• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.039 seconds

A Newborn with Lethal Metatropic Dysplasia (치사성 영양위축성 형성이상 1례)

  • Cho, Hye-Jung;Hwang, Seon-Tae;Lee, Sang-Seon;Kim, Jee-Eun;Jo, Ae-Ran;Shim, So-Yeon;Jeon, In-Sang;Son, Dong-Woo
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.141-146
    • /
    • 2010
  • Metatropic dysplasia is a rare spondylo epi metaphyseal dysplasia characterized by progressive kyphoscoliosis, short limbs with relatively large hands and feet and limited of motion and enlargement of the large joints. It is diagnosed based on the characteristic clinical and radiological features. Even though benign cases of this disease are frequently reported, metatropic dysplasia can often have a fatal outcome. We describe a sporadic case of the well-delineated lethal metatropic dysplasia.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Citation Trend and Suggestions for Improvement of Impact Factor of Journal of Korean Therapeutic Radiology and Oncology (대한방사선종양학회지의 학술인용 변화 추이 및 학술 영향력 지수 개선을 위한 제안: 한국의학학술지 인용색인 자료 분석)

  • Kim, Seong-Hwan;Ahn, Myeong-Im;Jeong, So-Na;Hwang, Seong-Su
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.309-316
    • /
    • 2006
  • $\underline{Purpose}$: To analyze the recent citation trend and to find a way to improve impact factor (IF) of the Journal of Korean Therapeutic Radiology and Oncology (JKSTRO) by analysis of Korean Medical Citation Index (KoMCI) citation data of JKSTRO and comparison with that of mean citation data of all journals enlisted on KoMCI (KoMCI journals) during 2000-2005. $\underline{Materials\;and\;Methods}$: All citation data of entire journals enlisted on KoMCI and JKSTRO from 2000 to 2005 were obtained from KoMCI. The trend of total and annual number of published articles and reference citations, total citations and self-citations per paper, IF and impact factor excluding self-citations (ZIF) were described and compared on both KoMCI journals and JKSTRO. $\underline{Results}$: Annual number of published articles was decreased for 6 years on both KoMCI journals and JKSTRO (32% and 38% reduction rate). The number of Korean journal references per article is 1.6 papers on JKSTRO comparing to 2.0 papers on KoMCI journals. The percentage of Korean references/total references increased from 5.0% in 2000 to 7.7% in 2005 on JKSTRO and from 8.5% in 2000 to 10.1% on KoMCI journals. The number of total citations received/paper on JKSTRO (average 1.333) is smaller than that of KoMCI journals (average 1.694), there was an increased rate of 67% in 2005 comparing to 2000. The percentage of self-citations/total citations (average 72%) on JKSTRO is slightly higher than that of KoMCI journals (average 61%). IF of JKSTRO was gradually improved and 0.144, 0.125, 0.088, 0.107, 0.187, and 0.203 in 2000-2005 respectively. However, ZIF of JKSTRO is steadily decreased from 0.038 in 2000 to 0.013 in 2005 except 0.044 in 2004. $\underline{Conclusion}$: IF of JKSTRO was slightly improved but had some innate problem of smaller number of citations received. To make JKSTRO as a highly cited journal, the awareness of academic status of JKSTRO and active participation of every member of JKSTRO including encouraging self-citations of papers published recent 2 years and submission of English written papers, and active academic cooperation with related academic societies.

Altered Nurr1 protein expression in the hippocampal CA1 region following transient global cerebral ischemia

  • Joon Ha Park;Ji Hyeon Ahn;Dae Won Kim;Tae‑Kyeong Lee;Cheol Woo Park;Young Eun Park;Jae‑Chul Lee;Hyang‑Ah Lee;Go Eun Yang;Moo‑Ho Won;Choong‑Hyun Lee
    • Molecular Medicine Reports
    • /
    • v.21 no.1
    • /
    • pp.107-114
    • /
    • 2020
  • Nuclear receptor related 1 protein (Nurr1), a member of the nuclear receptor 4 family of orphan nuclear receptors, has been reported to display anti-inflammatory properties. The present study investigated the alteration of Nurr1 immunoreactivity in the gerbil hippocampus proper following 5 min of transient global cerebral ischemia. In sham operated gerbils, Nurr1 immunoreactivity was observed in pyramidal neurons in all cornu ammonis 1-3 (CA1-3) subfields of the hippocampus proper. In ischemia-operated gerbils, Nurr1 immunoreactivity was altered in the CA1 subfield. Nurr1 immunoreactivity in CA1 pyramidal neurons gradually decreased until 2 days post-ischemia, and, at 4 days post-ischemia, Nurr1 immunoreactivity was concentrated in CA1 pyramidal neurons. Additionally, Nurr1 immunoreactivity was newly expressed in microglia in the CA1 subfield at 4 days post-ischemia. Conversely, in the CA2/3 subfield, time-dependent alteration of Nurr1 immunoreactivity was not identified at any time following ischemia. These results indicated that the alteration of Nurr1 expression in the CA1 subfield in the hippocampus may be associated with the death of CA1 pyramidal neurons.

Conceptus-related measurements at early pregnancy in Black Bengal goat: an abattoir study

  • Talukder, Anup K.;Rahman, Mohammad A.;Hoque, Mohammad N.;Islam, Mohammad T.;Rahman, Abu N.M.A.;Das, Ziban C.
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.2
    • /
    • pp.177-182
    • /
    • 2020
  • The present study aimed to investigate the conceptus-related changes during early pregnancy in the Black Bengal breed of goat. A total of 22 gravid genitalia of the Black Bengal goats were collected from local slaughterhouses. The crown-rump lengths (CRL) of the conceptuses were determined to estimate the gestational age (GA). The length and diameter of uterine horn and amniotic sac were measured, and volume of amniotic and allantoic fluid formed by individual conceptus were recorded. The results reveal that the CRL is positively correlated with GA of the conceptus (R2 = 0.89, p < 0.05); however, CRL was not influenced by number of conceptus. Both the left and the right uterine horn gradually increased in size with the advancement of pregnancy irrespective of conceptus number present in the horn. The size of the amniotic sac of conceptus gradually increased with the conceptus age but maintained spherical shape from 5 to 7 weeks of pregnancy. The amniotic fluid formed by individual conceptus rapidly increased from 5 weeks (3.4 ± 0.3 mL) to 7 weeks (21.0 ± 2.0 mL) and 9 weeks (111.5 ± 4.0 mL). The volume of allantoic fluid formed by individual conceptus was steadily increased until 7 weeks (60.0 ± 5.0 mL) and began to decline slowly thereafter (50.0 ± 5.0 mL at 9 weeks). Notably, there was no effect of conceptus number per pregnancy on individual amniotic and allantoic fluid volume. The cotyledons have first appeared on the allanto-chorionic surface from 4 to 5 weeks of pregnancy. The closed eye, nostril and hooves of the conceptus became visible at 7 weeks of pregnancy. The present study has shown the basic information on conceptus-related developmental changes during early pregnancy up to 9 weeks in Black Bengal goat.

Comparative Analysis of Endovascular Stroke Therapy Using Urokinase, Penumbra System and Retrievable (Solitare) Stent

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.5
    • /
    • pp.342-349
    • /
    • 2015
  • Background : Higher reperfusion rates have been established with endovascular treatment for acute ischemic stroke patients. There are limited data on the comparative performance of mechanical thrombectomy devices. This study aimed to analyse the efficacy and safety of the stent retriever device (Solitaire stent) by comparing procedure time, angiographic outcome, complication rate and long term clinical outcome with previous chemical thrombolysis and mechanical thrombectomy using penumbra system. Method : A retrospective single-center analysis was undertaken of all consecutive patients who underwent chemical thrombolysis and mechanical thrombectomy using Penumbra or Solitaire stent retriever from March 2009 to March 2014. Baseline characteristics, rate of successful recanalization (modified Thrombolysis in Cerebral Infarction score 2b-3), symptomatic intracerebral hemorrhage, procedure time, mortality and independent functional outcomes ($mRS{\leq}2$) at 3 month were compared across the three method. Results : Our cohort included 164 patients, mechanical thrombectomy using stent retriever device had a significant impact on recanalization rate and functional independence at 3 months. In unadjusted analysis mechanical thrombectomy using Solitaire stent retriever showed higher recanalization rate than Penumbra system and chemical thrombolysis (75% vs. 64.2% vs. 49.4%, p=0.03) and higher rate of functional independence at 3 month (53.1% vs. 37.7% vs. 35.4%, p=0.213). In view of the interrelationships between all predictors of variables associated with a good clinical outcome, when the chemical thrombolysis was used as a reference, in multiple logistic regression analysis, the use of Solitaire stent retriever showed higher odds of independent functional outcome [odds ratio (OR) 2.62, 95% confidence interval (CI) 0.96-7.17; p=0.061] in comparison with penumbra system (OR 1.57, 95% CI 0.63-3.90; p=0.331). Conclusion : Our initial data suggest that mechanical thrombectomy using stent retriever is superior to the mechanical thrombectomy using penumbra system and conventional chemical thrombolysis in achieving higher rates of reperfusion and better outcomes. Randomized clinical trials are needed to establish the actual benefit to specific patient populations.

Direct Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Objective : Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filters during CAS. Methods : A total of 107 patients underwent CAS with use of a distal protection filter. Angiographic carotid plaque surface morphology was classified as smooth, irregular, and ulcerated. To determine predictable factors of filling defect in the protection filters, 11 variables were retrospectively analyzed which might influence filling defect in the protection filters during CAS. Results : Filling defects during CAS were presented in the 33 cerebral protection filters. In multivariate analysis, angiographic ulceration [odds ratio (OR), 6.60; 95% confidence interval (CI) : 2.24, 19.4; p=0.001], higher stenosis degree (OR, 1.06; 95% CI : 1.00, 1.12; p=0.039), and coexistent thrombus (OR, 7.58; 95% CI : 1.69, 34.05; p=0.08) were highly associated with filling defect in the cerebral protection devices during CAS. Among several variables, angiographic surface ulceration was the only significant factor associated with flow stagnation during CAS (OR, 4.11; 95% CI : 1.33, 12.72; p=0.014). Conclusion : Plaque surface morphology on carotid angiography can be a highly sensitive marker of plaque instability during CAS. The independent risk factors for filling defect in the filter devices during CAS were plaque ulceration, stenosis degree, and coexistent thrombus.

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF