporomandibular joint (TMJ) and to evaluate any associations between the presence of such calcifications and degenerative bone alterations of the TMJ, sex, or age. Materials and Methods: In this retrospective study, 1,058 CBCT exams were analyzed, and data regarding the presence and quantity of calcifications, the affected side, any degenerative alterations of the condyle, sex, and age were collected. To evaluate associations between the presence of calcifications and sex or age, the Fisher exact test or the Spearman correlation coefficient, respectively, was used. To assess the association between the presence of calcifications and joint bone alterations, the chi-square and Fisher exact tests were used. The significance level adopted was 5% (P<0.05). Results: Twenty-eight patients (2.7%) presented with TMJ calcifications, including 23 women (82.1%) and 5 men (17.9%). Significant correlations were found between the presence of calcifications and age (P<0.05) and between the presence of calcifications and the presence of condylar alterations (P<0.05), with 73.2% of patients with bone alterations having TMJ calcifications. Conclusion: It may be concluded that, although rare (with a prevalence of only 2.7%), intra-articular calcifications are associated with both degenerative bone alterations and age.

Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery

  • Bari, Roberto Di;Coronelli, Roberto;Cicconetti, Andrea
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.135-143
    • /
    • 2013
  • Purpose: This study was performed to obtain a quantitative evaluation of the cortical and cancellous bone graft harvestable from the mental and canine regions, and to evaluate the cortical vestibular thickness. Materials and Methods: This study collected cone-beam computed tomographic (CBCT) images of 100 Italian patients. The limits of the mental region were established: 5 mm in front of the medial margin of each mental foramen, 5 mm under the apex of each tooth present, and above the inferior mandibular cortex. Cortical and cancellous bone volumes were evaluated using SimPlant software (SimPlant 3-D Pro, Materialize, Leuven, Belgium) tools. In addition, the cortical vestibular thickness (minimal and maximal values) was evaluated in 3 cross-sections corresponding to the right canine tooth (3R), the median section (M), and the left canine tooth (3L). Results: The cortical volume was $0.71{\pm}0.23mL$ (0.27-1.96 mL) and the cancellous volume was $2.16{\pm}0.76mL$ (0.86-6.28 mL). The minimal cortical vestibular thickness was $1.54{\pm}0.41mm$ (0.61-3.25 mm), and the maximal cortical vestibular thickness was $3.14{\pm}0.75mm$ (1.01-5.83 mm). Conclusion: The use of the imaging software allowed a patient-specific assessment of mental and canine region bone availability. The proposed evaluation method might help the surgeon in the selection of the donor site by the comparison between bone availability in the donor site and the reconstructive exigency of the recipient site.

Clinical characteristics of oral diseases on stray cats in Gwangju (광주지역 길고양이 구강질환의 임상적 특성)

  • Myung, Bo Young;Kim, Se Eun;Shim, Kyung Mi;Ryu, Ji Won;Kim, Sung Ho;Moon, Changjong;Bae, Chun-Sik;Choi, Seok-Hwa;Kang, Seong Soo;Park, Hyunjeong
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.4
    • /
    • pp.303-310
    • /
    • 2010
  • Demand on specialized feline dentistry has increased over the years, partly due to growing feline population in Korea. Despite the notable increase in the population, not much researches has been conducted on oral disease for stray cats. Thus this research was conducted on 81 adult stray cats from Gwangju in Korea (42 males and 39 females) with average weight of 3.4 kg and also focused on occurrence of periodontal disease (plaque and calculus), feline odontoclastic resorptive lesion (FORL), stomatitis and tooth anomaly. Formation of dental plaque and calculus were abundant on maxilla than mandible, especially distributed much on 4th premolar teeth and 1st molar teeth. After thorough examination of oral cavity, 33 stray cats (40.7%) were found to have oral disease. Eighteen stray cats (22.2%) had tooth fracture which was evident on cuspid and missing teeth were present on 2nd premolar tooth of maxilla and 2nd incisor of mandible amongst 20 stray cats (24.7%). FORL was present on cuspids and 2nd premolar tooth of maxilla among 10 stray cats (12.3%). Stomatitis was involved with FORL, missing tooth, and tooth fracture. Therefore, it was determined that stomatitis, FORL, and periodontal disease were closely associated.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Sex-, growth pattern-, and growth status-related variability in maxillary and mandibular buccal cortical thickness and density

  • Schneider, Sydney;Gandhi, Vaibhav;Upadhyay, Madhur;Allareddy, Veerasathpurush;Tadinada, Aditya;Yadav, Sumit
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.108-119
    • /
    • 2020
  • Objective: The primary objective of this study was to quantitatively analyze the bone parameters (thickness and density) at four different interdental areas from the distal region of the canine to the mesial region of the second molar in the maxilla and the mandible. The secondary aim was to compare and contrast the bone parameters at these specific locations in terms of sex, growth status, and facial type. Methods: This retrospective cone-beam computed tomography (CBCT) study reviewed 290 CBCT images of patients seeking orthodontic treatment. Cortical bone thickness in millimeters (mm) and density in pixel intensity value were measured for the regions (1) between the canine and first premolar, (2) between the first and second premolars, (3) between the second premolar and first molar, and (4) between the first and second molars. At each location, the bone thickness and density were measured at distances of 2, 6, and 10 mm from the alveolar crest. Results: The sex comparison (male vs. female) in cortical bone thickness showed no significant difference (p > 0.001). The bone density in growing subjects was significantly (p < 0.001) lower than that in non-growing subjects for most locations. There was no significant difference (p > 0.001) in bone parameters in relation to facial pattern in the maxilla and mandible for most sites. Conclusions: There was no significant sex-related difference in cortical bone thickness. The buccal cortical bone density was higher in females than in males. Bone parameters were similar for subjects with hyperdivergent, hypodivergent, and normodivergent facial patterns.

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.