• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

MRI-Based Stepwise Approach to Anterior Mediastinal Cystic Lesions for Diagnosis and Further Management

  • Jong Hee Kim;Jooae Choe;Hong Kwan Kim;Ho Yun Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.1
    • /
    • pp.62-78
    • /
    • 2023
  • As the majority of incidentally detected lesions in the anterior mediastinum is small nodules with soft tissue appearance, the differential diagnosis has typically included thymic neoplasm and prevascular lymph node, with benign cyst. Overestimation or misinterpretation of these lesions can lead to unnecessary surgery for ultimately benign conditions. Diagnosing mediastinal cysts using MRI serves as a problem-solving modality in distinguishing between surgical and nonsurgical anterior mediastinal lesions. The pitfalls of MRI evaluation for anterior mediastinal cystic lesions are as follows: first, we acknowledge the limitation of T2-weighted images for evaluating benign cystic lesions. Due to variable contents within benign cystic lesions, such as hemorrhage, T2 signal intensity may be variable. Second, owing to extensive necrosis and cystic changes, the T2 shine-through effect may be seen on diffusion-weighted images (DWI), and small solid portions might be missed on enhanced images. Therefore, both enhancement and DWI with apparent diffusion coefficient values should be considered. An algorithm will be suggested for the diagnostic evaluation of anterior mediastinal cystic lesions, and finally, a management strategy based on MRI features will be suggested.

A Case Report of Cholangiocarcinoma Arising from a Biliary Adenofibroma: Radiologic Findings and Review of Literature (담도선섬유종에서 발생한 담관암: 증례 보고 및 문헌적 고찰)

  • Hyun-Ji Lim;Mi-Suk Park;Young Nyun Park;Sun Il Kim;Yeo-Eun Kim;Cheong Hoon Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.721-728
    • /
    • 2021
  • Biliary adenofibromas are rare biliary epithelial tumors that are classified as benign. Nevertheless, some cases have been reported to show malignant transformations. The radiologic findings of biliary adenofibromas and their malignant transformation are not well-established because of their rarity. We present a case of a cholangiocarcinoma arising from a biliary adenofibroma assessed using ultrasonography, CT, and MRI. The differential diagnoses include other hepatic tumors.

Updated Primer on Generative Artificial Intelligence and Large Language Models in Medical Imaging for Medical Professionals

  • Kiduk Kim;Kyungjin Cho;Ryoungwoo Jang;Sunggu Kyung;Soyoung Lee;Sungwon Ham;Edward Choi;Gil-Sun Hong;Namkug Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.224-242
    • /
    • 2024
  • The emergence of Chat Generative Pre-trained Transformer (ChatGPT), a chatbot developed by OpenAI, has garnered interest in the application of generative artificial intelligence (AI) models in the medical field. This review summarizes different generative AI models and their potential applications in the field of medicine and explores the evolving landscape of Generative Adversarial Networks and diffusion models since the introduction of generative AI models. These models have made valuable contributions to the field of radiology. Furthermore, this review also explores the significance of synthetic data in addressing privacy concerns and augmenting data diversity and quality within the medical domain, in addition to emphasizing the role of inversion in the investigation of generative models and outlining an approach to replicate this process. We provide an overview of Large Language Models, such as GPTs and bidirectional encoder representations (BERTs), that focus on prominent representatives and discuss recent initiatives involving language-vision models in radiology, including innovative large language and vision assistant for biomedicine (LLaVa-Med), to illustrate their practical application. This comprehensive review offers insights into the wide-ranging applications of generative AI models in clinical research and emphasizes their transformative potential.

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

Assessment of the Eye Lens Dose Reduction by Bismuth Shields in Rando Phantom Undergoing CT of the Head (Head CT 검사 시 안구 차폐용 Bismuth사용에 의한 수정체 선량 감소에 대한 평가)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, In-Ja;Chang, Sang-Gyu;Chung, Jung-Pyo;Lee, Hyun;Kim, Jang-Seob;Shin, Dong-Cheol;Choi, Jong-Hak;Lee, Ki-Sung;Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.171-175
    • /
    • 2008
  • The aim of this study is to assess the dose reduction of eye lens and availability of bismuth garments resulting from the use of radioprotective bismuth garments to shield the eyes of patients undergoing head CT. Rando phantom and TLDs were used to determine the amount of dose reduction by bismuth shielding of the eye in the following simulated CT scans : (a) scanning of the head including orbits, (b) scanning of the whole head, and (c) $20^{\circ}$ angled scanning of the head excluding orbits. The average dose reduction of eye lens was 43.2%, 36.0% and 1.4% for the three CT scans listed above. Significant reduction in the eye lens dose was achieved by using superficial orbital bismuth shielding during head CT scans. However, bismuth shields should not be used for the patients when their eyes are excluded from the primarily exposed region.

  • PDF

Current Status of Etiology, Epidemiology, Clinical Manifestations and Imagings for COVID-19

  • Meng Di Jiang;Zi Yue Zu;U. Joseph Schoepf;Rock H. Savage;Xiao Lei Zhang;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1138-1149
    • /
    • 2020
  • Coronavirus disease 2019 (COVID-19) is a transmissible respiratory disease that was initially reported in Wuhan, China in December 2019. With the alarming levels of COVID-19 spread worldwide, the World Health Organization characterized COVID-19 as a pandemic. Over the past several months, chest CT has played a vital role in early identification, disease severity assessment, and dynamic disease course monitoring of COVID-19. The published data has enriched our knowledge on the etiology, epidemiology, clinical manifestations, and pathologic findings of COVID-19. Additionally, as the imaging spectrum of the disease continues to be defined, extrapulmonary infections or other complications will require further attention. This review aims to provide an updated framework and essential knowledge with which radiologists can better understand COVID-19.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Influence of mesiodens on adjacent teeth and the timing of its safe removal

  • Barham, Majd;Okada, Shunsuke;Hisatomi, Miki;Khasawneh, Abdullah;Tekiki, Nouha;Takeshita, Yohei;Kawazu, Toshiyuki;Fujita, Mariko;Yanagi, Yoshinobu;Asaumi, Junichi
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.67-74
    • /
    • 2022
  • Purpose: To focus on the effects of the presence of mesiodens on adjacent teeth and to investigate the timing of its safe removal. Materials and Methods: Cone-beam computed tomography examinations, obtained at Okayama University Hospital over a three-year period, were inspected. Data were recorded including the number of mesiodens; associated abnormalities; and the relationship with neighboring structures. Depending on multiple factors, the risk of developing complications due to early extraction of a mesiodens was divided into three categories: high, medium, and low risk. Results: A total of 5,958 cone-beam computed tomography exams were obtained, 460 patients aged 3-85 years were diagnosed with a total of 568 mesiodens, 382 (67.3%) of which were discovered in young patients (age <10 years), and 333 (87.2%) of these were associated with abnormalities. Regarding the risk categories, 11 (1.9%) were considered to be in the high-risk, five (0.9%) in the medium-risk and 552 (97.2%) in the low-risk categories. Moreover, eight out of 11 high-risk mesiodens were extracted and no post-operative complications have been seen. Conclusion: As the results showed that no postoperative complications were seen in all the extracted cases of high-risk mesiodens, this indicates the possibility of safe extraction at an early age which could reduce related future complications.

Quantitative MRI Assessment of Pancreatic Steatosis Using Proton Density Fat Fraction in Pediatric Obesity

  • Jisoo Kim;Salman S. Albakheet;Kyunghwa Han;Haesung Yoon;Mi-Jung Lee;Hong Koh;Seung Kim;Junghwan Suh;Seok Joo Han;Kyong Ihn;Hyun Joo Shin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1886-1893
    • /
    • 2021
  • Objective: To assess the feasibility of quantitatively assessing pancreatic steatosis using magnetic resonance imaging (MRI) and its correlation with obesity and metabolic risk factors in pediatric patients. Materials and Methods: Pediatric patients (≤ 18 years) who underwent liver fat quantification MRI between January 2016 and June 2019 were retrospectively included and divided into the obesity and control groups. Pancreatic proton density fat fraction (P-PDFF) was measured as the average value for three circular regions of interest (ROIs) drawn in the pancreatic head, body, and tail. Age, weight, laboratory results, and mean liver MRI values including liver PDFF (L-PDFF), stiffness on MR elastography, and T2* values were assessed for their correlation with P-PDFF using linear regression analysis. The associations between P-PDFF and metabolic risk factors, including obesity, hypertension, diabetes mellitus (DM), and dyslipidemia, were assessed using logistic regression analysis. Results: A total of 172 patients (male:female = 125:47; mean ± standard deviation [SD], 13.2 ± 3.1 years) were included. The mean P-PDFF was significantly higher in the obesity group than in the control group (mean ± SD, 4.2 ± 2.5% vs. 3.4 ± 2.4%; p = 0.037). L-PDFF and liver stiffness values showed no significant correlation with P-PDFF (p = 0.235 and p = 0.567, respectively). P-PDFF was significantly associated with obesity (odds ratio 1.146, 95% confidence interval 1.006-1.307, p = 0.041), but there was no significant association with hypertension, DM, and dyslipidemia. Conclusion: MRI can be used to quantitatively measure pancreatic steatosis in children. P-PDFF is significantly associated with obesity in pediatric patients.