• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.023 seconds

Clinical and Radiological Characteristics in Patients with Postoperative Maxillary Cyst: A Retrospective Study

  • Hyoung-Cheol Kim;Suk-Ja Yoon;Yeong-Gwan Im;Jae-Seo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.3
    • /
    • pp.81-86
    • /
    • 2023
  • Purpose: To evaluate the clinical and radiologic findings of the postoperative maxillary cysts (POMCs) and investigate the relationship between lesion size and clinical symptoms depending on the time elapsed after radical maxillary sinus surgery. Methods: A total of 29 patients who were diagnosed with POMCs at Chonnam National University Dental Hospital were selected. Clinical and radiologic findings were investigated. POMC cases were divided into two groups: those with <24 years between maxillary sinus surgery and POMC diagnosis and those with >24 years. The chi-square test was used to compare the differences between the two groups. Results: The average period from surgery to POMC detection was 24.32 years; however, the period could not be confirmed in four patients. The average patient age was 52.75 years, and 12 (41.3%) patients were in their 50s. POMC-related clinical symptoms were as follows: buccal pain and swelling, dull pain, toothache, abscess, sensory abnormality, and asymptomatic. Twenty (69.0%) cases showed unilocular radiolucency and 9 (31.0%) revealed multilocular radiolucency. Seven cases (35.0%) were misdiagnosed as odontogenic lesions, resulting in the delayed treatment of POMCs. No statistical significance was found between the two groups with respect to symptoms, expansion to the surrounding area, presence of secondary cysts, and mesiodistal length of cyst on cone-beam computed tomography (CBCT) images. However, the buccopalatal length of the cyst on CBCT images was significantly different between the two groups. Conclusions: The buccopalatal length of POMCs observed on CBCT images was related to the time elapsed since surgery. The lack of awareness of POMCs may lead to misdiagnosis as an odontogenic infection and delayed treatment. Therefore, dentists must recognize the clinical and radiologic features of POMCs to differentiate it from dental infections.

Report for Spreading Culture of Medical Radiation Safety in Korea : Mainly the Activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) (국내 의료 방사선 안전문화 활동 현황 : 의료방사선안전문화연합회 중심으로)

  • Yoon, Yong-Su;Kim, Jung-Min;Kim, Hyun-Ji;Choi, In-Seok;Sung, Dong-Wook;Do, Kyung-Hyun;Jung, Seung-Eun;Kim, Hyung-Soo
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • There are many concerns about radiation exposure in Korea after Fukushima Nuclear Plant Accident on 2011 in Japan. As some isotope materials are detected in Korea, people get worried about the radioactive material. In addition, the mass media create an air of anxiety that jump on the people's fear instead of scientific approach. Therefore, for curbing this flow, health, medical institute from the world provide a variety of information about medical radiation safety and hold the campaign which can give people the image that medical radiation is safe. At this, the Korean Food and Drug Administration(KFDA) suggested that make the alliance of medical radiation safety and culture on August, 2011. Seven societies and institutions related medical radiation started to research and advertise the culture of medical radiation safety in Korea. In this report, mainly introduce the activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) for spreading culture of medical radiation safety from 2011 to 2012.

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

Measurement of the Scattered Spatial Dose Distribution for the Mobile X-ray Radiography (이동형 X선촬영에서 공간산란선량 분포 측정)

  • Kwon, Deok-Mun;Park, Myeong-Hwan;Nam, Hyo-Duk
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.23-26
    • /
    • 2001
  • The spatial distribution of the scattered dose for mobile X-ray radiography is measured. The scattered X-ray exposures at the radius of 50, 100 and 150 cm from the irradiation center are 880, 180 and $50\;{\mu}R$, respectively. This scattered X-rays can be reduced to 60% by inserting the portable shield made by 0.4 mm copper sheet sandwiched in two plywoods.

  • PDF

Determination of Dose Distribution under Nonequivalent Condition by Prosthesis in Radiotherapy (방사선 치료시 인공고관절 삽입에 의한 불균질면에서의 선량분포 평가)

  • Lee, Joon-Il;Kim, Sung-Hwan
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.43-46
    • /
    • 1998
  • When a patient was irradiated with prosthetic hip, the dose distribution was changed according to inhomogeneous materials. The density, effective atomic number, and the composition of material had influence on absorbed dose distribution. In this study, the influence of inhomogeneous material(Ti) was measured using a polyethylene phantom, which consisted of various diameter of titanium, with film dosimetry. As a result, the backward dose showed 29.5% increas by backscattering, the forward dose showed 28% decreas by absorption, and the side dose showed 7% increas by scattering, when 25 mm diameter Ti was used. In addition forward dose was in inverse proportion to the thickness of prosthetic material. When the prosthetic hip of patient is in an irradiated field, we must carefully study the absorbed dose distribution.

  • PDF

A Study of 2-dimensional X-ray Detector using Monte Carlo Simulation (몬테 카를로 시뮬레이션을 이용한 2차원 X-선 검출기에 대한 연구)

  • Shin, Hyoung-Sup;Lee, Hak-Jae;Lee, Ki-Sung;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.67-70
    • /
    • 2010
  • X-ray absorption rate and multiplication factor of X-ray detector were calculated with Garfield code. High Z (= atomic number) was important factor to increase the absorption rate but low Z is also important to increase the multiplication. Five different gas composition were examined under the condition of 1400 V bias and 400 um gap. Xe 100% gas showed the highest absorption rate and He 96% + isobutene 4% showed the highest multiplication.

MATERIAL INVESTIGATION AND ANALYSIS USING CHARACTERISTIC X-RAY

  • Oh, Gyu-Bum;Lee, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.426-433
    • /
    • 2010
  • The characteristic X-rays emitted from materials after gamma ray exposure was simulated and measured. A CdTe semiconductor detector and a $^{57}Co$ radiation source were used for energy spectroscopy. The types of materials could be identified by comparing the measured energy spectrum with the theoretical X-ray transition energy of the material. The sample composition was represented by the $K_{\alpha1}$-line (Siegbahn notations), which has the highest intensity among the characteristic X-rays of each atom. The difference between the theoretic prediction and the experimental result of K-line measurement was < 0.61% even if the characteristic X-rays from several materials were measured simultaneously. 2D images of the mixed materials were acquired with very high selectivity.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Clinicoradiologic Differential Diagnosis of Odontogenic Keratocyst and Ameloblastoma (치성각화낭과 법랑모세포종의 임상 및 방사선학적 감별진단)

  • Jeong Ho-Gul;Lee Jang-Yeol;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.249-254
    • /
    • 2000
  • Purpose: To clarify the clinical and radiologic parameters that can be used to differentiate odontogenic keratocyst and ameloblastoma Materials and Methods: The records of 46 patients of ameloblastoma and 48 patients of odontogenic keratocyst at the Yonsei University Dental Hospital during the period of 1979 to 1995 were retrospectively reviewed. As a possible means for differentiating between the odontogenic keratocyst and ameloblastoma, the clinical parameters and the radiologic parameters were evaluated. Results: In the clinical parameters, there was no significant difference in age, sex, and sign and symptoms (p>0.05). In the radiologic parameters, there was significant difference in site, shape of the lesion, and external root resorption of adjacent teeth (p<0.05). Conclusion: The site, shape of the lesion, and external root resorption of adjacent teeth can be the parameters to differentiate odontogenic keratocyst and ameloblastoma, but a definite differentiation of these two lesions needs a more specialized imaging modality.

  • PDF

Ultrastructure of Pseudogobio esocinus (Teleostei, Cyprinidae) Spermiogenesis and Spermatozoa (모래무지(Teleostei, Cyprinidae) 정자변형과정과 정자의 미세구조)

  • Kim, Kgu-Hwan;Kwon, Deok-Mun;Lee, Jun-Ill;Jung, Sung-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.3
    • /
    • pp.147-152
    • /
    • 2007
  • Spermiogenesis and mature spermatozoa of the Korean false minnow Pseudogobio esocinus (Cyprinidae) are described by means of scanning and transmission electron microscopy. Spermiogenesis is characterized by lateral development of the flagellum, absence of nuclear rotation, and eccentric nuclear fossa formation. The spermatozoa have a spherical head containing a nucleus with highly condensed chromatin and no acrosome. The nuclear fossa contains the proximal centriole and anterior part of the distal centriole. The midpiece is type A II and contains semi-fused mitochondria around the axoneme. However, the symmetrical distribution of 4 or more the mitochondria does not follow a general pattern of the cyprinid spermatozoa. Cytoplasmic vesicles in the midpiece are common in Cypriniformes and some of Siluriformes and Characiformes spermatozoa.