Development and Application of Case-Based Learning Program for Occupational Personality Education of Health Care Worker (보건의료종사자 맞춤형 직업인성교육을 위한 사례기반학습 프로그램 개발 및 적용)

  • Yang, Eun Ju;Kim, Hye Ran;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.371-379
    • /
    • 2021
  • The personality education of the existing university is mainly focused on occupational ethics education or basic education, but the purpose and method of the personality education program is changed in preparation for the 4th industry and the related occupational personality education program is needed. In Korea, however, there is a lack of research on the development of educational programs for occupational personalities that Health care workers should have. Therefore, this study aims to confirm the effect by developing and applying a program for occupational personality education for Health care workers required for the 4th Industrial Revolution based on case-based learning. In this study, general cases and occupational cases were developed, and research tools were developed to verify the effectiveness of the occupational personality education program. The program developed in this study was provided four times for 52 students in the second and third grades college and university. This study was performed with a single group pre-post design. The data were analyzed by means of mean, standard deviation, and paired t-test. By applying the program developed in this study, accountability, honesty, consideration, collaboration, communication, and competency were improved. This confirmed the positive effect of vocational character education

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

Analysis of Changes in Carotid Intima-media Thicknesses according to Metabolic Syndrome-inducing Factors (대사증후군 유발 인자에 따른 경동맥 내중막 두께의 변화 분석)

  • Nan-Hee An;Tae-Jeong Ji;Hyeon-Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.597-606
    • /
    • 2023
  • This study retrospectively analyzed the test results of 235 patients who visited a medical institution in Busan from May 2022 and February 2023 and conducted both carotid ultrasonography and blood tests. The purpose of this study was to investigate the effect on intima-media thickness and blood flow velocity by measuring the intima-media thickness and blood flow velocity through carotid ultrasonography and analyzing the factors influencing the subject's body mass index and metabolic syndrome. Correlation analysis between carotid intima-media thickness and body mass showed (p=0.000) confirming that there is a correlation. As a result Correlation analysis between blood flow velocity and body mass index (p=0.015) was found, comfirming that there was a correlation. Age (p= 0.000), fasting blood glucose (p=0.002) and alcohol consumption (p=0.006) were found to be correlated with carotid intima-media thickness. An increase in Carotid intima-media thicknesses causes an increase in events caused by cardiovascular disease. Therefore, efforts must be made to exclude factors that increase Carotid intima-media thicknesses, and it will be most important to prevent cardiovascular disease through research on various prediction methods and regular checkups.

Evaluation of Metal Composite Filaments for 3D Printing (3D 프린팅용 금속 입자 필라멘트의 물성 및 차폐 능력 평가)

  • Park, Ki-Seok;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.697-704
    • /
    • 2021
  • It is hard to get Filaments which are materials of the 3D printing Fused Deposition Modeling(FDM) method as radiation shielding in Korea. and also related research is insufficient. This study aims to provide basic data for the development of radiation shields using 3D printing by evaluating the physical properties and radiation shielding capabilities of filaments containing metal particles. after selecting five metal filaments containing metal particle reinforcement materials, the radiation shielding rate was calculated according to the Korean Industrial Standard's protective equipment test method to evaluate physical properties such as tensile strength, density, X-ray Diffraction(XRD), and weight measurement using ASTM's evaluation method. In the tensile strength evaluation, PLA + SS was the highest, ABS + W was the lowest, and ABS + W is 3.13 g/cm3 which value was the highest among the composite filaments in the density evaluation. As a result of the XRD, it may be confirmed that the XRD peak pattern of the particles on the surface of the specimen coincides with the pattern of each particle reinforcing material powder metal, and thus it was confirmed that the printed specimen contained powder metal. The shielding effect for each 3D printed composite filament was found to have a high shielding rate in proportion to the effective atomic number and density in the order of ABS + W, ABS + Bi, PLA+SS, PLA + Cu, and PLA + Al. In this study, it was confirmed that the metal particle composite filament containing metal powder as a reinforcing material has radiation shielding ability, and the possibility of using a radiation shielding filament in the future.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

Evaluation of the usefulness of Images according to Reconstruction Techniques in Pediatric Chest CT (소아 흉부 CT 검사에서 재구성 기법에 따른 영상의 유용성 평가)

  • Gu Kim;Jong Hyeok Kwak;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.285-295
    • /
    • 2023
  • With the development of technology, efforts to reduce the exposure dose received by patients in CT scans are continuing with the development of new reconstruction techniques. Recently, deep learning reconstruction techniques have been developed to overcome the limitations of repetitive reconstruction techniques. This study aims to evaluate the usefulness of images according to reconstruction techniques in pediatric chest CT images. Patient study conducted a study on 85 pediatric patients who underwent chest CT scan at P-Hospital in Gyeongsangnam-do from January 1, 2021 to December 31, 2022. The phantom used in the Phantom Study is the Pediatrics Whole Body Phantom PBU-70. After the test, the images were reconstructed with FBP, ASIR-V (50%) and DLIR (TF-Medium, High), and the images were evaluated by obtaining SNR and CNR values by setting ROI of the same size. As a result, TF-H of deep learning reconstruction techniques had the lowest noise value compared to ASIR-V (50%) and TF-M in all experiments, and SNR and CNR had the highest values. In pediatric chest CT scans, TF images with deep learning reconstruction techniques were less noisy than ASiR-V images with adaptive statistical iterative reconstruction techniques, CNR and SNR were higher, and the quality of images was improved compared to conventional reconstruction techniques.

Analysis of Tissue Equivalent Characteristics of Agar Phantom for Hyperthermia Therapy (온열종양치료 한천 팬텀의 조직등가 특성 분석)

  • Jeong-Geun Park;Kyeong-Hwan Jeong;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.985-991
    • /
    • 2023
  • A tissue-equivalent phantom is necessary for quality control of hyperthermia therapy. However, since there is no phantom for this purpose, phantoms made from agar are being used in various studies. The tissue-equivalent properties of the agar phantom were confirmed by comparison with the tissue-equivalent material bolus in this study. CT images of the agar phantom and bolus were acquired, and tissue equivalent characteristics were analyzed with image analysis and dose calculation using a computerized radiation therapy planning system. The average pixel value was 96.960±10.999 in bolus, 108.559±8.233 in 3% agar phantom, and 111.844±8.651 in 4% agar phantom. Using the SSD technique, 100 cGy was prescribed at a depth of 1.5 cm and 6 MV X -ray was set to irradiated to 10x10 cm2, and the absorbed dose according to depth was calculated from the central axis of the beam. The intraclass correlation coefficient of dose distribution of bolus, 3% agar phantom, and 4% agar phantom was 0.979 (p<.001, 95%CI .957-.991). The density (g/cm3) at the point where the absorbed dose was calculated was 0.990±0.020 at the bolus, 1.018±0.020 at the 3% agar phantom, and 1.035±0.024 at the 4% agar phantom. In this study, the internal density distribution and uniformity of the agar phantom were confirmed to be appropriate as a tissue equivalent material by analysis of CT images and a computerized radiation therapy planning system.

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.

Analysis of Observer Agreement in Shear Wave Elastography using a Breast Phantom (유방 팬텀을 활용한 전단파 탄성초음파 검사에서의 관측자 일치도 분석)

  • Jin-Hee Kim;Jung-Hoon Kim;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.355-363
    • /
    • 2024
  • This study evaluated the clinical utility of Shear Wave Elastography(SWE) by analyzing the differences in elastic modulus and shear wave speed across various types of breast tissue and assessing inter-observer agreement. A breast phantom that included normal breast tissue, benign tumors, and malignant tumors was utilized, and ten radiologists participated, measuring the minimum, average, and maximum elastic modulus and shear wave speed for each tissue type. Analysis of differences between tissues was conducted using one-way ANOVA, and intra- and inter-observer agreement was assessed using the Intraclass Correlation Coefficient(ICC). The results demonstrated significant differences in the average values of elastic modulus and shear wave speed among the tissue types(p<0.001), with malignant tumor tissues showing the highest average values. Furthermore, the ICC analysis for elastic modulus ranged from 0.75 to 0.99 and for shear wave speed from 0.89 to 0.99, indicating high reproducibility and agreement. These findings suggest that SWE is a reliable tool with high reproducibility and specificity for the diagnosis of breast cancer.

Analysis of Thyroid Nodule Prevalence and Related Factors in Adult Men and Women (성인 남녀에서 갑상선결절 유병률과 관련 인자 분석)

  • Ye-Eun Oh;Jung-Hoon Kim;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.373-381
    • /
    • 2024
  • This study aimed to identify and assess the influence of risk factors on the frequency of thyroid nodules diagnosed through ultrasonography among adults visiting for health screenings. The study analyzed 210 adult men and women who underwent thyroid ultrasound at J Hospital in Busan. The differences in variables were analyzed using Chi-square and independent t-tests, and risk ratios were calculated using binary logistic regression. The results showed significant differences in gender, age, T3, Free T4, Uric acid, T-chol, HDL-C and LDL-C. The risk ratios for risk factors indicated that women had a 2.42 times higher risk compared to men, and the age groups 41-50 and over 61 had risks 2.32 and 2.22 times higher, respectively compared to those under 40. Conversely, and increase in T3 and Free T4 levels was associated with a decreased risk of 0.12 and 0.86 times, respectively, while lipid levels had negligible influence. Based on these findings, it is concluded that regular ultrasonography monitoring, rather than solely relying on biochemical markers, is crucial for the early detection and management of thyroid nodules.