• Title/Summary/Keyword: Radiology Department

Search Result 9,251, Processing Time 0.043 seconds

Effects of Reduced Glutathione and Ginseng Extract on Non-Protein Sulfhydryl, and Non-Protein Disulfide of Mouse Liver and Blood Following Whole Body X-Irradiation (Reduced glutathione 및 인삼추출액(人蔘抽出液)이 X-선전신조사(線全身照射)를 입은 마우스 간조직(肝組織) 및 혈중(血中) NP-SH 및 NP-SS에 미치는 영향(影響))

  • Oh, Jang-Suk
    • The Korean Journal of Physiology
    • /
    • v.6 no.2
    • /
    • pp.57-63
    • /
    • 1972
  • In an attempt to better understand the radioprotective effect of reduced glutathione(GSH), and to observe a possible radioprotective effect of Ginseng extract, whole body X-irradiation of 1,200 r was administered to the mouse either independently or immediately following the injection of GSH or Ginseng extract to the mouse intraperitoneally. The non-protein sulfhydryl (NP-SH) and non-protein disulfide (NP-SS) levels of the liver, and NP-SH level of NP-SH of the blood of the mouse were measured at 30, 60 and 120 minutes, and results were compared with the normal. The results thus obtained are summarized as follows; 1) The normal values of NP-SH and NP-SS of the mouse liver were $5.90{\pm}0.46\;{\mu}\;mol/gm\;wet\;wt.,\;and\;3.02{\pm}0.42\;{\mu}\;mol/ml$ wet wt., respectively, and the normal value of NP-SH of NP-SH of the mouse blood was $3.98{\pm}1.29\;{\mu}\;mol/ml$ 2) The injection of both GSH and Ginseng extract produced the highest values of NP-SH in the liver at 30 minutes, but a gradual decrease to the normal was observed thereafter. When X-irradiation alone was applied, the liver NP-SH value was lower than the normal at 60 minutes post-irradiation and thereafter. When Ginseng extract was injected immediately prior to X-irradiation, the liver NP-SH was lower than the normal throughout the experiment with the lowest value at 60 minutes. However, the combination of GSH and X-irradiation produced higher than the normal values throughout the entire experiment. 3) The liver NP-SS value was most significantly elevated at 30 minutes after the injection of GSH, hut the recovery to the normal was observed thereafter. The injection of Ginseng extract produced slightly higher liver NP-SS values at 30 and 60 minutes, but the value at 120 minutes was similar to the normal. The single application of X-irradiation resulted in the lower then normal liver NP-SS values throughout the entire experiment. When GSH was injected price to X-irradiation, the liver NP-SS values were higher than the normal at 30 and 60 minutes followed b the recovery to the normal at 120 minutes. The combination of Ginseng extract and X-irradiation showed generally lower liver NP-SS values throughout the experiment. 4) The blood NP-SH showed the higher than the normal values in all the experimental groups except when GSH was injected prior to X-irradiation alone produced e significantly elevated blood NP-SS value at 30 minutes post-irradiation.

  • PDF

Initial Diagnosis of Acute Renal Failure Induced by Ischemia in Miniature Pig (미니돼지에서 허혈성 신장 손상의 조기진단)

  • Kim, Se-Eun;Ko, A-Ra;Bae, Chun-Sik;Park, Soo-Hyun;Han, Ho-Jae;Shim, Kyung-Mi;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • Acute renal injury induced by ischemia is a major cause of high morbidity and mortality in hospitalized patients and a common complication in hospitalized patients. Thus, the work with acute renal failure and renal ischemia has been studied for many years. Although serum creatinine concentration that is widely used as an index of renal function performs fairly well for estimating kidney function in patients with stable chronic kidney disease, it performs poorly in the setting of acute disease. Thus, an ideal biomarker for acute kidney injury would help clinicians and scientists diagnose the most common form of acute kidney injury in hospitalized patients, acute tubular necrosis, early and accurately, and may aid to risk-stratify patients with acute kidney injury by predicting the need for renal replacement therapy, the duration of acute kidney injury, the length of stay and mortality. In this study, renal ischemia and reperfusion were performed by clapming and un-clamping right renal artery in miniature pigs. Plasma blood urea nitrogen (BUN) and creatinine were examined at pre- clamping, after-clamping at 0, 1 and 3 hours. And we searched initial indicators in these samples. Also, renal tissue was collected and searched the initial indicator by PCR and western blotting. As a result, hypoxia inducible factor $1{\alpha}$ ($HIF1{\alpha}$), nuclear factor kappa-B ($NF{\kappa}B$), $I{\kappa}B$, erythropoietin (EPO), erythropoietin receptor (EPOR), angiopoietin-1 and vascular endothelial growth factor (VEGF) were showed significant changes among the renal protein. $HIF1{\alpha}$, EPO, and EPOR were showed significant changes among the renal gene. Thus, these markers will be used as initial diagnosis of acute renal failure.

Neoadjuvant Chemotherapy and Radiation Therapy in Advanced Stage Nasopharyngeal Carcinoma (진행된 병기의 비인강암에서의 선행보조 항암화학요법과 방사선치료)

  • Hong Semie;Wu Hong-Gyun;Park Charn II
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.275-280
    • /
    • 1999
  • Purpose : To assess the feasibility and the toxicity of the neoadjuvant chemotherapy on the treatment of patients with locoregionally advanced nasopharyngeal carcinoma. Methods and Materials : We analyzed 77 previously untreated and histologically confirmed advanced stage nasopharyngeal carcinoma patients treated with neoadjuvant chemotherapy followed by radiation therapy at the Seoul National University Hospital between 1984 and 1996. The stage distribution was as follows : AJCC stage III-2, stage IV-75. Sixty-six patients received infusion of 5-FU (1000 mg/m$^2$, on Day 1$\~$5) and cisplatin (100 mg/m$^2$, on Day 1), eleven patients received infusion of 5-FU (1000 mg/m$^2$, on Day 1 $\~$5) and carboplatin (300 mg/m$^2$, on Day 1) as neoadjuvant chemotherapy Prior to radiation therapy. The median follow-up for surviving patients was 44 months. Results : The overall chemotherapy response rates were 87$\%$. The toxicities of chemotherapy were mild. Only 3 patients experienced Grade 3 toxicities (1 for cytopenia, 2 for nause/vomiting). The degree of radiation induced mucositis was not severe, and ten patients developed Grade 2 mucositis. The 5-year overall survival rates were 68$\%$ and the 5-year disease free survival rates were 65$\%$. The 5-year freedom from distant metastasis rates were 82$\%$ and 5-year locoregional control rates were 75$\%$. Conclusion : This single institution experience suggests that neoadjuvant chemotherapy improves overall survival and disease free survival for patients with advanced stage nasopharyngeal carcinoma without increase of toxicity.

  • PDF

Accuracy of FDG-PET/CT for Detection of Incidental Pre-Malignant and Malignant Colonic Lesions - Correlation with Colonoscopic and Histopathologic Findings

  • Kunawudhi, Anchisa;Wong, Alexandra K;Alkasab, Tarik K;Mahmood, Umar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4143-4147
    • /
    • 2016
  • Purpose: We evaluated all PET/CTs acquired for patients without a primary diagnosis of colorectal cancer, and compared results for those who had subsequent colonoscopy within 6 months, to assess the accuracy of FDG PET/CT for detection of incidental pre-malignant polyps and malignant colon cancers. Materials and Methods: Medical records of 9,545 patients who underwent F-18 FDG PET/CT studies over 3.5 years were retrospectively reviewed. Due to pre-existing diagnosis of colorectal cancer, 818 patients were excluded. Of the remainder, 157 patients had colonoscopy within 6 months (79 males; mean age 61). We divided the colon into 4 regions and compared PET/CT results for each region with colonoscopy and histopathologic findings. True positive lesions included colorectal cancer, villous adenoma, tubulovillous adenoma, tubular adenoma and serrated hyperplastic polyp/hyperplastic polyposis. Results: Of 157 patients, 44 had incidental colonic uptake on PET/CT (28%). Of those, 25 had true positive (TP) uptake, yielding a 48% positive predictive value (PPV); 9% (4/44) were adenocarcinoma. There were 23 false positive (FP) lesions of which 4 were hyperplastic polyp, one was juvenile polyp and 7 were explained by diverticulitis. Fifty eight patients had false negative PET scans but colonoscopy revealed true pre-malignant and malignant pathology, yielding 23% sensitivity. The specificity, negiative predictive value (NPV) and accuracy were 96%, 90% and 87%, respectively. The average SUVmax values of TP, FP and FN lesions were 7.25, 6.11 and 2.76, respectively. There were no significant difference between SUVmax of TP lesions and FP lesions (p>0.95) but significantly higher than in FN lesions (p<0.001). The average size (by histopathology and colonoscopy) of TP lesions was 18.1 mm, statistically different from that of FN lesions which was 5.9 mm (p<0.001). Fifty-one percent of FN lesions were smaller than 5 mm (29/57) and 88% smaller than 10 mm (50/57). Conclusions: The high positive predictive value of incidental focal colonic FDG uptake of 48% for colonic neoplasia suggests that colonoscopy follow-up is warranted with this finding. We observed a low sensitivity of standardly acquired FDG-PET/CT for detecting small polyps, especially those less than 5 mm. Clinician and radiologists should be aware of the high PPV of focal colonic uptake reflecting pre-malignant and malignant lesions, and the need for appropriate follow up.

Practical Considerations of Arterial Spin Labeling MRI for Measuring the Multi-slice Perfusion in the Human Brain (스핀 라벨링 자기공명영상을 이용한 사람 뇌에서의 뇌 관류영상의 현실적 문제점을 향상 시키는 방법 연구)

  • Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • In this work practical considerations of a pulsed arterial spin labeling MRI are presented to reliable multi-slice perfusion measurements In the human brain. Three parameters were considered in this study. First, In order to improve slice profile and Inversion efficiency of a labeling pulse a high power Inversion pulse of adiabatic hyperbolic secant was designed. A $900^{\circ}$ rotation of the flip angle was provided to make a good slice profile and excellent Inversion efficiency. Second, to minimize contributions of a residual magnetization be4ween Interleaved scans of control and labeling we tested three different conditions which were applied 1) only saturation pulses, 2) only spotter gradients, and 3) combinations of saturation pulses and spotter gradients Applications of bo4h saturation pulses and spoiler gradients minimized the residual magnetization. Finally, to find a minimum gap between a tagged plane and an imaging plane we tested signal changes of the subtracted image between control and labeled Images with varying the gap. The optimum gap was about 20mm. In conclusion, In order to obtain high quality of perfusion Images In human brain It Is Important to use optimum parameters. Before routinely using In clinical studios, we recommend to make optimizations of sequence parameters.

  • PDF

Effects of CS682, a Fermentation Product of Korean Soil Bacteria, on Growth Performance in Chickens and Pigs (토착미생물 발효물인 CS682의 급여가 닭과 돼지의 생산성에 미치는 영향)

  • Kim, Hu-Kyung;Kim, Se-Eun;Shim, Kyung-Mi;Kim, Jong-Choon;Bae, Chun-Sik;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.231-236
    • /
    • 2010
  • Antibiotics in veterinary medicine have been used to treat disease, promote growth rate and improve feed efficiency. However, alternative sources are needed because of of bacterial resistance to antibiotics and residues of antibiotics. The present study was carried out to evaluate the effect of CS682, a fermentation product of Korean soil bacteria, on safety, growth rate and feed efficiency, and to evaluate its value as an alternative for antibiotics used as a feed additive. Two dosages of CS682 (0.1% and 1%) were fed to chickens for 28 days. The results showed that, when compared to chickens in the control group, growth and feed efficiency was improved. Also, mortality, hematology, general clinical signs and necropsy were examined. Chickens in the treatment groups showed no adverse effects. A total of 72 weaning pigs were used to confirm the effects of CS682 at one dose level (0.1%) regarding feed efficiency. Supplementation with 0.1% CS682 also resulted in improved weight gain and feed efficiency ratio. Based on these results, CS682 may be effective in improving feed efficiency safely as a feed additive.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.

Usefulness of Magnetic Resonance Imaging after Serial Cranial Ultrasound in the Neonates Graduating Neonatal Intensive Care Unit (신생아 중환자실을 퇴원하는 고위험 환아에서 순차적인 뇌초음파 검사 후 시행한 자기 공명 영상의 유용성)

  • Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.170-177
    • /
    • 2008
  • Purpose : To evaluate usefulness of MR imaging after serial brain US in the high-risk neonates before discharge of the neonatal intensive care unit. Materials and Methods : Retrospective comparison of 412 US and 121 MR scans in 121 neonates and young infants were performed. Grading of germinal matrix/intraventricular hemorrhage (GMH/IVH) was performed and presence of intracranial hemorrhage other than GMH/IVH and parencyma lesions was also analyzed. Results : Among the 242 lateral ventricles, Seven GMH and 46 IVH were additionally detected by MRI. On the other hand, 30 GMH were only detected by US. US demonstrated Grade 1/2/3/4 GMH/IVH in 24/8/13/0 ventricles each, while each grades were identified in 3, 49, 10, 2 ventricles on MR images. Other intracranial lesions additionally detected on MR images were cerebral hemorrhage (n=4), cerebellar hemorrhage (n=4), extraaxial hemorrhage (n=8), diffuse excessive signal change of the white matter (n=72), non-cavitary lesion (n=4), encephalomalacia (n=2), and ventriculomegaly (n=5). Conclusion : MR imaging could be an excellent complimentary study after serial brain US for additional detection of the intracranial pathology, particularly IVH and white matter lesions, though US would be better in follow-up of GMH in some neonates.

  • PDF

Current Status of Imaging Physics & Instrumentation In Nuclear Medicine (핵의학 영상 물리 및 기기의 최신 동향)

  • Kim, Hee-Joung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.83-87
    • /
    • 2008
  • Diagnostic and functional imaging device have been developed independently. The recognition that combining of these two devices can provide better diagnostic outcomes by fusing anatomical and functional images. The representative examples of combining devices would be PET/CT and SPECT/CT. Development and their applications of animal imaging and instrumentation have been very active, as new drug development with advanced imaging device has been increased. The development of advanced imaging device resulted in researching and developing for detector technology and imaging systems. It also contributed to develop a new software, reconstruction algorithm, correction methods for physical factors, image quantitation, computer simulation, kinetic modeling, dosimetry, and correction for motion artifacts. Recently, development of MRI and PET by combining them together was reported. True integration of MRI and PET has been making the progress and their results were reported. The recent status of imaging and instrumentation in nuclear medicine is reported in this paper.