• Title/Summary/Keyword: Radiographic method

Search Result 373, Processing Time 0.023 seconds

Decision-Making and Principle of Management in Periprosthetic Femoral Fracture after Total Hip Arthroplasty (고관절 치환술 후 삽입물의 안정성 판단과 대퇴 삽입물 주위 골절의 치료 원칙)

  • Kim, Beom-Soo;Lee, Kyung-Jae;Min, Byung-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.200-207
    • /
    • 2021
  • Periprosthetic femoral fractures remain as one of the most challenging complications following total hip arthroplasty. A thorough clinical and radiographic evaluation, precise classification, and understanding of modern management principles are essential to obtain optimal results for these fractures. The Vancouver classification system is a simple, effective, and reproducible method for the planning treatments of these injuries. The fractures associated with a stable femoral stem can be treated effectively with osteosynthesis, but periprosthetic femoral fractures associated with a loose stem require revision arthroplasty. This paper describes the principle of the treatment of patients with periprosthetic femoral fractures and how to assess the stability of the femoral stem.

Analysis of Importance, Understanding Level and Needs by Subject of College Students Preparing for Radiological Technologists National Examination (방사선사 국가시험 준비를 위한 대학생들의 과목별 중요도와 이해도 수준 및 요구도 분석)

  • Young-Lock, Kim;Jae-Hong, Jung;Dae-Gun, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.53-61
    • /
    • 2023
  • The aim of this study analyzed the important level (IL) and understanding level (UL) including the Borich's need for students preparing of the national examination for radiological technologists at online open chatting room. A total of 254 survey were collected from a total of 1,016 students who used open chatting room from December 13 to December 16, 2022. A general characteristics were the age, gender, curriculum (3 or 4 years), grade and area. The IL, UL, learning satisfaction (LS), learning achievement (LA) and intention to continue using (ICU) were analyzed by using the 5 point Likert scale. There was no significant difference the LS, LA, and ICU according to general characteristics (p>0.05). There was a statistically significant difference a total of sixteen subjects based on the t-test results of the response values from the IL and UL (p<0.05). The total of ten subjects with the highest priority in the Locus for Focus models were the Ultrasonography, Human anatomy, Magnetic resonance imaging, Radiation therapy, Cardiovascular and intervention, Computed tomography, Human physiology, Radiographic imaging, Fluroscopic radiography, and Nuclear medicine) that the Borich's need was also the same as the top 10 ranked subjects. The LS (4.23±0.72), LA (4.18±0.73), and ICU (4.15±0.78) for open chatting room were high. This study identified the subjects most needed by college students by the Borich's need analysis. First, it is necessary to provide intensive education on subjects with high scores that are most needed by college students. Second, it is necessary to improve the teaching method for subjects with low need and low level of understanding.

Correlation of Cervical Disc Degeneration with Sagittal Alignments of Cervical Spine (두경부 시상면 정렬과 경추 추간판 퇴행성 변화와의 상관관계)

  • Jeon, Dae Geun;Park, Jinyoung;Park, Jung Hyun;Yun, Wang Hyeon
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • Objective: To determine the relationship between cervical sagittal parameters and the degree of the cervical disc degeneration at each cervical level by using cervical plain radiographs and disc degeneration grading. Method: This study analyzed 110 patients with posterior neck pain. Cervical radiographic measurements included the occipito-cervical (O~C2) angle; sagittal Cobb angles of C1~C2, C2~C7; and sagittal vertical axis (SVA) of C1~C7 and C2~C7. The degenerations of cervical discs at each level were evaluated through Pfirrmann grading system by magnetic resonance images of the cervical spine. The correlations between the cervical sagittal measurements and the disc degeneration at each level were analyzed by Spearman's correlation. Results: A significant correlation was found for the C2~C7 angle with disc degenerations at C2~C6 levels. O~C2 angle was correlated significantly with disc degenerations at C2~C4 and C5~C7 levels. There was significant correlation between C1~C2 angle and disc degeneration at C6~C7 level. No significant relationship was found between the cervical SVA and the cervical disc degeneration at all cervical levels. Conclusion: Cervical sagittal parameters representing cervical angles (C2~C7, O~C2, and C1~C2 angles) were significantly correlated with the degree of the cervical disc degeneration. These findings suggest that the loss of the natural cervical lordosis rather than loss of natural SVA could be correlated with progression of the cervical disc degeneration.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

CLINICAL STUDY ON SURGICAL MANAGEMENT OF MANDIBULAR CONDYLAR FRACTURES (하악 과두 골절의 외과적 처치에 관한 임상적 연구)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.2
    • /
    • pp.167-180
    • /
    • 1997
  • 79 surgically managed mandibular condylar fracture patients included the 25 patients treated with Dr, Nam's method were analysed the postoperative resluts in Oral and Maxillofcial Surgery, School of Dentistry, Wonkwang University since 1993 to 1995. Mean patient's age is 32.5 years (range, 8 to 65 years), and follow-up periods were a minimum of 3 months to 28 months. 19% condylar fractures were associated with mostly symphysis portion. According to the patient's age, severity of condylar fractures, clinical signs and symptoms, radiographic findings, treatmenet plans had been performed. Rigid fixation have performed greatly, and then fragment removal of fractured mesial pole of proximal segment of the condylar and little cases of reshaping and eminoplasty and lag screw have been applied. Two cases of the both condylar resorption and deviated condyle posteriorly in Dr. Nam's method. None of infection or necrosis signs of treated condyle surgically. In my opinion, whenever possible, displaced condylar fracture can be managed surgically with rigid fixation, but not Dr. Nam's method. Usually if perform the surgical management of condylar fractures you should maintain maxillomandibular fixation for 2 weeks, or more and has to follow-up functional mandibular exercise should be kept continuously.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Chip-based isothermal amplification method for EGFR gene mutations in lung cancer (칩 기반 등온 증폭반응법을 이용한 폐암에서의 EGFR 유전자 돌연변이 검출 시스템 개발)

  • Ahn, Young-Chang;Park, Su-Min;Seo, Jae-Won;Yoon, Il-Kyu;Jung, Duck-Hyun;Lee, Eun-Young;Nam, Youn-Hyoung;Jang, Won-Cheoul;Seung, Kwon Pil;Kim, Jong-Wan
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.498-503
    • /
    • 2009
  • Lung cancer is the main cancer on the world today, due to the high case fatality. Lung cancer can devide into two major types, such as small-cell lung cancer (SCLC) and non-small-cell lung cancer (NSCLC). Mutations in the epidermal growth factor receptor (EGFR) have been described in patients with advanced NSCLC. Mutations in the EGFR are associated with clinical and radiographic responses to EGFR tyrosine kinase inhibitors gefitinib and erlotinib. Thus, the detection of EGFR mutation can offer an effective information in clinical decision-making. In this study, We developed very simple, cheep and rapid mutation detection system by chip-based isothermal amplification method. The method described here has shown the advantages of rapid amplification, high sensitivity, and specificity. Also, it will be useful for rapid and reliable clinical diagnosis of EGFR mutation.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position (반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구)

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Park, Dae-Sop;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.64-66
    • /
    • 2004
  • When examing patients with DRs it is necessary to remove bad pixels and lines and to correct non-uniform offsets and x-ray field. For non-uniformity correction a flat field x-ray image is needed, and to obtain it the center of detector is usually aligned with the focal spot of the x-ray tube, which is conserved when examing patients to preserve the flat field. In some of radiographic techniques, however, it is necessary to move the x-ray tube off the center position of detector or tilt the detector. We investigated the effect of detector tilting on the non-uniformity correction, and propose a method to reduce the effect using a new algorithm. The flat field of X-ray in the DR detector could be guaranteed with this result.

  • PDF