• Title/Summary/Keyword: Radiological Assessment

Search Result 475, Processing Time 0.024 seconds

Hepatic Cirrhosis Secondary to chronic Hepatitis in an English Cocker Spaniel (ECS) Dog (잉글리쉬 코커스파니엘 견에서 발생한 만성 간염 및 간경화 증례)

  • Park Chul;Yoo Jong-Hyun;Jung Dong-In;Kim Ha-Jung;Kang Byeong-Teck;Lim Chae-Young;Yoon Hun-Young;Jeong Soon-Wuk;Sur Jung-Hyang;Park Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.72-76
    • /
    • 2006
  • A 1-year-old, female English cocker spaniel (ECS) dog was presented with 3-month history of vomiting and retaking of the vomitus, and chronic weight loss. The client had noticed mild abdominal distension 10 days before. The dog was diagnosed as chronic hepatitis with hepatic cirrhosis based on complete blood count (CBC), serum chemistry profiles, radiography, ascites assessment, bile acid evaluation, and liver biopsy through exploratory laparotomy and necropsy. CBC and serum chemistry profiles revealed mild anemia, slightly elevated hepatic enzymes (ALT and AST), increased creatinine kinase (CK), hyperammonemia, and hypoproteinemia with hypoalbuminemia. Ascites was transudate according to analysis of components. Bile acid assessment (fasting; $174.4{\mu}mol/L$ and postprandial; $198.4{\mu}mol/L$) showed strongly suspected hepatic insufficiency. On radiological findings, ascites was evident. Atrophied liver (especially left side lobes) and distended mesenteric vasculatures were observed by exploratory laparotomy. Histopathological examination of marginal lesion of left lateral lobe of liver by biopsy revealed the necrosis of hepatic cells, dilation of sinusoids, infiltration of neutrophils in sinusoids, and vacuolation of hepatic cytoplasm. The patient had been managed with careful low protein diet and specific supportive therapy (ursodeoxycholic acid, prednisolone, vitamine E, and interferon). Vomiting and ascites disappeared with medical management. The dog was monitored periodically by CBC, serum chemistry and radiographic examination. The dog survived more 18 months with medical therapy. After spontaneous death, necropsy and histopathologic examination were performed.

Relationship between Parental Career Support, Career Self-Regulation, and Career Identity - with Student Dep. of Radiologic Technology - (부모진로지지와 진로자기조절, 진로정체감의 관계 - 방사선과 학생 대상 -)

  • Kim, In-Sook;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.295-304
    • /
    • 2015
  • This study intended to examine the correlation of career self-regulation (plan and check-up, positive thinking, career feedback, environment formation for career) and career identity (career decision, indecisiveness, career indecision) caused by parental career support (informative, emotional, financial, and empirical) among freshmen, sophomores, and juniors in the radiotechnology department. For assessment, a survey was conducted and according to the results, there existed correlation as follows. Regarding parental career support, emotional support is plan and check-up (r=.25, p<.001), Career feedback (r=.54, p<.001), and positive thinking (r=.46, p<.001) showed high positive correlation while informative support showed correlation in all factors showing high correlation with environment formation for career (r=.22, p<.001), plan and check-up (r=.20, p<.001), career feedback (r=.24, p<.001), and positive thinking (r=.26, p<.001). Financial support career feedback (r=.33, p<.001) and positive thinking (r=.34, p<.001) showed somewhat higher correlation. All factors of environment formation for career (r=.18, p<.001), plan and check-up (r=.25, p<.001), career feedback (r=.37, p<.001), and positive thinking (r=.30, p<.001) showed high correlation. Informative support showed high correlation only with career decision (r=.27, p<.001) and financial support also showed high correlation only with career decision (r=.18, p<.001). Also, empirical support was somewhat highly correlated only with career decision (r=.23, p<.001). Regarding school-year difference depending on parental career support, there was significant difference between emotional support (F=8.52, p<.001), financial support (F=8.97, p<.001), and empirical support (F=5.36, p<.05) while informative support was dismissed. Regarding school-year difference depending on career self-regulation, there was significant difference between career feedback (F=8.48, p<.001) and positive thinking (F=16.29, p<.001) while environment formation for career and plan and check-up were dismissed. Regarding school-year difference depending on career identity, there was significant difference between career indecision (F=4.01, p<.05) and career decision (F=11.72, p<.001) while indecisiveness was dismissed. According to the analysis results, parents' active support to their child like respecting and listening to their opinion on career, provision of career related experience or information, and provision of necessary financial aid for their study or academic preparation made the students plan and exploring their career, examine accomplishment progress, have positive idea to realize their objectives. In addition, the students were able to establish the objective of their career by forming the environment that helped them realize their objectives by seeking advices and encouragement from surroundings. Meanwhile, the parents' attitude to respect and listen to their child's career related opinion affected their career decision and indecision. Although informative support helped the students' career decision, financial and empirical support caused effect only to career decision.

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

A Study on the Overall Economic Risks of a Hypothetical Severe Accident in Nuclear Power Plant Using the Delphi Method (델파이 기법을 이용한 원전사고의 종합적인 경제적 리스크 평가)

  • Jang, Han-Ki;Kim, Joo-Yeon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Potential economic impact of a hypothetical severe accident at a nuclear power plant(Uljin units 3/4) was estimated by applying the Delphi method, which is based on the expert judgements and opinions, in the process of quantifying uncertain factors. For the purpose of this study, it is assumed that the radioactive plume directs the inland direction. Since the economic risk can be divided into direct costs and indirect effects and more uncertainties are involved in the latter, the direct costs were estimated first and the indirect effects were then estimated by applying a weighting factor to the direct cost. The Delphi method however subjects to risk of distortion or discrimination of variables because of the human behavior pattern. A mathematical approach based on the Bayesian inferences was employed for data processing to improve the Delphi results. For this task, a model for data processing was developed. One-dimensional Monte Carlo Analysis was applied to get a distribution of values of the weighting factor. The mean and median values of the weighting factor for the indirect effects appeared to be 2.59 and 2.08, respectively. These values are higher than the value suggested by OECD/NEA, 1.25. Some factors such as small territory and public attitude sensitive to radiation could affect the judgement of panel. Then the parameters of the model for estimating the direct costs were classified as U- and V-types, and two-dimensional Monte Carlo analysis was applied to quantify the overall economic risk. The resulting median of the overall economic risk was about 3.9% of the gross domestic products(GDP) of Korea in 2006. When the cost of electricity loss, the highest direct cost, was not taken into account, the overall economic risk was reduced to 2.2% of GDP. This assessment can be used as a reference for justifying the radiological emergency planning and preparedness.

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

The Effects of Near Miss and Accident Prevention Activities and the Culture of Patient Safety Management for the Patient Safety (Near Miss 사고 예방 활동과 환자안전관리 문화형성이 환자안전에 미치는 영향)

  • Chang, Ho-Suk;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.138-144
    • /
    • 2010
  • Purpose: Despite the rapidly changing healthcare environment, healthcare organizations have recognized the importance of patient safety management. But patient safety management has the problem of the lack of participation of members due to the process of focusing on the follow-up service and punishment. The department of nuclear medicine in Uijeongbu St. Mary's Hospital started this research to reduce the near miss and prevent patient safety accidents by both initiating the participatory near-miss-proof activities as an advance management and constructing a system without disadvantages of reporting. In addition, this research aims to establish a differentiated patient safety management system in the department of nuclear medicine. Materials and Methods: 1. Colleting cases of team members' past and present near miss and accidents(First data collection). 2. Quantifying the cases of near miss and accidents after identifying the degree of importance and urgency through surveys(Second data collection). 3. Quantifying cases and indentifying important points of contact through data analysis. 4. Making and standardizing a manual for important points of contact, and initiating participatory activities to prevent errors. 5. Activating web-based community for establishing the report system of near miss. 6. Estimating the result of before and after activities through surveys and focus group interviews. Results: 1) Quantified safety accidents and near miss in the department of nuclear medicine. About 50 near misses a month and one safety accident a year. 2) Establishing improvement measurements based on quantified data. About 11 participatory activities, the improvement of process, a manual for standardization. 3) Creating a system of safety culture and high participation rate of team members. Constructing a report system, making a check list and a slogan for safety culture, and establishing assessment index. 4) Activating communities for sharing the information of cases of near misses and accidents. 5) As the result of activities, the rate of near miss occurrence declined by 50% and the safety accident did not happen. Conclusion: The best service in the department of nuclear medicine is to provide patients with safety-guaranteed high-quality examination and cure. This research started from the question, 'what is the most faithful-to-the-basics way to provide the best service for patients?' and team members' common answer for this question was building a system with participation of all members. Building a system through the participatory improvement activities for preventing near miss and creating safety culture resulted in the 50% decline of near miss occurrence and no accident. This is a meaningful result from the perspective of advance management for patient safety. Moreover, this research paved the way for creating a culture to report and admit near miss or accidents by establishing a report system with no disadvantage of reporting. The system which sticks to the basics is the best service for patients and will form a patient safety culture system, which will lead to the customer satisfaction. Therefore, all members of the department of nuclear medicine will develop a differentiated patient safety culture with stabilizing the established system.

  • PDF

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Nuclear Terrorism and Global Initiative to Combat Nuclear Terrorism(GICNT): Threats, Responses and Implications for Korea (핵테러리즘과 세계핵테러방지구상(GICNT): 위협, 대응 및 한국에 대한 함의)

  • Yoon, Tae-Young
    • Korean Security Journal
    • /
    • no.26
    • /
    • pp.29-58
    • /
    • 2011
  • Since 11 September 2001, warnings of risk in the nexus of terrorism and nuclear weapons and materials which poses one of the gravest threats to the international community have continued. The purpose of this study is to analyze the aim, principles, characteristics, activities, impediments to progress and developmental recommendation of the Global Initiative to Combat Nuclear Terrorism(GICNT). In addition, it suggests implications of the GICNT for the ROK policy. International community will need a comprehensive strategy with four key elements to accomplish the GICNT: (1) securing and reducing nuclear stockpiles around the world, (2) countering terrorist nuclear plots, (3) preventing and deterring state transfers of nuclear weapons or materials to terrorists, (4) interdicting nuclear smuggling. Moreover, other steps should be taken to build the needed sense of urgency, including: (1) analysis and assessment through joint threat briefing for real nuclear threat possibility, (2) nuclear terrorism exercises, (3) fast-paced nuclear security reviews, (4) realistic testing of nuclear security performance to defeat insider or outsider threats, (5) preparing shared database of threats and incidents. As for the ROK, main concerns are transfer of North Korea's nuclear weapons, materials and technology to international terror groups and attacks on nuclear facilities and uses of nuclear devices. As the 5th nuclear country, the ROK has strengthened systems of physical protection and nuclear counterterrorism based on the international conventions. In order to comprehensive and effective prevention of nuclear terrorism, the ROK has to strengthen nuclear detection instruments and mobile radiation monitoring system in airports, ports, road networks, and national critical infrastructures. Furthermore, it has to draw up effective crisis management manual and prepare nuclear counterterrorism exercises and operational postures. The fundamental key to the prevention, detection and response to nuclear terrorism which leads to catastrophic impacts is to establish not only domestic law, institution and systems, but also strengthen international cooperation.

  • PDF

Technical Standards and Safety Review of the Low and Intermediate Level Radioactive Waste Disposal Facility (중.저준위 방사성폐기물 처분시설에 대한 기술기준 및 안전심사)

  • Cheong, Jae-Hak;Lee, Kwan-Hee;Lee, Yun-Keun;Jeong, Chan-Woo;Rho, Byung-Hwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.357-368
    • /
    • 2008
  • On July 31, 2008, the Government issued the construction and operation permit for the first low and intermediate level radioactive waste disposal facility in the Republic of Korea. In this paper, the fundamental regulatory framework, regulatory requirements and technical standards of the disposal facility are introduced, and the phased review process adopted for evaluation of the safety of the facility is briefly described. The Atomic Energy Act sets forth a stepwise regulatory framework for the whole life-cycle of the disposal facility such as siting, design, construction, operation, closure and institutional control. More detailed regulatory requirements and technical standards are stipulated in the subsequent regulations of the Atomic Energy Act and a series of Notices issued by the Ministry of Eduction, Science and Technology. The Korea Institute of Nuclear Safety, as entrusted by the Ministry under the Atomic Energy Act, conducted safety review on the disposal facility, and evaluated the compliance with relevant criteria in all technical elements(i.e. siting and structural safety, radiological environmental impact, operational safety, systems and components, quality assurance, and total systematic performance assessment, etc.). The overall safety review process can be phased into inception phase, initial review phase, main review phase and completion phase. The review results were reported to and deliberated by the five Sub-committees of the Special Committee on Nuclear Safety, and then reported to the Ministry. The Ministry issued the construction and operation permit of the disposal facility through the deliberation of the review results by the Nuclear Safety Commission. Hereafter, the safety of the repository will be reassured by a series of subsequent regulatory inspections and reviews under the Atomic Energy Act. In addition, the licensee's continuous implementation of the "Safety Promotion Plan" may also enhance the long-term safety of the repository and contribute to build-up the confidence of the safety case.

  • PDF

Assessment of Inhalation Dose Sensitivity by Physicochemical Properties of Airborne Particulates Containing Naturally Occurring Radioactive Materials (천연방사성물질을 함유한 공기 중 부유입자 흡입 시 입자의 물리화학적 특성에 따른 호흡방사선량 민감도 평가)

  • Kim, Si Young;Choi, Cheol Kyu;Park, Il;Kim, Yong Geon;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.216-222
    • /
    • 2015
  • Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of $0.01{\mu}m$ sized particulates were higher than doses due to $100{\mu}m$ sized particulates by factors of about 100 and 50 for $^{238}U$ and $^{230}Th$, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of $11g{\cdot}cm^{-3}$ and $0.7g{\cdot}cm^{-3}$ resulted in dose difference by about 60 %. For $^{238}U$, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of $^{238}U$ was about 9 times higher than dose for absorption F. For $^{230}Th$, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of $^{230}Th$ was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and conditions and use the site specific particulate properties to accurately access radiation dose to workers at NORM processing facilities.