• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.034 seconds

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Medical Student Career Choice and Career Planning (의과대학생들의 진로선택과 진로지도)

  • Kim, Sang Hyun;Yoon, Yoo-sag;Jeon, Woo-Tack;Yang, Eunbae
    • Korean Medical Education Review
    • /
    • v.9 no.2
    • /
    • pp.29-40
    • /
    • 2007
  • Purpose: This study analysed the intention of medical students career choice, educational programmes, and mentoring and counseling system for career planning at Yonsei medical school in Korea. Methods: The data were collected based on four separate graduation questionnaires at Yonsei medical school in the years of 2005, 2006, 2007, and 2008. The number of the survey was 130 in 2005, 130 in 2006, 153 in 2007, and that of the latest was 120 in 2008. We analysed the career intention on medical specialties and activities, and perceptions of important factors in choosing medical specialty. Results : The results which can be drawn from this study are these: firstly. students had more intention for choosing clinical medicine as university faculty than any other activities. While male students preferred to major in surgery, neurosurgery, orthopedic surgery, urology, otorhinolaryngology, female students in internal medicine, neurology, anesthesiology and pain medicine, diagnostic radiology, laboratory medicine. Secondly, students perceived that the most important factor which can influence on choosing a medical specialty was individual factor such as one's interests and concerns, values, and aptitudes. In stead, they relatively less perceived mentor and role model's effects on choosing a medical specialty compared to those of the United States of America. Third, the career planning at Yonsei medical school was evaluated well, especially educational programmes for career planning such as self assessment programme, elective(specialized) courses, and conversation with a senior programme. Conclusions: Unexpectedly, there are high demands for career planning by medical students. Therefore, we will reorganize systematic devices for career planning such as mentoring and counseling system at medical school.

Bone regeneration and graft material resorption in extraction sockets grafted with bioactive silica-calcium phosphate composite (SCPC) versus non-grafted sockets: clinical, radiographic, and histological findings

  • Adel-Khattab, Doaa;Afifi, Nermeen S.;el Sadat, Shaimaa M. Abu;Aboul-Fotouh, Mona N.;Tarek, Karim;Horowitz, Robert A.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.418-434
    • /
    • 2020
  • Purpose: The purpose of the present study was to evaluate the effect of silica-calcium phosphate composite (SCPC) granules on bone regeneration in extraction sockets. Methods: Ten patients were selected for a split-model study. In each patient, bone healing in SCPC-grafted and control ungrafted sockets was analyzed through clinical, radiographic, histomorphometric, and immunohistochemical assessments 6 months postoperatively. Results: A radiographic assessment using cone-beam computed tomography showed minimal ridge dimension changes in SCPC-grafted sockets, with 0.39 mm and 1.79 mm decreases in height and width, respectively. Core bone biopsy samples were obtained 6 months post-extraction during implant placement and analyzed. The average percent areas occupied by mature bone, woven bone, and remnant particles in the SCPC-grafted sockets were 41.3%±12%, 20.1%±9.5%, and 5.3%±4.4%, respectively. The percent areas of mature bone and woven bone formed in the control ungrafted sockets at the same time point were 31%±14% and 24.1%±9.4%, respectively. Histochemical and immunohistochemical analyses showed dense mineralized bundles of type I collagen with high osteopontin expression intensity in the grafted sockets. The newly formed bone was well vascularized, with numerous active osteoblasts, Haversian systems, and osteocytes indicating maturation. In contrast, the new bone in the control ungrafted sockets was immature, rich in type III collagen, and had a low osteocyte density. Conclusions: The resorption of SCPC granules in 6 months was coordinated with better new bone formation than was observed in untreated sockets. SCPC is a resorbable bone graft material that enhances bone formation and maturation through its stimulatory effect on bone cell function.

Comparative, Integrated Study on emotional support, physical support, Socio-economic Factors related with Suicidal Ideation of 75 or older Seniors: Using the 2017 National Survey of Elderly (후기노인의 정서적, 신체적, 사회경제적 요인과 자살생각과의 비교융합연구: 2017년도 노인실태조사 자료를 활용하여)

  • Kim, Young-Ran;Park, Chang-Soo;Nam, Ho-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.63-70
    • /
    • 2019
  • This study examined the effect of emotional factors, physical factors and socioeconomic factors on suicidal ideation of 75 or older seniors and sought to identify what kinds of factors should be satisfied to prevent their suicide. Using "2017 National Survey of the Elderly", the study conducted survey among 75 or older 3,023 males and 1,295 females. It used multivariate logistic regression analysis to identify the factors affecting suicidal ideation. As a result, the study found that ties with their offspring, the number of chronic diseases, being abused or not, depression and living with or without espouse had significant effects on their suicidal ideation and abuse was the largest factor. Therefore, in order to reduce suicide rate of 75 or older seniors, more active attention should be rendered to their physical, socioeconomic and emotional health problems, and measures to reduce elderly abuse should be sought. In particular, institutional improvement and revitalization of elderly counseling institutions are needed to reduce elder abuse

Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis

  • Chagas, Mariana Murai;Kobayashi-Velasco, Solange;Gimenez, Thais;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.363-372
    • /
    • 2021
  • Purpose: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects(0.73) and fenestration defects(0.87) showed a statistically significant difference. Conclusion: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

The Vectra M3 3-dimensional digital stereophotogrammetry system: A reliable technique for detecting chin asymmetry

  • Hansson, Stina;Ostlund, Emil;Bazargani, Farhan
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.43-51
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the reliability of the Vectra M3 (3D Imaging System; Canfield Scientific, Parsippany, NJ, USA) in detecting chin asymmetry, and to assess whether the automatic markerless tracking function is reliable compared to manually plotting landmarks. Materials and Methods: Twenty subjects (18 females and 2 males) with a mean age of 42.5±10.5 years were included. Three-dimensional image acquisition was carried out on all subjects with simulated chin deviation in 4 stages (1-4 mm). The images were analyzed by 2 independent observers through manually plotting landmarks and by Vectra software auto-tracking mode. Repeated-measures analysis of variance and the Tukey post-hoc test were performed to evaluate the differences in mean measurements between the 2 operators and the software for measuring chin deviation in 4 stages. The intraclass correlation coefficient (ICC) was calculated to estimate the intra- and inter-examiner reliability. Results: No significant difference was found between the accuracy of manually plotting landmarks between observers 1 and 2 and the auto-tracking mode (P=0.783 and P=0.999, respectively). The mean difference in detecting the degree of deviation according to the stage was <0.5 mm for all landmarks. Conclusion: The auto-tracking mode could be considered as reliable as manually plotted landmarks in detecting small chin deviations with the Vectra® M3. The effect on the soft tissue when constructing a known dental movement yielded a small overestimation of the soft tissue movement compared to the dental movement (mean value<0.5 mm), which can be considered clinically non-significant.

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

Leptomeningeal Metastasis in Gliomas : Clinical Characteristics and Risk Factors

  • Jeyul Yang;Ji-Woong Kwon;Sang Hoon Shin;Heon Yoo;Kyu-Chang Wang;Sang Heyon Lee;Ho-Shin Gwak
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.465-475
    • /
    • 2023
  • Objective : Our objective is to analyze the occurrence, clinical course and risk factors for glioma patients with leptomeningeal metastasis (LM) according to different metastasis patterns and clinical variables. Methods : We retrospectively reviewed data from 376 World Health Organization (WHO) grade II-IV adult glioma patients who were treated in the National Cancer Center from 2001 to 2020. Patients who underwent surgery at other institutions, those without initial images or those with pathologically unconfirmed cases were excluded. LM was diagnosed based on magnetic resonance imaging (MRI) findings or cerebrospinal fluid (CSF) cytology. The metastasis pattern was categorized as nodular or linear according to the enhancement pattern. Tumor proximity to the CSF space was classified as involved or separated, whereas location of the tumor was dichotomized as midline, for tumors residing in the thalamus, basal ganglia and brainstem, or lateral, for tumors residing in the cerebral and cerebellar hemispheres. Results : A total of 138 patients were enrolled in the study. A total of 44 patients (38%) were diagnosed with LM during a median follow-up of 9 months (range, 0-60). Among the clinical variables, tumor proximity to CSF space, the location of the tumor and the WHO grade were significant factors for LM development in univariate analysis. In multivariate analysis, the midline location of the tumor and WHO grade IV gliomas were the most significant factor for LM development. The hazard ratio was 2.624 for midline located gliomas (95% confidence interval [CI], 1.384-4.974; p=0.003) and 3.008 for WHO grade IV gliomas (95% CI, 1.379-6.561; p=0.006). Conclusion : Midline location and histological grading are an important factor for LM in glioma patients. The proximity to the CSF circulation pathway is also an important factor for WHO grade IV glioma LM. Patients carrying high risks should be followed up more thoroughly.

Cervical Cancer Screening Factors in Women With Disabilities Using Big Data Analysis -Focused on National Cancer Screening Subjects- (빅데이터 분석을 이용한 여성 장애인의 자궁경부암 수검 요인 -국가암 검진 대상자 중심-)

  • Jong-bae Park;Young-bok Cho;Min-Hee Park
    • Journal of Practical Engineering Education
    • /
    • v.15 no.2
    • /
    • pp.495-502
    • /
    • 2023
  • Despite the fact that Korea has supported national cancer screening worldwide for a long time, the cancer screening screening rate is low compared to other health screenings and infant screening. In particular, women with disabilities show a lower screening rate for cervical cancer screening compared to women without disabilities. Therefore, from 2011 to 2019, this study investigated the trends in cervical cancer screening rates of women with disabilities and non-disabled women aged 30 and older, and analyzed the factors affecting cervical cancer screening of women with disabilities at the individual and regional level through the cervical cancer screening rates among regions. The purpose of this study is to identify the factors that affect regional variation by dividing into regions. From 2011~2019, the cervical cancer screening rate of people with disabilities was the highest in Daejeon and the lowest in Sejong and Jeju, and the gap in cervical cancer screening rate of people with disabilities by region was analyzed to be up to 13.1%.