• 제목/요약/키워드: Radiological contamination

검색결과 105건 처리시간 0.023초

초음파실 표면의 세균 오염평가 (Bacterial Contamination of Surfaces in an Ultrasound Room)

  • 김희정;최유진;이창래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.231-237
    • /
    • 2021
  • The ongoing coronavirus disease 2019 (COVID-19) pandemic has highlighted the importance of hospital hygiene and infection control in hospital settings. To raise hygiene awareness among ultrasound technicians, we evaluated the hygiene status of an ultrasound room, in comparison with that of objects used in daily life. Using the swab method, the following surfaces were examined: eight surfaces in the ultrasound room including the ultrasound probes (convex, linear, sector, 3D), ultrasound track ball, ultrasound keyboard, ultrasound gel (sealed and in use) and pillow as well as four surfaces of everyday objects including subway handles, common computer keyboards, common computer mouse, and cell phones. The streak plate technique was used for inoculation into media, which was observed for the formation of bacterial colonies following incubation for 24 h. Six bacterial strains were detected from objects used in the ultrasound room, including methicillin-resistant Staphylococcus aureus. Four strains of bacteria were detected on surfaces of everyday objects. The equipment and accessories used in an ultrasound room can act as vehicles for infecting patients. Establishment of standardized hygiene protocols and periodic training of the staff are recommended to avoid cross-infection.

영상의학과 촬영실에서의 세균 오염도 측정에 관한 연구 (A study regarding measurements of bacterial contamination levels in radiology room within the department of radiological technology)

  • 동경래;조영국;노상호
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1150-1158
    • /
    • 2009
  • 현재 영상의학과에서 사용되는 촬영장비는 질환을 가지고 있는 환자와의 접촉이 불가피 하기 때문에 병원균이 존재 할 수밖에 없다. 따라서 영상의학과 촬영실에서의 세균 오염도를 측정하고, 검출된 세균들을 소독(물, Tissue Cleaner, 70% 알코올)하여 소독 전 후 세균의 감소율을 비교함으로써 병원감염예방에 있어 소독제 사용의 중요성과 병원감염관리의 인식을 높이고자 한다. 영상의학과 촬영실에서의 세균 오염도를 측정 하였을 때 여러 가지 세균들이 검출되었다. 영상의학과 촬영실내를 소독할 때 물이나 Tissue Cleaner, 환기 보다는 70% Alcohol을 사용하여 소독을 실시하는 것이 세균 사멸 및 병원감염 예방부분에 있어 효과적임을 알 수 있었다. 따라서 세균을 사멸시키기 위해 보다 좋은 소독제를 개발하여야 하며, 병원 내 각종 의료 장비는 언제나 오염될 가능성이 있으므로 기구에 대한 소독 및 멸균을 실시하여 병원감염으로 인해 환자에게 2차 감염을 유발되지 않도록 노력해야 할 것이다.

  • PDF

Visual Sample Plan을 활용한 미신고 시설 핵활동 분석 시료 채취 계획 (Soil sampling plan for Analysis of Nuclear Facility Activities utilizing Visual Sample Plan)

  • 박수희;한지영;박제완;김용민
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.15-21
    • /
    • 2024
  • The Non-Proliferation Treaty (NPT) is the basis of global efforts to prevent the spread of nuclear weapons. In Republic of Korea, safety measures are integrated with NPT approval through agreements with the International Atomic Energy Agency (IAEA) and the Safeguards Agreement. In contrast, Democratic People's Republic of Korea (DPRK), initially an NPT member, withdrew, refusing IAEA nuclear inspections. This inhibits the precise management of DPRK's nuclear facilities and limits access to related information. The Korean Peninsula, politically divided, sees DPRK in control of nuclear weapons. Although the IAEA periodically evaluates DPRK's nuclear facilities, there's a research gap in contamination and site management with nuclear activities. Recognizing the presence or absence of such activities is crucial for peaceful nuclear endeavors. This proposal suggests the number and locations for environmental sample collection using the Visual Sample Plan (VSP) software for nuclear activity analysis. VSP software is sample collection locations and quantities through statistical tests on collected data, ensuring reliability for decision-making. The proposal identifies sites and facilities for nuclear activity analysis based on IAEA safety reports, utilizing the software's embedded methods. Suggested sampling locations for undisclosed nuclear activities employ VSP's embedded techniques, including 'Show that at least some high % of the sampling area is acceptable' to confirm contamination and 'Estimate the Mean' to evaluate the average contamination level.

병원 화장실의 방사성 오염에 관한 연구 (A Study of Radioactive Contamination in Hospital Toilet)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

방사선 사고와 급성 방사선 증후군 (Radiological Accident and Acute Radiation Syndrome)

  • 노형근
    • 대한임상독성학회지
    • /
    • 제9권2호
    • /
    • pp.39-48
    • /
    • 2011
  • In mass casualty situation due to radiological accidents, it is important to start aggressive management with rapid triage decisions. External contamination needs immediate decontamination and internal contamination should be treated with special expertise and equipment to prevent the rapid uptake of radionuclides by target organs. Acute radiation syndrome shows a sequence of events that varies with the severity of the exposure. More severe exposures generally lead to more rapid onset of symptoms and severe clinical findings. After the massive exposure, various systems of the body reflect their severe damages that can lead to death within hours or up to several months. The disease progression has classically been divided into four stages: prodromal, latent, manifest illness, and recovery or death. Three characteristic clusters of symptoms including the hematopoietic syndrome, the gastrointestinal syndrome and the cerebrovascular syndrome are all associated with the acute radiation syndrome. The standard medical management of the patients with a potentially survivable radiation exposure includes good medical, surgical and supportive measures. Specific treatment with cytokines and bone marrow transplantation should be considered. The management of internal contamination is much the same as the treatment of poisoning. The standard decontamination should be applied to reduce uptake, and the chelating agents can be administered to enhance the clearance of radioisotopes. Radioactive iodine ($^{131}I$) as one of the nuclear fission products can increase the incidence of thyroid cancer in children. Potential benefit of potassium iodide prophylaxis is greater especially in neonates, infants and small children.

  • PDF

분말 형태의 황산바륨을 현탁액으로 조제하는 과정에서 발생하는 미생물의 오염도 측정 (Measurement of Microbic Contamination Rate in the Dispensing Process Making Suspension of Barium Sulfate Powder)

  • 김영근;이양섭;조정찬;류명선;이경섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.53-57
    • /
    • 2001
  • The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete, and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus colt were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured, Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensible to manufacturing suspension for preventing from infection.

  • PDF

Film Cassette의 세균 오염도와 소독에 관한 연구 (A Study on Contamination and Disinfection of Film Cassette)

  • 권대철;정경모;최지원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.55-61
    • /
    • 2000
  • In July 2000, a bacteria infection on film cassette contact surface was examined at the diagnostic radiology department of the S. hospital. The objective of this study was to assess the contamination level on film cassette contact surface as a predictor of patient to prevent from nosocomial infection. The study showed that the laboratory result was identified non-pathologic bacterial in the four different cassette size of the contact surface. The study concludes that presence of a bacterial infection wilt prevent a using antiseptic technique on film cassette contact surface. Also the education of nosocomial infection for radiographer will be required.

  • PDF

배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발 (Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes)

  • 김계홍;박찬희;정종헌;이근우;서범경
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.123-128
    • /
    • 2006
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관 내부의 알파/베타선 오염 특성을 직접 평가하기 위해서는 소형의 방사선 검출 시스템이 요구된다. 본 연구에서는 배관 내부의 방사능 오염도를 직접 측정할 수 있는 장비 개발의 일환으로서 기존의 phoswich 검출기와 그 형태가 다른 ZnS(Ag)/플라스틱섬광체 조합의 알파/베타선 동시측정용 phoswich 검출기를 고안하였으며 섬광체 크기 및 검출 시스템의 최적 요건을 실험적으로 확인하고 알파/베타선 신호 분리도를 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 phoswich 검출기의 최적 요건 및 배관 내부의 적용 가능성을 확인하였다.

Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

  • Park, MinSeok;Kim, Han Sung;Yoo, Jaeryong;Kim, Chan Hyeong;Jang, Won Il;Park, Sunhoo
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4122-4129
    • /
    • 2021
  • The counting efficiencies obtained using anthropomorphic physical phantoms are generally used in whole-body counting measurements to determine the level of internal contamination in the body. Geometrical discrepancies between phantoms and measured individuals affect the counting efficiency, and thus, considering individual physical characteristics is crucial to improve the accuracy of activity estimates. In the present study, the counting efficiencies of whole-body counting measurements were calculated considering individual physical characteristics by employing Monte Carlo simulation for calibration. The NaI(Tl)-based stand-up and HPGe-based bed type commercial whole-body counters were used for calculating the counting efficiencies. The counting efficiencies were obtained from 19 computational phantoms representing various shapes and sizes of the measured individuals. The discrepancies in the counting efficiencies obtained using the computational and physical phantoms range from 2% to 33%, and the results indicate that the counting efficiency depends on the size of the measured individual. Taking into account the body size, the equations for estimating the counting efficiencies were derived from the relationship between the counting efficiencies and the body-build index of the subject. These equations can aid in minimizing the size dependency of the counting efficiency and provide more accurate measurements of internal contamination in whole-body counting measurements.