• 제목/요약/키워드: Radiology Department

검색결과 9,189건 처리시간 0.041초

Utilities and Limitations of Cardiac Magnetic Resonance Imaging in Dilated Cardiomyopathy

  • Min Jae Cha;Yoo Jin Hong;Chan Ho Park;Yoon Jin Cha;Tae Hoon Kim;Cherry Kim;Chul Hwan Park
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1200-1220
    • /
    • 2023
  • Dilated cardiomyopathy (DCM) is one of the most common types of non-ischemic cardiomyopathy. DCM is characterized by left ventricle (LV) dilatation and systolic dysfunction without coronary artery disease or abnormal loading conditions. DCM is not a single disease entity and has a complex historical background of revisions and updates to its definition because of its diverse etiology and clinical manifestations. In cases of LV dilatation and dysfunction, conditions with phenotypic overlap should be excluded before establishing a DCM diagnosis. The differential diagnoses of DCM include ischemic cardiomyopathy, valvular heart disease, burned-out hypertrophic cardiomyopathy, arrhythmogenic cardiomyopathy, and non-compaction. Cardiac magnetic resonance (CMR) imaging is helpful for evaluating DCM because it provides precise measurements of cardiac size, function, mass, and tissue characterization. Comprehensive analyses using various sequences, including cine imaging, late gadolinium enhancement imaging, and T1 and T2 mapping, may help establish differential diagnoses, etiological work-up, disease stratification, prognostic determination, and follow-up procedures in patients with DCM phenotypes. This article aimed to review the utilities and limitations of CMR in the diagnosis and assessment of DCM.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

Steatocystoma multiplex: A case report of a rare entity

  • Shin, Nan-Young;Kang, Ju Hee;Kim, Jo-Eun;Symkhampa, Khantaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.317-321
    • /
    • 2019
  • Steatocystoma multiplex is an uncommon benign skin disease, which typically manifests as numerous intradermal cysts that can be scattered anywhere on the body. Although usually asymptomatic, it can be significantly disfiguring. One type of steatocystoma multiplex is known to be associated with the autosomal dominant inheritance of a mutation in the gene coding for keratin 17 (KRT17). In such cases, it is often concurrent with other developmental abnormalities of the ectoderm-derived tissues, such as the nails, hair, and teeth. To the best of our knowledge, few cases have been reported of steatocystoma multiplex of the oral and maxillofacial region. This report describes a case of steatocystoma multiplex of both sides of the neck and multiple dental anomalies, with a focus on its clinical, radiological, and histopathological characteristics, as well as the possibility that the patient exhibited the familial type of this condition.

The influence of X ray beam angulation on the fractal analysis of trabecular architecture in human dry mandible using standardized tile counting method

  • Lee Kyung-Hee;Lee Sun-Bok;An Chang-Hyeon;Heo Min-Suk;Yi Won-Jin;Huh Kyung-Hoe;Park Moo-Soon;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.179-182
    • /
    • 2004
  • Purpose: The purpose of this study is to examine the effects of X-ray beam angulation on the fractal dimension of trabecular bone structure of human dry mandible using the tile counting method. Materials and Methods: We divided 5 human dry mandibles into an angle and a molar groups depending on the regions and deciding the region of interest (ROI). When contrasted with the ROI, the inferior cortex was appointed to be low and the lines perpendicular to the buccal cortex were appointed to be the standard angle. Direct digital intraoral radiographs were obtained from 9 different projection angles. We analyzed statistically the fractal dimension using the tile counting method. Results: There was a statistically significant difference in the fractal dimension of the regions and the mandibles, but there was no statistically significant difference in the fractal dimension according to the X-ray beam angulation. Conclusion : There is no statistically significant effect of the angle of the projection on the fractal dimension of trabecular bone structure of a human dry mandible according to the tile counting method.

  • PDF

Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases

  • Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1066-1076
    • /
    • 2018
  • Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.

Anti-Myelin Oligodendrocyte Glycoprotein Syndrome with Findings Resembling "Snake-Eye Appearance": a Case Report

  • Hong, Sujin;Yi, Jisook;Lee, Ho-joon;Hahn, Seok;Lim, Yun-jung;Lee, Yedaun;Shin, Kyong Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.189-192
    • /
    • 2021
  • Anti-myelin oligodendrocyte glycoprotein (anti-MOG) syndrome is an immune-mediated inflammatory condition of the central nervous system, which usually involves spinal cord and optic nerves. Herein, we studied the case of a 57-year-old female patient who presented with acute/subacute symptoms of sphincter dysfunction, paraparesis, and ocular pain. The patient was diagnosed with anti-MOG syndrome with findings resembling snake-eye appearance (SEA), characterized by nearly symmetrical round high signal intensity lesions located at anterior horns (gray matter) on T2-weighted image.