• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

Root surface areas of maxillary permanent teeth in anterior normal overbite and anterior open bite assessed using cone-beam computed tomography

  • Suteerapongpun, Piyadanai;Sirabanchongkran, Supassara;Wattanachai, Tanapan;Sriwilas, Patiyut;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.241-246
    • /
    • 2017
  • Purpose: The aim of this study was to compare the root surface areas of the maxillary permanent teeth in Thai patients exhibiting anterior normal overbite and in those exhibiting anterior open bite, using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of maxillary permanent teeth from 15 patients with anterior normal overbite and 18 patients with anterior open bite were selected. Three-dimensional tooth models were constructed using Mimics Research version 17.0. The cementoenamel junction was marked manually. The root surface area was calculated automatically by 3-Matic Research version 9.0. The root surface areas of each tooth type from both types of bite were compared using the independent t-test (P<.05). The intraclass correlation coefficient was used to assess intraobserver reliability. Results: The mean root surface areas of the maxillary central and lateral incisors in individuals with anterior open bite were significantly less than those in those with normal bite. The mean root surface area of the maxillary second premolar in individuals with anterior open bite was significantly greater than in those with normal bite. Conclusion: Anterior open-bite malocclusion might affect the root surface area, so orthodontic force magnitudes should be carefully determined.

Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden

  • Park, Sa-Beom;An, So-Youn;Han, Won-Jeong;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.154-164
    • /
    • 2017
  • Purpose: Measurement of the root surface area (RSA) is important in periodontal treatment and for the evaluation of periodontal disease as a risk factor for systemic disease. The aim of this study was to measure the RSA at 6 mm below the cementoenamel junction (CEJ) using the Mimics software (Materialise, Leuven, Belgium). Methods: We obtained cone-beam computed tomography (CBCT) data from 33 patients who had visited the Department of Oral and Maxillofacial Radiology of Dankook University Dental Hospital. The patients comprised 17 men and 16 women aged from 20 to 35 years, with a mean age of 24.4 years. Only morphologically intact teeth were included in our data. Because the third molars of the maxilla and mandible have a high deformation rate and were absent in some participants, they were not included in our research material. Results: The CBCT data were reconstructed into 3-dimensional (3D) teeth models using the Mimics software, and the RSA at 6 mm below the CEJ was separated and measured using 3-Matic (Materialise). In total, 924 3D teeth models were created, and the area at 6 mm below the CEJ could be isolated in all the models. The area at 6 mm below the CEJ was measured in all teeth from the 33 patients and compared based on sex and position (maxilla vs. mandible). Conclusions: In this study, we demonstrated that it was feasible to generate 3D data and to evaluate RSA values using CBCT and the Mimics software. These results provide deeper insights into the relationship between periodontal inflammatory burden and systemic diseases.

Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography

  • Rosado, Lucas de Paula Lopes;Barbosa, Izabele Sales;de Aquino, Sibele Nascimento;Junqueira, Rafael Binato;Verner, Francielle Silvestre
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • Purpose: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs(PR) and cone-beam computed tomography (CBCT). Materials and Methods: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. Results: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial(0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better(P<0.05). Conclusion: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Cricopharyngeal achalasia in an old dog

  • Im, Ji-Eun;Yoon, Hun-Young;Kim, Seung-Gon;Lee, Chang-Min;Eom, Ki-Dong;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.4
    • /
    • pp.261-263
    • /
    • 2014
  • A 10-year-old castrated male papillon presented with nasal discharge, coughing and chronic dysphagia. On physical examination, the dog exhibited sneezing, gurgling and movement of the throat with repeated attempts to swallow fluids. A diagnosis of cricopharyngeal achalasia (CPA) was made based on video fluoroscopic demonstration of failure of relaxation of the upper esophageal sphincter. This report describes the diagnosis of CPA in an old dog, which is rarely diagnosed in older animals.

Solitary peripheral osteomas of the jaws

  • Franca, Talita Ribeiro Tenorio De;Gueiros, Luiz Alcino Monteiro;Castro, Jurema Freire Lisboa De;Catunda, Ivson;Leao, Jair Carneiro;Perez, Danyel Elias Da Cruz
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.99-103
    • /
    • 2012
  • Osteoma is a benign osteogenic tumor composed of cancellous or compact bone, classified as peripheral, central, or extraskeletal. Peripheral osteomas are uncommon. Excluding the maxillary sinuses, the maxilla is a rare site for osteomas. The purpose of this report was to describe clinicopathological and radiological features of two peripheral osteomas occurring in the jaws, one located in the mandible and another in the edentulous maxillary alveolar ridge. The tumors were asymptomatic and were fully excised without any complications or recurrence. The lesions were submitted to histopathological analysis and diagnosed as peripheral osteoma, compact type.

Radiographic analysis of the management of tooth extractions in head and neck-irradiated patients: a case series

  • Oliveira, Samanta V.;Vellei, Renata S.;Heguedusch, Daniele;Domaneschi, Carina;Costa, Claudio;Gallo, Camila de Barros
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.323-328
    • /
    • 2021
  • Tooth extraction after head and neck radiotherapy exposes patients to an increased risk for osteoradionecrosis of the jaw. This study reports the results of a radiographic analysis of bone neoformation after tooth extraction in a case series of patients who underwent radiation therapy. No patients developed osteoradionecrosis within a follow-up of 1 year. Complete mucosal repair was observed 30 days after surgery, while no sign of bone formation was observed 2 months after the dental extractions. Pixel intensity and fractal dimension image analyses only showed significant bone formation 12 months after the tooth extractions. These surgical procedures must follow a strict protocol that includes antibiotic prophylaxis and therapy and complete wound closure, since bone formation at the alveolar socket occurs at a slower pace in patients who have undergone head and neck radiotherapy.

Autofluorescence Loss in Photobleaching for Human Dentin ex vivo

  • Lee, Seunghwan Goldmund;Kim, Minwoo;Jeong, Sunghee;Hwang, Jaejoon;Kim, Jisu;Gourrier, Aurelien;Vial, Jean Claude;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.86-91
    • /
    • 2022
  • Two-photon fluorescence microscopy was performed on the enamel-dentin junction area of a human tooth using a femtosecond pulsed laser. We obtained a clear image contrast between the bright dentin and dark tubules with the autofluorescence generated from the endogenous fluorophores in dentin. The autofluorescence shows a broad spectrum due to complex cross links between dentinal collagens, which extend from blue to orange wavelengths (470-590 nm), but a gradual autofluorescence loss in photobleaching was observed for a long-term exposure under strong excitation. For increasing excitation power, we found that two-step decay becomes significant in the spectrally integrated autofluorescence.

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.