• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.025 seconds

A Study on the Feasibility of a National Practical Examination in the Radiologic Technologist (방사선사 실기시험제도 도입의 타당성 연구)

  • Son, Soon-Yong;Kim, Tae-Hyung;Min, Jung-Whan;Han, Dong-Kyoon;Ahn, Sung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2149-2162
    • /
    • 2011
  • Currently practical examination can't function as a practical technique ability evaluation', so there is a contradiction which even though a radiologist passed an examination for license, he has to complete a training course. To improve this problem, this study tried to deduce the most reasonable plan from the analysis of propriety of currently practical examination and what improvement points are. This conduct study was compared and analyzed the performance or practical examination of radiology from leading advanced countries within the samples of 634 radiologists, 56 professors of radiology. From the result of this study, it showed that radiology practical examination was difficult to be substituted by radiology clinical training since there were some critical differences between conditions of domestic and advanced countries. Therefore, the introduction of the radiology practical examination is inevitable and necessary. However the currently practical examination can't evaluate actual practical ability, so we could conclude that converting it into OSCE (objective structured clinical examination) form is essential. From now on, we should consider more about an in-depth study on types of advanced practical examination and how to suggest and present them in order to become an one of the advanced countries for radiologic technologist.

Changes in Compliance Rates of Evaluation Criteria After Healthcare Accreditation: Mainly on Radiologic Technologists working at University Hospitals in Daejeon Area (의료기관인증평가 전후 인증기준 준수율의 변화 : 대전지역 대학병원의 방사선사를 중심으로)

  • Ko, Eun-Ju;Lee, Jin-Yong;Bae, Seok-Hwan;Kim, Hyun-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.281-290
    • /
    • 2013
  • This study aimed to assess whether the changes in compliance rates of evaluation criteria after healthcare accreditation among radiologic technologists working at four university hospitals which had acquired healthcare accreditation in Daejeon metropolitan area. In this study, the evaluation criteria of healthcare accreditation were reclassified and reevaluated to three areas which include patient safety, staff safety, and environmental safety. Each area has eight, three, and five questions, respectively. Each compliance rate was quantitatively measured on a scale of 0 to 10 before and after in this study. The result shows that the overall compliance rates were decreased on all areas compared to the time healthcare accreditation was obtained. The compliance rate of hand hygiene was drastically reduced. To maintain the compliance rates, not only individuals but healthcare organizations should simultaneously endeavor. In particular, healthcare organizations should make an effort to provide continuous education opportunity to their workers and supervise the compliance regularly.

Investigation of the Time Required for General Radiography (일반 방사선검사의 소요 시간 실태조사)

  • Lim, Woo-Taek;Joo, Young-Cheol;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.255-262
    • /
    • 2022
  • In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.

Synchronous thyroid carcinoma and squamous cell carcinoma. A case report (동시발생한 갑상선 암종과 편평세포암종의 증례보고)

  • Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.221-226
    • /
    • 2006
  • Thyroid carcinoma occuring as a second primary associated with head and neck squamous cell carcinoma (SCC) is unusual. This report presents a synchronous thyroid carcinoma and squamous cell carcinoma in the anterior palate region of a 41-year-old man. The clinical, radiologic, and histologic features are described. At 10-month follow-up after operation, no evidence of recurrence and metastasis was present.

  • PDF

The Job Consciousness for Radiological Technologists in Korea, Canada, and Australia (한국, 카나다 및 호주 방사선사의 직업의식)

  • Han, Eun-Ok;Kwon, Deok-Mun;Park, Kwang-Hun;Choi, Seung-Yoon;Jung, Chung-Hyun;Bae, Sang-Il;Oh, Chang-Woo
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.225-234
    • /
    • 2009
  • This study attempts to provide basic information on overseas employment to the radiological technologists and students majoring in radiology in Korea who consider the overseas employment by investigating the job consciousness for radiological technologists in Canada and Australia which have a high level of interest for overseas employment and want to compare their status with that of Korean radiological technologists. This study was performed by visiting hospitals such as Prince George Regional Hospital, 1475 Edmonton Street, Prince George, BC, Canada on August 13, 2007, Alfred Hospital, Commercial Road Melbourne 3004, Australia on August 4, 2008, and other Korea hospitals that show the similar scale as Canada and Australia on September 10, 2007. The results were summarized as follows : 1. Differences were observed in this sexual composition, such as 18 males (90%) in Korea, 14 females (73.7%) in Canada, and 25 females in Australia (86.2%). 2. The item of 'aptitude' which is one of the most important criteria, showed the highest level in Korea, Canada, and Australia, and the second most considered item was 'salary'. 3. In the values in jobs, the items of 'economic self-sufficiency', 'recognized by others', and 'establishing a social position' represented high levels in Korea, and the items of 'like the job itself', 'establishing self-actualization', 'feel the meaning of life', and 'make new friends' showed high levels in Canada and Australia. 4. Regarding the item of 'a job is important as much as a marriage', 'Yes' showed high level in Korea, and 'No' showed high levels in Canada and Australia. 5. Radiological technologists in Korea demonstrated a low level in the job consciousness compared to those of Canada and Australia. Although this study shows some limitations for showing whole idea of radiological technologists due to the lack of the scope in samples for each country as a practical manner, this study can be regarded significant to compare some countries that have interests in overseas employment.

  • PDF

Requirements in the Overseas Employment and Domestic Connected Education for Radiological Technologists : Refers to Students Enrolled in the Department of Radiation (방사선사 해외취업 및 국내 연계교육에 대한 요구도 : 방사선과 재학생을 중심으로)

  • Han, Eun-Ok;Kim, Boo-Soon
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • This study investigated the realities of information acquirements and its requirements in the overseas employment and domestic connected education for students at the department of radiation in order to provide basic information for developing the standard educational curriculum for future internationalization in the education of radiation and presenting its direction. The investigation implemented in this study was performed through a questionnaire with 688 students enrolled in the department of radiation. The conclusion of the investigation is summarized as follows : The answers for the question of 'No acquirements in the information of the overseas employment and connected education for radiological technologists' were 487 students (70.8%), and the reason that 'There are no chances in related education' was the highest rate, 424 students (61.6%), of the answers. In the education for the overseas employment, the answers for the question of 'Select a connected education program in school instead of study abroad' were the highest rate, 436 students (63.4%). The most concerned country for the overseas employment was 'Australia', 247 students (35.9%). As a result, answers for the interest, participation, need, and hope for the overseas employment showed high rates even though they demonstrated a low recognition level in the overseas employment. In addition, it is necessary to strategically plan an education program for this issue because all participants agree with the current stream.

  • PDF

Factors Affecting the Turnover Intention for Radiologic Technologists Working in Private Clinic and University Hospital in Daejeon City, Korea - (병.의원에 근무하는 방사선사들의 이직의사에 관련된 요인 - 대전광역시를 중심으로 -)

  • Kim, Young-Ran;Lee, Tae-Yong;Cheon, Hae-Kyung
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.371-380
    • /
    • 2009
  • This study was executed to find out the intensity of turnover intention and its associated factors of radiologic technologists who worked for private clinic and university hospitals in Daejoen. Such variables as social and demographic characteristics, job-related features, job stress, job satisfaction, job performance, organizational commitment and turnover intention were investigated based on the survey of randomly sampled 400 radiologic technologists. The results are summarized as follows. 1. College graduates of private clinic workers were significantly higher than junior college graduates of them in the mean score for turnover intention. And low age groups, unmarried group, no religion group, low job career groups and low income groups of university hospital workers were significantly higher than high age groups, married group, religion group, high job career groups and high income groups of them respectively in the mean score for turnover intention. 2. Private clinic and university hospital workers' low and high groups in the variables of job demand, job control, supervisor support, job satisfaction, organizational commitment showed significant difference in the mean score for turnover intention. specially private clinic workers' low and high groups in the variables of coworker support, job performance showed significant difference in the mean score for turnover intention. 3. A hierarchial multiple regression analysis was conducted to catch the influence of related variables on turnover intention according to private clinic workers and university hospital workers. As a result of the analysis, the higher the degrees of education and job demand were and the lower the degree of job satisfaction was for private clinic workers, the higher the degree of turnover intention was. And the lower the degrees of age, job career, job satisfaction and organizational commitment were for university hospital workers, the higher the degree of turnover intention was. In conclusion, it was found that job demand and job satisfaction for private clinic workers and job satisfaction and organizational commitment for university hospital workers influenced on turnover intention.

  • PDF

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

Development of Radiation Shielding Sheet with Environmentally-Friendly Materials; II: Evaluation of Barum, Tourmaline, Silicon Polymers in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발; II: 바륨, 토르말린의 실리콘 폴리머 차폐 시트의 성능 평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • We developed an alternative radiation shielding material which is economical and has high protection efficiency. We validated the material in the form of sheet to make an apron. We increased the rate of barium and mixed tourmaline into silicon to improve the flexibility and protection rate of the sheet. The results showed that the shielding effect at low radiation energy is good enough with both 5 mm and 7 mm thickness. In the future, we will perform a quantitative evaluation of the reproducibility, volumetric efficiency, and porosity in mixing the ingredients.