• 제목/요약/키워드: Radiological characteristics

검색결과 666건 처리시간 0.031초

Effect of the Number of Projected Images on the Noise Characteristics in Tomosynthesis Imaging

  • Fukui, Ryohei;Matsuura, Ryutaro;Kida, Katsuhiro;Goto, Sachiko
    • 한국의학물리학회지:의학물리
    • /
    • 제32권2호
    • /
    • pp.50-58
    • /
    • 2021
  • Purpose: In this study, we investigated the relationship between the noise characteristics and the number of projected images in tomosynthesis using a digital phantom. Methods: The digital phantom consisted of a columnar phantom in the center of the image and a spherical phantom with a diameter of 80 pixels. A virtual scan was performed, and 128 projected images (Tomo_w/o) of the phantoms were obtained. The image noise according to the Poisson distribution was added to the projected images (Tomo_×1). Furthermore, another projected image with additional noise was prepared (Tomo_×1/2). For each dataset, we created datasets with 64 (half) and 32 (quarter) projections by removing the even-numbered images twice from the 128 (fully) projected images. Tomosynthesis images were reconstructed by filtered back projection (FBP). The modulation transfer function (MTF) was estimated using the sphere method, and the noise power spectrum (NPS) was estimated using the two-dimensional Fourier transform method. Results: The MTFs did not change between datasets, and the NPSs improved as the number of projected images increased. The noise characteristics of the Tomo_×1_half images were the same as those of the Tomo_×1/2_full. Conclusions: To achieve a reduction in the patient dose in tomosynthesis acquisition, we recommend reducing the number of projected images rather than reducing the dose per projection.

1.5T 자기공명영상을 이용한 물리적 영상 특성에 대한 연구 (Study on the Physical Imaging Characteristics by Using Magnetic Resonance Imaging 1.5T)

  • 민정환;정회원;한지현;이시내;박장호;김기원;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.329-334
    • /
    • 2019
  • This study was purpose to quantitative evaluation of noise power spectrum(NPS) and studied the quantitative evaluation and characteristics of modulation transfer function(MTF) by obtain the optimal edge image by using Coil in magnetic resonance imaging(MRI) equipment through Fujita theory using edge method. The MRI equipment was used (Tim AVANTO 1.5T, Siemense healthcare system, Germany) and the head matrix coil were 12channels(elements) receive coil. The NPS results of showed the best value of 0.004 based on the T2 Nyquist frequency of $1.0mm^{-1}$, and the MTF results of showed that the T1 and T2 values were generally better than the T1 CE and T1 CE FC values. The characteristics of this study were to explain the characteristic method of image quality evaluation in general. To present the quantitative evaluation process and results in the evaluation of MRI image characteristics in radiology.

인천지역 근린공원의 토양 방사능 농도 (Soil Radioactivity in Urban Parks of Incheon)

  • 장준수;이상복;백가은;신희철;이경재;이도화;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.37-42
    • /
    • 2023
  • Most of research on environmental radioactivity is conducted in areas near nuclear power plants, so basic data about the distribution of environmental radioactivity in soil in other areas are insufficient. Therefore, in this study, divide into four categories by the land development characteristics of Incheon and the purpose of development, and confirm the stability of the Incheon through soil sample collection and gamma-ray analysis based on 40K, 137Cs and 226Ra (214Pb, 214Bi). The spectrum obtained by measuring for 80,000 seconds by using the HPGe detector was analyzed by Genie 2000 program. Soil radioactivity concentrations in urban parks of Incheon area are generally within a safe range compared to the results of the Nuclear safety and security commission. However, as 137Cs was detected in one park, which will require continuous monitoring.

흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가 (Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality)

  • 김민경;곽형주;김종훈;최원호;하연경;이소정;김대호;이용구;이영진
    • 전자공학회논문지
    • /
    • 제53권9호
    • /
    • pp.143-147
    • /
    • 2016
  • 최근 디지털 단층영상합성 시스템 (digital tomosynthesis system, DTS)은 일반 X-ray의 영상 중첩현상과 전산화단층촬영장치 (computed tomography, CT)의 높은 선량의 문제점을 해결하기 위하여 개발되었다. 본 연구의 목적은 흉부 촬영용 디지털 단층영상합성 시스템 (chest digital tomosynthesis, CDT)의 재구성 알고리즘 개발 및 화질과 선량 평가를 수행하는 것이다. 영상의 재구성은 필터 후 역투영 (filtered back-projection, FBP)을 모델링하였고, 팬텀 영상을 획득하기 위한 X-선과 검출기 사이의 각도를 ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, 그리고 ${\pm}30^{\circ}$로 구성하였다. 영상의 화질 평가는 평균 제곱근 편차 (root mean square error, RMSE)와 신호대 잡음 변화율 (signal difference-to-noise ratio, SDNR)로 수행하였고, 선량 평가는 ${\pm}20^{\circ}$의 범위에서 유효선량으로 수행하였다. 결과적으로, 모든 각도에서 Slice thickness 필터를 적용한 팬텀영상이 가장 우수한 RMSE와 SDNR 결과를 나타내었고, 최종 유효 선량은 0.166 mSv로 측정되었다. 결론적으로, 개발한 CDT 재구성 알고리즘의 유용성을 증명하였고, 최종 유효 선량을 측정하여 CDT의 기초 실험 데이터를 구축할 수 있었다.

모니터 전리함 시작품 개발과 기초 성능 평가 (Development of Monitor Chamber Prototype and Basic Performance Testing)

  • 이무진;임희진;이만우;이준규;이동주;강상구;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 2015
  • 모니터 전리함은 의료용 선형가속기에서 방출되는 방사선의 세기와 출력 제어를 위하여 사용된다. 본 연구에서는 가속기 기반 방사선 발생장치의 제어 시스템 개발에 사용하기 위하여 모니터 전리함 시작품을 개발하였다. 개발한 모니터 전리함은 평행 평판형 전리함 형태로서 독립적 작동이 가능한 두 개의 전리함으로 구성되어 있으며, 전극의 재료는 방사선의 감쇠를 최소화하기 위하여 얇은 연성인쇄회로기판이 사용되었다. 전리함의 시험을 위하여 코발트-60 방사선원을 이용하여 측정된 전하의 포화특성과 선형성과 같은 선량학적 특성을 평가하였다. 결과적으로 개발된 시작품이 기본 성능을 만족하며 추가 연구의 가능성을 확인하였다.

유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가 (Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors)

  • 목성윤;강영록;김효진;계용욱;안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도 (Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist)

  • 김은혜;임청환;임우택;주영철;홍동희;정홍량;문영주;김훈;정영진;최지원;윤용수;조평곤;박명환;양오남;정봉재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.

의료기사의 직무스트레스와 만족도의 영향요인 비교 : 인천지역을 중심으로 (Comparison of Factors Affecting Job Stress and Satisfaction of Medical Technician : Focus on Incheon Area)

  • 이은모;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.627-635
    • /
    • 2018
  • The purpose of this study was to compare the job stress, job satisfaction, turnover intention, and job performance feelings of radiological technologists, physical therapists, and medical laboratory technologists working at university hospitals and general hospitals. The subjects were 114 general practitioners and 217 university hospital workers who are engaged in occupations of radiological technologists, physical therapists, and medical laboratory technologists in the age groups 20-50 years living in Incheon Metropolitan City. Data collection was conducted from April 1, 2017 to April 30, and data analysis was performed using the SPSS/WIN 23 statistical program. There were statistically significant difference in the job stress of medical technician by age, marriage, occupation, hospital size, position, parenting form, employment type, and lunch break. Job stress by occupation was highest in medical laboratory technologists, followed by radiological technologists and physical therapists. Job satisfaction was the highest among physical therapists. followed by radiological technologists and medical laboratory technologists. There were significant differences in age, occupation, parenting form, type of employment, and lunch break according to demographic characteristics. In order to reduce the job stress and job satisfaction of the medical technician working at the hospital, the development of the job environment should be sought and the hospital should also be removed from the authoritarian management system.

의원방사선사의 병원감염 인지도 및 수행도에 관한 연구 (A Study on Awareness and Performance of Infection Control of Local Clinic Radiological Technologist)

  • 정봉재;김현진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.739-747
    • /
    • 2019
  • 본 연구는 경남지역 의원에 근무하는 방사선사를 대상으로 감염관리에 대한 연구로 감염관리에 대한 인지도와 수행도를 분석하여, 지역의원에 근무하는 방사선사의 감염관리 교육을 위한 기초자료를 제공하고자 시행하였다. 연구에 사용한 도구는 설문지로 2018년 04월01일부터 08월31일까지 경남에 소재하는 의원에 근무하는 방사선사를 대상으로 설문지 총150부를 배부하여 연구에 적합한 131부를 SPSS 18.0 통계 프로그램을 이용하여 분석하였다. 감염관리에 대한 요인으로는 감염관리에 대한 특성 12문항과 감염관리에 대한 인지도 및 수행도로 총60문항으로 분석하였다. 연구대상자의 일반적 특성을 기준으로 기술통계, t-test, ANOVA, 상관관계 및 회귀분석을 하였다. 감염관리에 대한 인지요인에 대한 총인지도는 $4.13{\pm}.05$점으로 높게 나타났으며, 수행요인에 대한 총수행도는 $4.05{\pm}.05$점으로 높게 나타나 감염관리에 대한 인지도 및 수행도에서 경남지역 의원에 근무하는 방사선사들의 감염관리 수준은 수행도가 인지도에 비해 조금 낮게 나타났지만, 비교적 높은 것으로 분석되었다. 지역의원 방사선사의 감염관리는 병원을 운영하는 의료진의 지속적인 감염교육 활동과 예방활동을 통해 의원에 근무하는 방사선사 역시 감염관리의 전문가로 자리 매김하여야 할 것이다.