• 제목/요약/키워드: Radiographic film

검색결과 122건 처리시간 0.039초

관골구 골절에서의 전산화단층촬영술의 진단적 가치 (Diagnostic Value of Computed Tomography in Acetabular Fracture)

  • 김선용;박복환;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 1988
  • 골절의 모양, 범위 및 골편의 해리의 정도를 C.T.로서 잘 결정할 수 있었다. 고관절을 비롯한 기타 골반골의 골절과 연부 조직손상 정도를 잘 알 수 있었다. 고식적인 단순 Z-선 촬영으로 발견이 안 되었던 고관절내 골편의 유 무를 잘 관찰할 수 있었다. 골반골 골절이 있는 움직이기 어려운 환자에서 검사가 쉽고, 용이하게 이루어질 수 있었다. 수술후 관절강내 골편이나 개방성복술에 대한 평가를 잘 할 수 있었다.

  • PDF

흉부X선촬영(胸部X線撮影)에 있어서 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究) (A Study on the Chest Radiography for Reducing Exposure Dose)

  • 이만구;윤한식;이종석;이선숙;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.41-49
    • /
    • 1996
  • We have been used super sensitive screen/film system which is thought to be the limit of sensitivity, however, we think this method is not satisfactory. As a general radiographic rule, reduction of exposure is inconsistent with improvement of image quality, but it is necessary to challenge this rule to get better method. We tried air gap method for minimal diffuse lung shadow which is difficult to find out by our routine method. As a result, air gap method with super sensitive screen/film system(SRO 1000/TMH) showed lower exposure dose, 50% of our routine system(SRO 750/SRH with grid), and better image quality for pulmonary pattern in the lower lung field.

  • PDF

디지털영상을 이용한 치근이개부 실험병소의 판독능에 관한 연구 (An experimental study on the readability of digital images in the furcal bone defects)

  • 강형욱;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.71-77
    • /
    • 2003
  • Purpose : To evaluate and compare the efficacy of digital radiographic images in the detection of bone loss at the bifurcation area of the mandibular first molar with traditional film-based periapical radiographs, Materials and Methods : One dried human mandible with minimal periodontal bone loss around the first molar was selected and an artificial alveolar bone defect at the bifurcation area was serially prepared over 18 steps. Images were taken using a direct CCD-based system and with F-speed periapical films. The images were evaluated by seven interpreters (3 radiologists, 3 periodontologists, and 1 general dentist) using a 5-point confidence rating scale. Results : The readability of both periapical radiographs and digital image increased as the size of the artificial lesion and exposure time increased (p < 0.05). Periapical radiographs offered greater readability of smaller bone defects than digital images, and the coefficient of variation of mean score between periapical radiographs and digital images showed a significant difference. Conclusion : The experimental results indicate that a significant difference in the coefficient of variation of mean score exists between periapical radiographs and digital images, and that traditional film-based periapical images offer greater readability of smaller bone defects than digital images can presently offer.

  • PDF

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석 (Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor)

  • 박성태;윤종현;박광보;오용호;이형진;인경환;김건중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

X-Ray TDI Camera를 이용한 알루미늄 주강품 검사장치 개발 (Development of Inspection System for Aluminum Castings with X-Ray TDI Camera)

  • 남문호;박성욱;김창호;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1734-1735
    • /
    • 2011
  • In case of inspection on aluminum castings, traditional RT (Radiographic Testing) method have been utilized for its advantages in interpretation, cost and perpetual storage. But it has disadvantages like time consumption in film processing, low efficiency in storage and environmental pollution. In this thesis, a DRS (Digital Radiography System) utilizing X-Ray TDI Camera (Time Delay and Integration Camera) is developed. Inspections on aluminum castings are performed using the developed Digital Radiography System, DRS and reviewed if newly developed system can substitute for the traditional method.

  • PDF

Desmoplastic Fibroma of the Skull

  • Kim, Kwan-Sik;Noh, Jae-Sub;Chung, Bong-Sub;Shin, Mi-Kung
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권5호
    • /
    • pp.393-395
    • /
    • 2006
  • Desmoplastic fibromas are rare intraosseous bone tumors. They are benign but locally aggressive and frequently found in the long bones and mandible. We report radiographic and histopathologic finding of a case desmoplastic fibroma involving right temporal skull bone. A 53-year-old woman presented at our hospital complaining of continuous right side headaches for a year. Simple skull X-ray film showed $3{\times}2.5cm$ lytic lesion with mild sclerotic margin on right temporal area. A large craniectomy 1cm lateral to margin was fashioned. The resected mass showed encapsulated mass colored white gray. Histologic diagnosis was compatible with that of a the desmoplastic fibroma. There was no evidence of recurrence during the 15months of follow-up period.

동판을 이용한 Spot 촬영법에 관한 새로운 시도 (A New Attempt on Spot Radiography Using Cu Mask)

  • 김정민;강홍석;이인자;신화수;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.37-41
    • /
    • 1987
  • Authors could recognize surrounding areas induding target area by the observable film density with spot radiography using Cu mask and also, radiographic images maintained high quality. Spot radiography has been utilized for a long time for the purpose of observing detail image by the control of scattered radiation. But it has been difficult to know body part in general spot radiography. Therefore it is thought that attempt to use Cu mask in spot radiography is very advantageous in a clinical examinations.

  • PDF

Diagnostic Imaging of Recurred Mandibular Ameloblastoma with Large Soft Tissue Involvement

  • Park Kwan-Soo;Lee Sam-Sun;Jeon In-Seong;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제30권4호
    • /
    • pp.281-285
    • /
    • 2000
  • An uncommon case of a patient with recurrent mandibular ameloblastoma involving various adjacent soft tissues is presented with plain film radiography, computed tomography and magnetic resonance imaging (MRI) and bone scan. The tumor involved mandible and eroded several bones including foramen ovale. This case shows that although an ameloblastoma primarily affect mandible, exact radiographic evaluation of tumor extent will assist the surgeon in the progress of rational approaches to the management of ameloblastoma.

  • PDF

비연질환(부비동질환)鼻淵疾患(副鼻洞疾患)의 한방치험(韓方治驗) 12례(例) (12 Cases of Paranasal Sinusitis by Oriental Medicine)

  • 김중호;김윤범;채병윤
    • 대한한의학회지
    • /
    • 제15권2호
    • /
    • pp.113-121
    • /
    • 1994
  • We report 12 cases of paranasal sinusitis by the treatment of oriental medicines. Showing discharge from the nose. paranasal sinusitis is termed BIYEON(鼻淵) in the oriental medicine. Most of patient took GAMIBANGPUNGTONGSEONGSAN(加味防風通聖散). reported effect of antiphlogosis. antihistamine and antibiosis, for about five months. As a result the symptoms of paranasal sinusitis subsided. The radiographic diagnosis of sinusitis is generally based on opacification of the paranasal sinuses. Most of patients change the opacity of the maxillary sinuses on X-ray film in Water's view and Caldwell view by the treatment of Oriental medicine. We conclud that herbal medicines effect paranasal sinusitis.

  • PDF