• Title/Summary/Keyword: Radiological reduction

Search Result 447, Processing Time 0.027 seconds

Verification of Balloon Catheter for Rectal Dose Reduction in Brachytherapy (강내 방사선치료에 있어 직장선량 감소를 위한 풍선형 카테터의 검증)

  • To-Sol, Yu;Young-Min, Moon;Wan, Jeon;Chul-Won, Choi;Bae, Sang-Il;Jin-Young, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.735-740
    • /
    • 2022
  • In order to reduce side effects such as rectal bleeding in the Brachytherapy, the rectal retractor and wet gauze have been used to increase the distance between the rectum and the tandem. However, there were disadvantages that it was difficult to insert through a narrow entrance into the vagina and poor reproducibility. Also, based on the CT image of the selected catheter, the distance from the tandem to the rectum with or without the balloon catheter was checked and the reduction of the dose to the rectum was confirmed. As a result of the experiment, catheter No. 7 was selected considering the maximum balloon size at a level that does not affect the distance between the start point of the balloon and the end of the catheter, and the ovoid applicator. Based on the CT image of the selected catheter, the degree of expansion according to the presence or absence of the balloon catheter was compared, and it was found that the distance difference was 0.3 - 1 cm. In addition, it was confirmed that a decrease of about 32% was observed due to this distance difference. Therefore, the actual clinical application of the selected catheter can be used as a substitute for the existing rectal retractor and wet gauze.

Internal Fixation Using Clavicle Hook Plates for Distal Clavicle Fractures

  • Kim, Kwang-Yul;Kim, Hyung-Chun;Cho, Sung-Jun;Ahn, Su-Han;Kim, Dong-Seon
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • Background: To report the radiological and clinical outcomes of internal fixation using distal clavicle hook plates for distal clavicle fractures. Methods: From April 2008 to December 2012, 32 patients with distal clavicle fractures underwent surgery using an AO hook plate. The reduction was qualified and evaluated according to the radiological findings. The evaluation of the clinical outcomes was performed with the University of California at Los Angeles (UCLA) score, the Korean Shoulder score, and the visual analogue scale (VAS) pain score. Results: By radiological evaluation, we found that 31 of 32 patients showed anatomical reduction and solid bone union. Although we obtained satisfactory UCLA scores, Korean Shoulder Scale scores, and VAS pain scores, 12 cases of complications were present. We found 4 cases of osteolysis of the acromion, 1 case of nonunion, 3 cases of periprosthetic fractures, 3 cases of subacromial pain, and 1 case of skin irritation. We performed re-operations in 2 patients. Conclusions: To avoid complications associated with clavicle hook plates, choosing the appropriate hook size and bending of the hook according to the slope of the acromion undersurface is critical. Also, we believe that early removal of clavicle plates may help reduce complications.

Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography (유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교)

  • An, Se-Jeong;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

The Causes Analysis for the Number of Patients Waiting in General X-ray Room (Focus on Utilization of Quality Improvement (QI)) (일반촬영실의 환자대기건수에 대한 원인별 분석 - QI 활용을 중심으로 -)

  • Dong, Kyung-Rae;Chung, Woon-Kwan;Kim, Chang-Bok;Park, Yong-Soon;Kim, Ho-Sung;Im, In-Chul;Lee, Chang-Lae;Shin, Gyoo-Seul
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.337-346
    • /
    • 2008
  • A questionaire survey was conducted for patients who had been examined at the Department of Radiology to investigate the items that need to be improved. Brainstorming was also conducted by team members to suggest the tactics that can efficiently perform the QI activity by selecting the most frequently answered topics for the reduction of waiting time of x-ray examination. From September 2006 to November 2007, number of patients before and after conducting QI was compared for 3 months by each category differentiated by types of detailed causes. A patient case was set as one shooting for one patient. After conducting QI, the waiting cases before conducting QI were evaluated for the method of improvement for 3 month through the QI team discussion and conducted by following the improvement method for the next 1 month and the waiting cases were measured and the difference before and after the QI activity was compared in percentage. 1. When patient waiting cases were compared before and after conducting QI activity against the causes of repetition, it resulted in 3.9% of reduction effect. 2. When patient waiting cases were compared before and after conducting QI activity against the causes for the lack of guiding, it resulted in 1.1% of reduction effect. 3. When patient waiting cases were compared before and after conducting QI activity against the causes of miss-inputting prescription, it resulted in 1.1% of reduction effect. 4. When patient waiting cases were compared before and after conducting QI activity against the causes for emergency patients, patients with acute pain and discomfort patients, it resulted in 12.0% of reduction effect. 5. When patient waiting cases were compared before and after conducting QI activity against the causes for shooting overlapping of outpatients and hospitalized patients, it resulted in 4.7% of reduction effect. There are many factors to reduce the patient waiting cases in radiography. The first step is for radiology department to find these factors through QI, to improve them, which is the reason why the QI team is organized to perform the QI activities.

  • PDF

Operative Treatment of Tongue Type Intra-articular Calcaneal Fractures: Comparison of the Open Reduction and Essex-Lopresti Technique (관절면을 침범한 설상형 종골골절의 수술적 치료: 관혈적 및 Essex-Lopresti 술식에 따른 비교)

  • Shin, Dong-Eun;Yoon, Hyung-Ku;Han, Soo-Hong;Choi, Woo-Jin;Ahn, Chang-Soo;Ok, Hyun-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.151-156
    • /
    • 2010
  • Purpose: To analyze the clinical and radiological results of operative treatment in patients with tongue type intra-articular calcaneal fracture, and to compare the open reduction and Essex-Lopresti technique. Materials and Methods: We examined a consecutive series of 42 patients who received surgical treatment for tongue type calcaneal fracture (24 cases of the open reduction and 18 cases of the Essex-Lopresti technique) and the postoperative data was compared with a minimum 1 year follow-up. The clinical outcome was analyzed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scale and Salama's criteria. The preoperative, postoperative, and last follow-up changes in the Bohler angle was radiologically analyzed. Results: There were no significant differences between the two groups in terms of the clinical and radiological results at the last follow-up. However, for the Sander's type 3 and 4 fractures, the open reduction group showed more improvement of AOFAS score and less reduction loss in the Bohler angle. Conclusion: Although the clinical results were good irrespective of surgical technique, the open reduction and internal fixation can improve clinical outcome and reduce the reduction loss as compared with the Essex-Lopresti technique in the comminuted tongue type calcaneal fracture.

Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations (노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화)

  • Ha-Seon Jeong;Ie-Jun Kim;Su-Bin Park;Suyeon Park;Yunji Oh;Woo-Seok Lee;Kang-Hyeon Seo;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

Investigation on Evaluation of Exposure Dose & Radiographic Technique for Diagnostic X-ray Examination (X선검진시의 촬영조건과 피폭선량 평가에 대한 조사)

  • Kim Kyung Hwan;Lee Jin Kyu
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.229-251
    • /
    • 2001
  • At the investigations with 200 institutes for analysis of factor associated with radiographic conditions reduction of patient exposure dose during X-ray diagnosis, 170 institutes or $85\%$ answered. For estimation of exposure dose the entrance

  • PDF

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter (X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구)

  • Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.