• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.034 seconds

Evaluation of the Effect of Exercise on Nonalcoholic Fatty Liver By Sonography (초음파 검사를 이용한 비알코올성 지방간에 운동이 미치는 영향 평가)

  • Kim, Kyoung-Yeon;Lim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • Nonalcoholic fatty liver disease (NAFLD) is accumulation state of fat in liver cells without excessive alcohol intake, and it has been studied that is closely related to obesity. The purpose of this study is to identify risk factors for NAFLD and may prevent or to manage risk factors. This study was in progress for six months (2011 May 1 to October 31), of the 83 people who underwent abdominal ultrasound 11 people eventually were selected. Research results was as follows : First, the decreased body weight and body mass index (BMI), and the second, a decrease of the deepening of fatty liver in ultrasound diagnosis, and the third, steady movement reduces the deepening of fatty liver regardless of calories. Thus, the implication of this research is that long-term exercise programs have positive effects in the treatment of fatty liver.

Association Between Body Mass Index and Breast Density Using Digital Mammography (체질량지수와 디지털유방촬영술상의 유방밀도와의 연관성)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.267-272
    • /
    • 2014
  • It is well known that low body mass index and younger age are associated with high breast density. Mammographic dense breast has been reported both as a cause of false-negative findings on mammography and as an indicator of increased breast cancer risk. The purpose of this study was to evaluate the association between breast density and body mass index. Furthermore, we considered proper screening method of breast cancer in Korean women. The study was performed on 496 women who underwent health checkup in a university hospital. Age and body mass index were negatively associated with breast density respectively. In postmenopausal women, age and body mass index showed statistically significant association with breast density. Therefore, we should consider sensitive additional method for breast cancer screening especially in younger age and underweight women.

Correlation Between High-Sensitive Collimator and Quantitave Analysis in Lung Ventilation SPECT (폐 환기 SPECT에서 고감도 Collimator와 정량분석의 상관관계)

  • Kim, Jung-Soo;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.89-99
    • /
    • 2015
  • This study investigated the correlation between the characteristics of collimator in accordance with the efficiency of detecting photon signals and the quantitative analysis of the lung function, thereby assessing the possibility of clinically applying high sensitivity lung ventilation SPECT. From March to May, 2014, 10 subjects in normal volunteers underwent an ultra high resolution, high resolution and high sensitivity collimator planar scan and SPECT. The experiment showed that compared with the collimator scan, the quantitative analysis results were significant (p=0.89), and compared to the high resolution collimator SPECT, the time was reduced by 4.9 fold. Therefore, the lung ventilation SPECT that had not been used due to an undermined effectiveness can offer usefulness when clinically applied if a high sensitivity collimator is used since the quality and quantity of information and the duration of scan time all offer an improvement.

A Study on the Shielding Element Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 차폐체 원소 평가)

  • Kim, Ki-Jeong;Shim, Jae-Goo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.269-274
    • /
    • 2017
  • In this research, we simulated the elementary star shielding ability using Monte Carlo simulation to apply medical radiation shielding sheet which can replace existing lead. In the selection of elements, mainly elements and metal elements having a large atomic number, which are known to have high shielding performance, recently, various composite materials have improved shielding performance, so that weight reduction, processability, In consideration of activity etc., 21 elements were selected. The simulation tools were utilized Monte Carlo method. As a result of simulating the shielding performance by each element, it was estimated that the shielding ratio is the highest at 98.82% and 98.44% for tungsten and gold.

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Effects of Vaniltic Acid on the Cell Viability and Melanogenesis in Cultured Human Skin Melanoma Cells Damaged by ROS-Induced Cytotoxicity

  • Ha, Dae-Ho;Choi, Yong-Ja;Yoo, Sun-Mi
    • Biomedical Science Letters
    • /
    • v.13 no.4
    • /
    • pp.349-354
    • /
    • 2007
  • The purpose of this study was to examine the effect of vanillic acid on the cell viability and melanogenesis in melanocytes damaged by reactive oxygen species (ROS). The human skin melanoma cells (SK-MEL-3) were cultured with various concentrations of hydrogen peroxide $(H_2O_2)$. The cell viability for $H_2O_2$-induced cytotoxicity or vanillic acid against $H_2O_2$ was measured by XTT assay in these cultures. For the effect of vanillic acid on the melanogenesis, the tyrosinase inhibitory activity was measured by colorimetric assay at a wavelength of 490 nm, and melanin synthesis activity were assessed after cells were cultured in the media with or without various cencentrations of vanillic acid. In this study, $H_2O_2$ decreased cell viability dose- and time-dependent manners and $XTT_{50}$ was determined at a concentration of 80 ${\mu}M$, $H_2O_2$. Vanillic acid increased the cell viability dose dependently in human skin melanoma cells damaged by $H_2O_2$-induced cytotoxicity. In the tyrosinase inhibitory activity, vanillic acid supresssed tyrosinase activity in dosedependent manner, and also decreased significantly melanin synthesis activity compared with $H_2O_2$-treated group. From these results. It is suggested that $H_2O_2$-mediated cytotoxicity was highly by the toxic criteria of Borenfreund and Puerner and also, vanillic acid has the protective effect on ROS-induced cytotoxicity and melanogenesis in these cultures.

  • PDF

Association Between Physical Performance and Bone Mineral Density in Elderly Women (여성 노인에서 운동 수행능력과 골밀도의 관계)

  • Shin, Hwa-Kyung;Cho, Kwang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.37-42
    • /
    • 2009
  • Purpose: The purpose of this study was to determine the effect of physical performance on bone mineral density (BMD) in elderly women. Methods: Twenty-one elderly women participated in this study. After testing functional ambulation category (FAC), they were classified into two groups: dependent walking group, those who could not walk independently (FAC 0~2, n=11) and independent walking group those who could walk independently (FAC 3~5, n=10). Outcome measures were: general characteristics, physical performance and BMD. General characteristics included age, body mass index (BMI) and waist-hip ratio. Physical performance included the chair rise test (CRT) and the modified fall efficacy scale (MFES). BMD was represented in the osteoporosis index (OI), T-score and Z-score. BMD was evaluated in calcaneal bone, using OsteoPro. The data was analyzed using SPSS 12.0 software and the Mann-Whitney U test and the Spearman correlation. Results: Age, BMI and waist hip ratio, which all affect BMD, showed no significant differences between groups (p>0.05). But the FAC 3~5 group showed a significantly higher score for CRT, MFES and T-score, compared with the FAC 0~2 group (p<0.05). The T-score was correlated with CRT and MFES scores (p<0.05). Conclusion: There is a positive relationship between physical performance and BMD. Therefore, improved physical performance can have a beneficial effect by reducing osteoporosis in elderly women, considering a positive relationship between physical performance and BMD.

  • PDF

Satifaction and Improvement of Clinical Experiment of Student Radiotechnologists (대학 방사선학과 학생들의 임상실습에 대한 만족도 현황과 발전방향)

  • Lyu, Kwang-Yeul;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.303-310
    • /
    • 2006
  • Clinical experiment is a set of experience to help student acquire technic, attitude and knowledge by participating in the clinical work. The radiotechnologists who are employed in departments of radiology serve as clinical instructors. Their responsibilities include teaching students them to become competent radiotechnologist. Clinical instructors often have no formal preparation in teaching student. The purpose of this study is to review some principals that will help clinical instructors support and foster the professional development of student radiotechnologists. The clinical instructor should be able to identify the qualities of instructor, the characteristics of feedback and use facillitation skills when is evaluated student performance. And the survey was performed to evaluate the satisfaction of student participated in clinical experiment, the purpose of this research is to fine the problems and improvements in clinical experiment of student radiotechnologist in Korea.

  • PDF

Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro study

  • Abdinian, Mehrdad;Aminian, Maedeh;Seyyedkhamesi, Samad
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • Objectives: Foreign bodies (FBs) account for 3.8% of all pathologies of the head and neck region, and approximately one third of them are missed on initial examination. Thus, FBs represent diagnostic challenges to maxillofacial surgeons, rendering it necessary to employ an appropriate imaging modality in suspected cases. Materials and Methods: In this cross-sectional study, five different materials, including wood, metal, glass, tooth and stone, were prepared in three sizes (0.5, 1, and 2 mm) and placed in three locations (soft tissue, air-filled space and bone surface) within a sheep's head (one day after death) and scanned by panoramic radiography, cone-beam computed tomography (CBCT), and ultrasonography (US) devices. The images were reviewed, and accuracy of the detection modalities was recorded. The data were analyzed statistically using the Kruskal-Wallis, Mann-Whitney U-test, Friedman, Wilcoxon signed-rank and kappa tests (P<0.05). Results: CBCT was more accurate in detection of FBs than panoramic radiography and US (P<0.001). Metal was the most visible FB in all of modalities. US was the most accurate technique for detecting wooden materials, and CBCT was the best modality for detecting all other materials, regardless of size or location (P<0.05). The detection accuracy of US was greater in soft tissue, while both CBCT and panoramic radiography had minimal accuracy in detection of FBs in soft tissue. Conclusion: CBCT was the most accurate detection modality for all the sizes, locations and compositions of FBs, except for the wooden materials. Therefore, we recommend CBCT as the gold standard of imaging for detecting FBs in the maxillofacial region.

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.