• Title/Summary/Keyword: Radiologic Science

Search Result 480, Processing Time 0.023 seconds

Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study (SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구)

  • Kim, Jee Eun;Kim, Ye Seul;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.405-414
    • /
    • 2021
  • Purpose. This study was conducted to evaluate clinical usefulness by evaluating the marginal bone resorption and survival rate of an implant with a taper straight type SLA surface domestically available on the market recently. Materials and methods. 40 implants satisfying the including criteria were observed for one year of 125 implants of 83 adult men and women who had KISPLANT® implanted from August 2016 to December 2019 at the Department of Periodontology, Chonnam National University Dental Hospital. The marginal bone level was measured on periapical radiographs taken initially and 1 year later and we analyzed implant survival and success rates. A t-test was used for the analysis of the association between the marginal bone resorption and the severity of periodontitis, supportive periodontal therapy, the inserted site, the cause of extraction, immediate placement, and systemic disease. Results. After 1 year of loading, the mesial bone resorption was 0.74 ± 1.07 mm, and the distal bone resorption was 0.53 ± 1.04 mm. The marginal bone resorption of 2 mm or more occurred at 3 implants out of 40 implants after 1 year, so the success rate of implant was 92.5% and survival rate was 100%. There was a significant difference in mesial marginal bone resorption according to the inserted site and no significant differences were found between marginal bone resorption and the other factors. Conclusion. As a result of marginal bone resorption, success rate, and survival rate in this study, we found little marginal bone resorption and high survival and success rate. It can be concluded that they represent excellent clinical results.

Analysis of Health Insurance Standards and Utilization of MRI in Korea: Based on Health Insurance Claim Data (한국의 MRI 건강보험 급여기준 및 진료이용에 관한 연구)

  • Cho, Young-Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.869-877
    • /
    • 2018
  • This study analyzed the current status of MRI (frequency, amount of treatment) based on the history of application of the MRI health insurance benefit standard and health insurance claim data. MRI examinations began as a health insurance benefit in 2005. In 2005, the indications were restricted for some diseases, but coverage for benefits in 2010, 2013, 2016, and 2018 was expanded. In 2021, the Ministry of Health and Welfare decided to apply health insurance for all MRI examinations. From 2010 to 2017, the number of MRI examinations increased by 86.7% in 2017 compared to 2010, and the amount of treatment increased by 53.5%. According to general characteristics, the number of MRI examinations was higher in women than in men. By age, the number of examinations was the highest among ages 70-79. Outpatient examinations were more frequent than inpatient examinations, and the number of examinations in the tertiary hospitals was the highest among the types of hospitals. The number of brain MRI examinations was the highest in each exam site. In December 2013, the standard of MRI was expanded for heart disease and Crohn's disease, the number of cardiac MRI and abdominal MRI examinations increased in 2014 compared to 2013. However, the number of examinations is small and not associate with the disease, it would be difficult to say that it affected the increase in the total number of MRI examinations. To assess health insurance sustainability and policy effectiveness, monitoring will be necessary.

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Psychological Systematic Consideration of Breast Cancer Radiotherapy (유방암 방사선 치료 환자의 심리의 체계적 분석)

  • Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.629-635
    • /
    • 2019
  • In term of the factors affecting psychosocial adjustment of breast cancer patients, their quality of life after surgical operation, radiation, and chemotherapy were systematically meta-analyzed. As a result, their qualities of life of the patients that had radiation therapy was the lowest right after the therapy, and gradually increased after the end of the therapy. However, after six months, their quality of life failed to reach the same level before the therapy. They had depression and side effects the most right after the therapy, and somewhat reduced them after the end of the therapy. In case of surgical operation, the more they were educated, the more they had psychosocial adjustment, and the more they had a medical examination and took out an insurance policy, the more they had psychosocial adjustment. In case of chemotherapy, their cognitive function is influenced so that they have impairments in memory, learning, and thinking stages. Since subjective cognitive impairment has a relationship with depression, it is necessary to monitor depression of chemotherapy patients. Given the results of this systematic meta-analysis, when three types of therapies (surgical operation, radiation therapy, and chemotherapy) are applied to patients with breast cancer, it is necessary to recognize their psychosocial adjustment, depression, anxiety, and quality of life in the nursing and radiation therapy fields and thereby to introduce an intervention program for a holistic approach.

Changes in CT Number and Noise Level according to Pitch in Spiral Image Acquisition (나선형영상획득에서 Pitch에 따른 CT 감약계수와 잡음의 변화)

  • Kang, SungJin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.981-989
    • /
    • 2020
  • In this study, a self-made customized phantom was used to quantitatively measure the change in CT number and noise according to the change of pitch. In order to acquire an image using the phantom, the inside of the phantom was filled with sterile distilled water. Inside the glass tube, a solution obtained by diluting the ratio of normal saline and contrast medium to 100%(NS), 400:1, 200:1, 100:1, 50:1, respectively, was placed and imaged. At this time, the pitch was divided into steps of 0, 0.35, 0.7, 1.05, and 1.4 for each dilution ratio of the solution and imaged, respectively. One-way ANOVA analysis were performed to verify whether the mean of the CT number and noise values measured in all ROIs by dilution ratio showed a significant difference according to the change in pitch. As a result of the experiment, there was no statistically significant difference in the change of the CT number according to the change in the pitch for each dilution ratio, but the noise value tended to increase with the increase of the pitch, and showed a statistically significant difference. In the spiral image acquisition of CT, noise can be changed to a significant level depending on the pitch. Therefore, it will be necessary to set the quality evaluation items and criteria for CT images using the spiral image acquisition method.

Effectiveness of the Detection of Pulmonary Emphysema using VGGNet with Low-dose Chest Computed Tomography Images (저선량 흉부 CT를 이용한 VGGNet 폐기종 검출 유용성 평가)

  • Kim, Doo-Bin;Park, Young-Joon;Hong, Joo-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.411-417
    • /
    • 2022
  • This study aimed to learn and evaluate the effectiveness of VGGNet in the detection of pulmonary emphysema using low-dose chest computed tomography images. In total, 8000 images with normal findings and 3189 images showing pulmonary emphysema were used. Furthermore, 60%, 24%, and 16% of the normal and emphysema data were randomly assigned to training, validation, and test datasets, respectively, in model learning. VGG16 and VGG19 were used for learning, and the accuracy, loss, confusion matrix, precision, recall, specificity, and F1-score were evaluated. The accuracy and loss for pulmonary emphysema detection of the low-dose chest CT test dataset were 92.35% and 0.21% for VGG16 and 95.88% and 0.09% for VGG19, respectively. The precision, recall, and specificity were 91.60%, 98.36%, and 77.08% for VGG16 and 96.55%, 97.39%, and 92.72% for VGG19, respectively. The F1-scores were 94.86% and 96.97% for VGG16 and VGG19, respectively. Through the above evaluation index, VGG19 is judged to be more useful in detecting pulmonary emphysema. The findings of this study would be useful as basic data for the research on pulmonary emphysema detection models using VGGNet and artificial neural networks.

Radioactive Concentrations in Chemical Fertilizers

  • Gwang-Ho Kim;Jae-Hwan Cho
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.195-203
    • /
    • 2022
  • Background: The aim of the present study was to determine radioactive concentrations in fertilizers known to contain essential nutrients. Results of this study could be used as basic data to monitor the impact of chemical fertilizers on the environment and public health. Nitrogen fertilizers, calcium fertilizers, sulfur fertilizers, phosphate acid fertilizers, and potassium chloride fertilizers were used in this study. Materials and Methods: Five chemical fertilizers were pulverized, placed in polyethylene containers, and weighed. The time to measure each specimen was set to be 3,600 seconds for a scintillator-based gamma-ray spectroscopy system. Concentration of gamma radionuclide was analyzed based on obtained spectra. At the end of the measurement, the spectrum file was stored and used to calculate radioactive concentrations using a gamma-ray spectrometer software. Results and Discussion: In the nitrogen fertilizer, 3.49 ± 5.71 Bq/kg of 137Cs, 34.43 ± 7.61 Bq/kg of 134Cs, and 569.16 ± 91.15 of 40K were detected whereas 131I was not detected. In the calcium fertilizer, 5.74 ± 4.40 Bq/kg of 137Cs (the highest concentration among all fertilizers), 22.37 ± 5.39 Bq/kg of 134Cs, and 433.67 ± 64.24 Bq/kg of 40K were detected whereas 131I was not detected. In the sulfur fertilizer, 347.31 ± 55.73 Bq/kg of 40K, 19.42 ± 4.53 Bq/kg of 134Cs, 2.21 ± 3.49 of 137Cs, and 0.04 ± 0.22 Bq/Kg of 131I were detected. In the phosphoric acid fertilizer, 70,007.34 ± 844.18 Bq/kg of 40K (the highest concentration among all fertilizers) and 46.07 ± 70.40 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. In the potassium chloride fertilizer, 12,827.92 ± 1542.19 Bq/kg of 40K was and 94.76 ± 128.79 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. The present study examined inorganic fertilizers produced by a single manufacturer. There might be different results according to the country and area from which fertilizers are imported. Further studies about inorganic fertilizers in more detail are needed to create measures to reduce 40K. Conclusion: Measures are needed to reduce radiation exposure to 40K contained in fertilizers including phosphoric acid and potassium chloride fertilizers.

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

A Study on Intracavitary Therapy in Cervix Cancer Using Needle for Interstitial Therapy (조직 내 삽입용 바늘을 이용한 자궁경부암의 강내치료에 관한 연구)

  • Cho, Jung-Keun;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Jeong-Koo;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.83-92
    • /
    • 2006
  • Based on the data of cervical cancer patients who were treated by the radiotherapy with concurrent chemotherapy at the radiation oncology department of National Cancer Center from January 2002 to February 2003, we have studied the method recommended by ICRU 38 to maximize the prescription dose to the planing target volume (PTV) with minimizing the dose to surrounding normal organs. Clinical stage of the patients are 1 patient for stage IB, 3 patients for IIA, 19 patients for IIB, 3 patients for IIIA, 3 patients for IIIB and 1 patient for IV. All patients took the MRI before treatment and the maximum size of the gross tumor volume were under 4cm for 17 patients and from 4 cm to 6 cm for 12 patients and above 6 cm for 1 patient. The results show that while the irradiated volume can be reduced with optimized dose distribution using PTV treatment planning (p<0.0001) when the remained tumor size is small, the surrounding normal organs will receive unnecessarily large dose when the irradiated tumor volume is relatively large. This is because there is some limitation in controling the intensity of radiation in Fletcher Williamson Applicator. To overcome the limit of applicator and to achieve the optimal dose distribution, we have virtually applied 4 needles with Fletcher Williamson Applicator for 10 patients who have relatively large tumor and studied the change in dose distribution before and after application. The results show that this new virtual treatment plan reduces the volume covered by 100 % isodose (p=0.0608, p=0.0607) and reduces the dose of normal organs (p=0.0162, p=0.008). This evidence suggest that this method is superior than the currently used method such as PTV treatment and ICRU treatment.

  • PDF

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF