• Title/Summary/Keyword: Radioactivity measurement

Search Result 137, Processing Time 0.029 seconds

Development of Remote Data Analysis System for the Joint Use of Equipments (분석기기지원을 위한 원격 데이터 분석 시스템 개발)

  • 최인식
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.3
    • /
    • pp.94-106
    • /
    • 1999
  • In Korea Basic Science Institute(KBSI) the remote data analysis system is developed for the joint use of advanced equipments. This system enables the researchers to access the datas which are produced at KBSI and analyse them by Java program on the Web,. Except Web browser such as Internet Explorer or Netscape Navigator no additional softwares are required for analysing data. We have developed remote data analysis systems for five major equipments which KBSI supports for the researchers, The systems which are developed are those for NMR spectrometer High Reso-lution Tandem mass Spectrometer Microscopic Imaging System DNA Sequencer and Natural Ra-dioactivity Measruement System, These programs work on any computer platform and any operat-ing system only if the internet is available. This remote data analysis system will be served as a part of Collaboratory the remote collaborative system.

  • PDF

The Variation of Radiocarbon-14 Content in the Atmosphere

  • Kyung Rin Yang
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.370-377
    • /
    • 1971
  • The Carbon-14 content in surface air at Seoul, Korea, was measured from February 1970 to August 1971 and a Larix Leptolepis, Gordon tree (Ip-Gal Namu) grown at Kwang-Nung, Kyunggi-Do, Korea, having 37 growth rings, was assayde for $^{14}C$. From the results of the surface air study, it was calculated that during the above period the inventory of excess $^{14}C$ in the atmosphere decreased with a half-time of 4.6 years. The overall yearly decrease was also checked. The tree-ring study showed that the tree's atmosphere was affected by $^{14}C$ from nuclear tests after 1956. In one study, atmospheric $CO^2$ samples were collected bi-monthly by the absorption of $CO^2$ in alkaline hydroxide solution. In the other, 5 year annual growth rings were assayed for radiocarbon. For the radioactivity measurement, carbon atoms in samples were converted to carbon atoms of benzene. The resulting benzene was taken as primary solvent for liquid scintillation counting.

  • PDF

Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure (의료기관 지하시설의 라돈가스 측정과 내부피폭 조사)

  • Song, Jea-Ho;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.231-235
    • /
    • 2011
  • Radium is rock or soil of crust or uranium of building materials and thorium after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like mine or basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. Radium sheath of medical institution treat person's life is possible big danger to professional regarding radioactivity who has much amount exposed radioactivity and weaker immune patient. so we do this test. Using measuring instrument at test is real time radium measuring instrument, Professional Continuous Radon monitor, and measuring places are basement first floor and second floor of two hospitals and measure from 10 a.m to 3 p.m. Measurement result of Professional Continuous Radon monitor is minimum 14.8 Bq/$m^3$ to maximum 70.3 Bq/$m^3$ and show domestic baseline below 148 Bq/$m^3$, effective dose-rate is minimum 0.296 mSv to maximum 1.406 mSv that show 2.4 mSv, 10~58.3% level, exposed radiation amount from nature radiation one year.

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

A Study on Minimum Detection Limit of Environmental Radioactivity in HPGe Detector (HPGe 검출기에서 환경방사능측정의 검출하한치에 관한 연구)

  • Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • Based on basic concept of detection limit, sample measurement time & background measurement time was considered, and MDA values according to background measurement time and sample measurement time in land samples(river soil, surface soil, drinking water, underground water, surface water, pine leaf, mugwort) analysis among environmental samples were compared. Seeing the water sample analysis result, it was shown that most of the samples were not detected, and most of the samples in land specimen analysis showed to be below the detection limit of "Ministry of Education, Science and Technology Announcement Je-2008-28-ho", but $^{137}Cs$ which is one of artificial radioactive nuclide was detected in some samples. It can be traced back to 1950s and 1960s when nuclear tests were carried out in atmosphere and catastrophic Chernobyl atomic power station accident that caused fallouts in the sky, and this is common level of detection that can be observed worldwide. Seeing the result that the $^{134}Cs$(which is a isotope of $^{137}Cs$, and it has relatively short half life) was not detected in all samples, it can be considered it doesn't affect to the operation of atomic power station.

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.