• 제목/요약/키워드: Radio meter

검색결과 49건 처리시간 0.02초

Binary CDMA 기술을 이용한 무선 원격검침 시스템 구현 (Implementation of Wireless AMR System using Binary CDMA)

  • 권대길;조진웅;홍대기
    • 반도체디스플레이기술학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2013
  • This paper presents the AMR (Automatic Meter Reading) system using the binary CDMA (Code Division Multiple Access) radio technology. The binary CDMA is the new radio technology in domestic research. Main implementation topics includes the binary CDMA remote meter reading system, the wireless piconet configuration for the wireless automatic meter reading, and the transmission scheduling for sending and receiving data. Also, the wireless packet data encryption is very important topics for the wireless automatic meter reading. The proposed AMR system is implemented as a pilot project in Jeju and Gangwon. It can be seen that the wireless remote reading using the binary CDMA wireless technology can be applied to the AMR system.

424 MHz 소출력 무선주파수 전파특성 측정 및 분석 (The Measurement and Analysis of Radio Characteristic of 424 MHz Short Range Wireless Frequency)

  • 임용훈;최효열;오규환;이범석;현덕화
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.437-442
    • /
    • 2005
  • This paper deals with the measurement and analysis of radio characteristic of 424 MHz for using the automation of transmission and supply of electric power, ana automatic meter reading(AMR). Normally radio propagation characteristic is the base of system design, performance evaluation and choice of position of the base station in wireless communication. It is the most accurate way to design a base station through practical measurements, but it costs much time, money and engineers. So, we developed 424 MHz short range wave propagation model for AMR service.

  • PDF

PERFORMANCE OF THE SRAO 6-METER RADIO TELESCOPE

  • KOO BON-CHUL;PARK YONG-SUN;HONG SEUNG SOO;YUN HONG-SIK;LEE SANG-GAK;BYUN DO-YOUNG;LEE JUNG-WON;CHOI HAN-KyU;LEE SANG-SUNG;YOON YOUNG-ZOO;KIM KEE-TAE;KANG HYUN WOO;LEE JUNG-EuN
    • 천문학회지
    • /
    • 제36권1호
    • /
    • pp.43-48
    • /
    • 2003
  • We introduce and describe performance of the 6-meter telescope of Seoul Radio Astronomy Observatory (SRAO). All the softwares and instruments except the antenna structure and its driving system are developed for ourselves. The SIS mixer type receiver resulted in the receiver noise temperature less than 50 K (DSB) over the whole 3-mm radio window. An autocorrelation spectrometer, developed first in Korea, provides maximum 50 MHz band width over 1024 channels. Antenna surface is measured and adjusted using template method and radio holography which resulted in a superb surface accuracy bet-ter than 30${\mu}m$. Accordingly, the aperture and beam efficiences amount to $70\%$ and $75\%$, respectively, largely independent of frequency in the 85 - 115 GHz range. It is also found that telescope pointing errors are less than 10" in both azimuth and elevation and that antenna gain is almost constant against elevation greater than $20^{\circ}$, without adjusting sub-reflector position. The SRAO 6-meter telescope is now fully operational and all these characteristics verify that observations are carried out with high precision and fidelity.

Adaptive algorithm for optimal real-time pricing in cognitive radio enabled smart grid network

  • Das, Deepa;Rout, Deepak Kumar
    • ETRI Journal
    • /
    • 제42권4호
    • /
    • pp.585-595
    • /
    • 2020
  • Integration of multiple communication technologies in a smart grid (SG) enables employing cognitive radio (CR) technology for improving reliability and security with low latency by adaptively and effectively allocating spectral resources. The versatile features of the CR enable the smart meter to select either the unlicensed or the licensed band for transmitting data to the utility company, thus reducing communication outage. Demand response management is regarded as the control unit of the SG that balances the load by regulating the real-time price that benefits both the utility company and consumers. In this study, joint allocation of the transmission power to the smart meter and consumer's demand is formulated as a two stage multi-armed bandit game in which the players select their optimal strategies noncooperatively without having any prior information about the media. Furthermore, based on historical rewards of the player, a real-time pricing adaptation method is proposed. The latter is validated through numerical results.

배터리 수명을 고려한 원격검침 모듈 설계 (Design of a Remote Meter Reading module considering battery life time)

  • 정원창;구명모;장성주;김상복
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.45-50
    • /
    • 2008
  • 계량기의 지침을 인식하고 수도 관리 사업소로 데이터를 전송하기 위한 검침모듈은 전원을 전력선으로 이용할 수 없다. 따라서, 검침모듈은 배터리를 이용해야 하므로 주기적으로 소모된 배터리를 교체하는 유지보수 문제가 발생한다. 유지보수 비용을 절감하기 위해 전원 소모를 줄이면서 무선으로 데이터를 전송 할 수 있는 방안이 필요하다. 본 논문에서는 효율적인 전원관리를 통하여 배터리 소모량을 줄이면서 고객계량기의 지침을 자동으로 인식하고, RF를 이용하여 검침 데이터를 전송 할 수 있는 원격검침 모듈을 설계하였다.

  • PDF

전자식 계기 IEC 61000-4-6 EMS 시험표준 적용 타당성 연구 (A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter)

  • 김석곤;박창호;신동열;송태승;최용성
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1261-1267
    • /
    • 2011
  • Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.

다공성 표면 화염의 복사열효율측정에 관한 논의 (A Discussion on the Radiation Efficiency Measurement of Porous Surface Flames)

  • 정황희;심근선;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.157-159
    • /
    • 2014
  • This article describes an investigation of basic combustion characteristics of radiant burner with various firing rate and equivalence ratios in porous metal. As a main experimental condition, firing rates and equivalence ratios each were adjusted from 204 to $408kW/m^2$ and 0.6 to 1.3. The purpose of this study is to investigate radiation efficiency using two experiment methods. The first way is to calculate the radiation efficiency by measuring the temperature of the burner surface, and the second is to compute the radiation efficiency by measuring the radiation intensity of the burner surface with a radio meter. The value of the radiation efficiency did not exactly match in the two cases. But we figured out that in accordance with increasing heat power, radiation efficiency was decreased. And additional complementary experiment on the relationship between these values is needed.

  • PDF

HOW TO MONITOR AGN INTRA-DAY VARIABILITY AT 230GHZ

  • Kim, Jae-Young;Trippe, Sascha
    • 천문학회지
    • /
    • 제46권2호
    • /
    • pp.65-74
    • /
    • 2013
  • We probe the feasibility of high-frequency radio observations of very rapid flux variations in compact active galactic nuclei (AGN). Our study assumes observations at 230GHz with a small 6-meter class observatory, using the SNU Radio Astronomical Observatory (SRAO) as an example. We find that 33 radio-bright sources are observable with signal-to-noise ratios larger than ten. We derive statistical detection limits via exhaustive Monte Carlo simulations assuming (a) periodic, and (b) episodic flaring flux variations on time-scales as small as tens of minutes. We conclude that a wide range of flux variations is observable. This makes high-frequency radio observations-even with small observatories-a powerful probe of AGN intra-day variability; especially, those which complement observations at lower radio frequencies with larger observatories like the Korean VLBI Network (KVN).

HOW TO MONITOR AGN INTRA-DAY VARIABILITY AT 230 GHZ

  • 김재영
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.44.2-44.2
    • /
    • 2013
  • We probe the feasibility of high-frequency radio observations of very rapid flux variations in compact active galactic nuclei (AGN). Our study assumes observations at 230 GHz with a small 6-meter class observatory, using the SNU Radio Astronomical Observatory (SRAO) as example. We find that 33 radio-bright sources are observable with signal-to-noise ratios larger than ten. We derive statistical detection limits via exhaustive Monte Carlo simulations assuming (a) periodic, and (b) episodic flaring flux variations on time-scales as small as tens of minutes. We conclude that a wide range of flux variations is observable. This makes high-frequency radio observations - even with small observatories - a powerful probe of AGN intra-day variability; especially, those observations complement observations at lower radio frequencies with larger observatories like the Korean VLBI Network (KVN).

  • PDF

서울전파천문대(SRAO) 6M 망원경의 ON-THE-FLY 관측 시스템 구축 (DEVELOPMENT OF ON-THE-FLY(OTF) OBSERVATION METHOD FOR SEOUL RADIO ASTRONOMY OBSERVATORY(SRAO) 6-METER TELESCOPE)

  • 강현우;변도영;박용선
    • 천문학논총
    • /
    • 제20권1호
    • /
    • pp.73-83
    • /
    • 2005
  • On-The-Fly (OTF) observation method is developed for the efficient use of 6 M radio telescope at Seoul Radio Astronomy Observatory (SRAO). This technique, in which data and information of antenna position are recorded synchronously while driving a telescope regularly and rapidly across a field, provides more efficient use of telescope time and better calibration of the acquired data than the traditional point-to-point observation method does. For the realization of the method, we (1) added RT-Linux modules to the existing operating system, (2) replaced digital voltmeter with voltage-to-frequency converter, and (3) modified many SRAO observation programs. By observing Moon and G78.2+2.7 using this method and comparing them with previous observations, we verify the successful operation and efficiency of the OTF observation mode.