• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.023 seconds

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.

Computed tomography and magnetic resonance imaging characteristics of giant cell tumors in the temporomandibular joint complex

  • Choi, Yoon Joo;Lee, Chena;Jeon, Kug Jin;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.149-154
    • /
    • 2021
  • Purpose: This study aimed to investigate the computed tomography and magnetic resonance imaging features of giant cell tumors in the temporomandibular joint region to facilitate accurate diagnoses. Materials and Methods: From October 2007 to June 2020, 6 patients (2 men and 4 women) at Yonsei University Dental Hospital had histopathologically proven giant cell tumors in the temporomandibular joint. Their computed tomography and magnetic resonance imaging findings were reviewed retrospectively, and the cases were classified into 3 types based on the tumor center and growth pattern observed on the radiologic findings. Results: The age of the 6 patients ranged from 25 to 53 years. Trismus was found in 5 of the 6 cases. One case recurred. The mean size of the tumors, defined based on their greatest diameter, was 32 mm (range, 15-41 mm). The characteristic features of all cases were a heterogeneously-enhancing tumorous mass with a lobulated margin on computed tomographic images and internal multiplicity of signal intensity on T2-weighted magnetic resonance images. According to the site of origin, 3 tumors were bone-centered, 2 were soft tissue-centered, and 1 was peri-articular. Conclusion: Computed tomography and magnetic resonance imaging yielded a tripartite classification of giant cell tumors of the temporomandibular joint according to their location on imaging. This study could help clinicians in the differential diagnosis of giant cell tumors and assist in proper treatment planning for tumorous diseases of the temporomandibular joint.

Usefulness of DECT Application for Compensation of Image Contrast Difference According to CT Contrast Agent Density (CT 조영제 농도에 따른 영상 대조도 차 보상을 위한 DECT 적용의 유용성)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.417-422
    • /
    • 2023
  • In this study, normal saline was diluted with the contrast medium at a certain ratio for the purpose of reducing the image quality poor and side effects caused by the contrast medium during CT examination. At this time, by finding the energy level of DECT that can compensate for the decrease in contrast of the image according to the degree of dilution, the usefulness of applying DECT for compensating the difference in image contrast was investigated through comparative analysis by applying SNR, CNR, and SSIM. As a result, when a dilution ratio of 4 (contrast medium): 6 (normal saline) and the energy level of DECT of 65 keV were applied, the contrast difference was the most similar to that when using the undiluted contrast medium. At this time, SNR was 813.71 ± 37.6, CNR was the highest at 921.87 ± 17.1, and SSIM index was measured at 0.851, which is the most similar to 1. The results of this study are meaningful in providing basic information for finding the appropriate dilution rate and energy level for each examination site through future clinical studies. It is believed that it can be reduced.

Chest Radiography of Tuberculosis: Determination of Activity Using Deep Learning Algorithm

  • Ye Ra Choi;Soon Ho Yoon;Jihang Kim;Jin Young Yoo;Hwiyoung Kim;Kwang Nam Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.3
    • /
    • pp.226-233
    • /
    • 2023
  • Background: Inactive or old, healed tuberculosis (TB) on chest radiograph (CR) is often found in high TB incidence countries, and to avoid unnecessary evaluation and medication, differentiation from active TB is important. This study develops a deep learning (DL) model to estimate activity in a single chest radiographic analysis. Methods: A total of 3,824 active TB CRs from 511 individuals and 2,277 inactive TB CRs from 558 individuals were retrospectively collected. A pretrained convolutional neural network was fine-tuned to classify active and inactive TB. The model was pretrained with 8,964 pneumonia and 8,525 normal cases from the National Institute of Health (NIH) dataset. During the pretraining phase, the DL model learns the following tasks: pneumonia vs. normal, pneumonia vs. active TB, and active TB vs. normal. The performance of the DL model was validated using three external datasets. Receiver operating characteristic analyses were performed to evaluate the diagnostic performance to determine active TB by DL model and radiologists. Sensitivities and specificities for determining active TB were evaluated for both the DL model and radiologists. Results: The performance of the DL model showed area under the curve (AUC) values of 0.980 in internal validation, and 0.815 and 0.887 in external validation. The AUC values for the DL model, thoracic radiologist, and general radiologist, evaluated using one of the external validation datasets, were 0.815, 0.871, and 0.811, respectively. Conclusion: This DL-based algorithm showed potential as an effective diagnostic tool to identify TB activity, and could be useful for the follow-up of patients with inactive TB in high TB burden countries.

Analysis of Learning Effects MRI Education Content based on Virtual Reality (가상현실 기반 MRI 교육 콘텐츠 학습효과 분석)

  • Jung-Hun Lee;Jae-Goo Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2023
  • In order to overcome practical limitations in installing, managing and operating MRI machines with expensive equipment, this study developed and utilized virtual reality (VR) experience education by combining virtual reality (VR) with magnetic resonance imaging devices. The Students who experienced virtual reality-based educational systems were surveyed to identify possible side effects during the experience and self-directed learning ability and academic self-efficacy surveys were conducted to analyze the impact of virtual reality-based practice on learning. In the analysis of the self-directed learning ability survey there was no difference in the average between the student group who experienced education and the student group who did not but there was a significant difference in the average for each group. Virtual Reality-based practical education is expected to provide an efficient practice system by providing new learning methods and opportunities for education that can be repeated anytime, anywhere regardless of time and space.

Dose Evaluation at The Build Up Region Using by Wedge Filter (쐐기필터 사용에 따른 선량증가 영역에서 선량평가)

  • Kim, Yon-Lae;Moon, Seong-Kong;Suh, Tae-Suk;Chung, Jin-Beom;Kim, Jin-Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.341-348
    • /
    • 2014
  • Wedge filter could use to increase the dose distribution at the hot dose regions. We evaluated dose discrepancy at surface and build region in the infield and outfield that Metal Wedge (MW) and Enhance Dynamic Wedge (EDW) were interact with photon. In this paper, we used Gafchromic EBT3 film that had excellent spatial resolution, composed the water equivalent materials and changed the optical density without development. The set up conditions of linear accelerator were fixed 6 MV photon, 100 cm SSD, $10{\times}10cm^2$ field size and were irradiated 400 cGy at Dmax. The dose distribution and absorbed dose were evaluated when we compared the open field with $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ metal wedge and enhanced dynamic wedge. A $15^{\circ}$ metal wedge could increase the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. A $30^{\circ}$ metal wedge could decrease the surface and build up region dose than using a $30^{\circ}$ enhanced dynamic wedge. A $45^{\circ}$ metal wedge could decrease by large deviation the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. The dose of penumbra region at outfield were increased on the thick side but were decreased on the thin side. It could be decrease the surface dose and build up region dose, if the metal wedge filters were properly used to make a good dose distribution and not closed the distance of surface.

T2 Relaxation Times of the Cingulate Cortex, Amygdaloid Body, Hippocampal Body, and Insular Cortex: Comparison of 1.5 T and 3.0 T (대상회 피질, 편도체, 해마체, 도피질의 T2 이완시간: 1.5테슬러와 3.0테슬러 자기공명영상장치의 비교)

  • Lee, Ho-Joon;Kim, Eung-Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.67-71
    • /
    • 2011
  • Purpose : To compare T2 relaxation times (T2) in the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex between 1.5T and 3.0T MR imagers. Materials and Methods : Twelve healthy volunteers underwent FLAIR and CPMG imaging perpendicular to the hippocampal body at both 3.0T and 1.5T. T2 was measured in the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex. The T2 relaxation time ratios of the cingulate cortex, insular cortex, and amygdaloid body to the hippocampal body were compared between 1.5T and 3.0T. Results : The mean T2 of the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex at 1.5T were $109.5{\pm}3.1$, $117.0{\pm}7.1$, $114.7{\pm}2.4$, and $111.3{\pm}2.4$, respectively; $99.7{\pm}3.8$, $100.7{\pm}4.3$, $97.9{\pm}3.4$, and $96.2{\pm}2.0$, respectively, at 3.0T. Percentage changes of T2 in the cingulate cortex, insular cortex, amygdaloid body, and hippocampal body at 3.0T with respect to those at 1.5T were -8.9%, -13.5%, -14.6%, and -13.5%, respectively. The mean T2 ratios of the cingulate gyrus, insular cortex, and amygdaloid body to the hippocampal body at 1.5T and 3.0T were 0.96 and 1.02 (p = 0.003); 1.02 and 1.03 (p>0.05); 0.97 and 0.98 (p>0.05), respectively. Conclusion : T2 decrease in the cingulate cortex was less than the amygdaloid body, insular cortex, and hippocampal body at 3.0T. The mean T2 ratio of the cingulate gyrus to the hippocampal body was significantly different between 1.5T and 3.0T.

A Study of the Improvement of Clinical and Practical Trainings in the Education of Radiologic Technologists (방사선사(放射線士) 교육(敎育)의 임상실습(臨床實習) 개선(改善)에 관(關)한 연구(硏究))

  • Lee, Man-Koo;Kang, Se-Sik;Yoon, Han-Sik;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.117-129
    • /
    • 1983
  • This study, in order to improve clinical and practical trainings in the education of radiologic technologists, applies to 76 medical institutions of 91 ones which are used as the hospitals of clinical and practical training in 9 existing junior colleges except 3 new ones of 12 ones throughout all over the country from November 1, in 1982 to April 30, in 1983. And the purpose of this study is to research the percent conditions of basic practical trainings and clinical ones enforced in each college, and the percent conditions, equipments, contents, and opinions in clinical and practical trainings enforced in each hospital. The results are summarized as follows; 1. In the case of junior colleges in the whole country the curriculum of basic practical trainings averages 336.66 hours and the limits are between 120 and 510 hours. The actual hours in practice average 140 hours and the limits are between 60 and 240 hours, which correspond to 41.58% of the curriculum of basic practical trainings. 2. There were three junior colleges among nine that had a reserved hospital for clinical and practical trainings(only 33.33%). 3. The period of the practice was almost vacation in 4 junior colleges. The practice was conducted only for students to want the practice(44.45%), junior colleges that all students in them conducted the practice was 2 junior colleges and presented 22.22%. 4. In the field of students engaging in the practice, each field of radiation therapy and nuclear medicine presented 16.5%, 20.3% and almost students didin't have experience for the practice. 5. In medical institutions the educational institutions for intern showed 67.11%. Hospital with radiologist showed 26.32%. Radiotechnologist who had experience below 5 years presented 60.17%. 6. In the equipment for radiation diagnosis, each hospital had no difference. The number of hospitals passessing diagnostic equipments above 125 KVP was 56.26%. But radiation therapy equipment and nuclear medicine equipment had extremely low rate. 7. In the diagnosis of patient in the practice hospital, conventional radiography-to Skull, Chest, Abdomen, Skeleton, Urogenital system-reached the criterion. But special radiography was comparatively low. There appeared low rate, 32.89% in the field of nuclear medicine, 15.79% in the field of radiation therapy. 8. Students who carried out the practice were 1-89 students, days in practice were 1-30 days. There were differences in that point among among hospitals. Junior colleges conducting the practice were 2 colleges per hospital. Scope of the object were 1-8 junior colleges. 9. The practice conducted for the request of the colleges presented 72.37%, in addition, The prctices were conducted for growth of the younger generation and the same coperation with the colleges establishment of sisterhood with the colleges, relationship with students. 10. The practice conducted without the establishment of plan presented 59.21% The need for guiding book to the practice and evaluating was recognized over 90%. 11. In the relation between the practice with achievement of credit. There were big differences in opinion between hospitals-Group and the colleges-Group; hospital-Group had opinion that must follow achievement of credit with the practice. The colleges-Group had opinion that must conduct the practice after achieving credit. 12. After conducting the practice, in the practice leaders satisfaction degree dissatisfactory opinion presented the most rate 80.26%. Very much satisfactory opinion, as one hospital, presentd only 1.32%. 13. Both hospitals-Group and the colleges-Group had an opinion that the practice leader must have actual experiences, lectures and achievement, an opinion that actual experiences is over 5 years. 14. In the guide of human relation, cooperation, responsibility, courtesy to patients. Both hospitals-Group and the colleges-Group had an opinion that the guide must be involved in the period of the practice and must be instructed.

  • PDF

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention (관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가)

  • Kang, Yeong-Han;Kim, Bu-Sun;Park, Jong-Sam
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.213-221
    • /
    • 2010
  • The Purpose of this study was to determine the effective dose to an average patient from Coronary Angiography (CA) and Percutaneous Coronary Intervention (PCI). And to estimate the lifetime attributable risk (LAR) of cancer associated with radiation exposure from CA and PCI. The dose-area product (DAP) values to the patient were recorded from 60 CA and 58 PCI. A Monte Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Lifetime attributable risks were estimated with models developed in the National Academies' Biological Effects of Ionizing Radiation VII report. The mean DAP values was $53.76\;Gy{\cdot}cm^2$ for CA and $165.82\;Gy{\cdot}cm^2$ for PCI. Mean effective dose were 1.28 mSv in CA, 3.94 mSv in PCI. Results of Calculate organ dose, lung doses was 2.17 mSv in CA and 6.71 mSv in PCI. Female breast doses was 5.45 mSv in CA and 16.82 mSv in PCI. LAR estimates for CA varied from 1 in 1,508 for man to 1 in 1,357 for women. In PCI procedure varied from 1 in 553 for man to 1 in 482 for women. DAP can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. These dose estimates derived from our simulation models suggest that CA and PCI are associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, PCI than for man, CA.