• Title/Summary/Keyword: Radiologic Technologists

Search Result 78, Processing Time 0.02 seconds

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008- (진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008-)

  • Kang, Hee-Doo;Dong, Kyung-Rae;Kweon, Dae-Cheol;Choi, Jun-Gu;Jeong, Jae-Ho;Jung, Jae-Eun;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

Investigation of the Time Required for General Radiography (일반 방사선검사의 소요 시간 실태조사)

  • Lim, Woo-Taek;Joo, Young-Cheol;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.255-262
    • /
    • 2022
  • In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.

The Associated Factors of Protective Behaviors for Radiation Exposure based on Health Belief Model Honam Province Radiologic Technologists (건강신념모델을 적용한 호남지역 방사선사의 방사선 방어행위 수행도 관련 요인)

  • Yoon, Yo-Sang;Ryu, So-Yeon;Park, Jong;Choi, Seong-Woo;Oh, Hye-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.96-107
    • /
    • 2020
  • This study aimed to identify the associated factors of protective behaviors for radiation exposure among some radiology technologists using the Health Belief Model. The subjects of the study were 541 radiology technologists working at hospitals or clinics in Honam Province. Using the SPSS version 18.0 program, data were analyzed using a t-test, ANOVA, Pearson's correlation analysis, and hierarchical multiple logistic regression analysis. To modify the factors, the performance of subjects who had a higher level of education and nuclear medicine rooms were higher than those who worked in simple radiography rooms. The radiation protective behaviors performance of the subjects who had more exercise, medium-level stress, and worked in higher-quality protection facilities was higher. Regarding the personal perceptions, the cues to action (β=.292, p=.0001), and perceived seriousness (β =.075, p=.010) were factors that had effects on the performance of radiation protection behaviors. Regarding the likelihood of action, the benefits (β=.168, p<.0001), self-efficacy (β=.148, p=.007), and the performance of protective behaviors were higher. In conclusion, protection education as a cue to action should be provided to stimulate protective behaviors, and the benefits of protective behaviors should be emphasized. To increase the performance of protection behaviors, self-efficacy should be enhanced, and the subjects are offered appropriate information that helps perceive seriousness.

Analysis of the Necessity of Medical Records Related to Radiological Examination (방사선검사의 의무기록에 관한 요구도 분석)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won;Jeong, Sung-Hun;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.

A Comparison of the Korean and Japanese Medical Technician's. Etc. Act Systems Focusing on Physical and Occupational Therapists

  • Yoon, Tae-Hyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.128-135
    • /
    • 2016
  • Purpose: The aim of this study was to compare the "Physical Therapist and Occupational Therapist Act" of Japan and the "Medical Technician's. Etc. Act" of Korea in order to establish the grounds for improvement of effective law-making. Methods: We obtained the "Medical Technician's. Etc. Act" from the Korean Ministry of Government Legislation and the "Physical Therapist and Occupational Therapist Act" from the Japanese Ministry of Health, Labor and Welfare. It was translated from an association by related Japanese and experts. Results: The laws consisted of acts, enforcement ordinances, and enforcement regulations in both Korea and Japan. In the Korean case, eight occupations were defined in one law including six types of medical technicians, as well as medical recorders and opticians. The "Physical Therapist and Occupational Therapist Act" in Japan is composed of 6 chapters and 22 articles, while the Korean Act consists of 33 articles without chapters. Among them, 11 articles covered the establishment and management of dental laboratories and eyeglass shops, and only 22 articles were related to physical therapists and occupational therapists. Conclusion: Independent laws should be established for each type of medical technician. They must be comparable to Japanese laws on physical therapists and occupational therapists as well as clinical pathologists, dental hygienists, dental technicians, radiologic technologists, medical recorders, and opticians.

Image Quality Management Using ALVIM Phantom (ALVIM Phantom을 이용한 화질관리)

  • Im, Deuk-Chun;Dong, Kyung-Rae;Park, Yong-Soon;Kim, Chang-Bok;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.63-68
    • /
    • 2009
  • Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers' ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

  • PDF

A Study on the Scattered Dose in Portable Chest Radiography (portable 흉부촬영시 공간산란선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Hwan-Hyung
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.