• Title/Summary/Keyword: Radiation technologies

Search Result 189, Processing Time 0.022 seconds

The Status and Prospects of Accelerators in Radiation Industries (방사선 산업용 가속기의 현황과 전망)

  • Chai, Jong-Seo
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.101-110
    • /
    • 2012
  • This paper is described the review of several selected accelerators and the use of accelerators in various purposes. The electrostatic accelerators and RF accelerators have been developed before the second world war for the purpose of basic research of physics mainly. RF driven accelerators have been achieved higher energy and applied in medical and industrial use after 1980's. Accelerators have improved incorporating new technologies : axial and horizontal injection, stripping extraction, superconducting RF, computer control, superconducting magnet etc.. Also recent key technologies as BT and NT make the expansion of applications of the accelerators.

Study of the Effect of (U0.8Pu0.2)O2 Uranium-Plutonium Mixed Fuel Fission Products on a Living Organism

  • Baimukhanova, Ayagoz;Kim, Dmitriy;Zhumagulova, Roza;Tazhigulova, Bibinur;Zharaspayeva, Gulzhanar;Azhiyeva, Galiya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.965-974
    • /
    • 2016
  • The article describes the results of experiments conducted on pigs to determine the effect of plutonium, which is the most radiotoxic and highly active element in the range of mixed fuel $(U_{0.8}Pu_{0.2})O_2$ fission products, on living organisms. The results will allow empirical prediction of the emergency plutonium radiation dose for various organs and tissues of humans in case of an accident in a reactor running on mixed fuel $(U_{0.8}Pu_{0.2})O_2$.

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

Preliminary Assessment of Radiation Impact from Dry Storage Facilities for PWR Spent Fuel (경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가)

  • Kim, T.M.;Baeg, C.Y.;Cha, G.Y.;Lee, W.G.;Kim, S.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.197-201
    • /
    • 2012
  • Annual dose at the boundary of the interim storage facility at normal condition was calculated to estimate the site area of the facility of PWR spent nuclear fuel. In this work, source term was generated by ORIGEN-ARP for 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facilities and radiation shielding evaluations were conducted by MCNP code depending on the storage capacity. In the case of the centralized storage system, the required site area was found to have the radius of more than 700 m.

Provision of a Draft Version for Standard Classification Structure for Information of Radiation Technologies through Analyzing Their Information and Derivation of Its Applicable Requirements to the Information System (방사선 기술정보 분석을 통한 정보표준분류체계(안) 마련 및 시스템 적용요건 도출)

  • Jang, Sol-Ah;Kim, Joo Yeon;Yoo, Ji Yup;Shin, Woo Ho;Park, Tai Jin;Song, Myung-jae
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • Radiation technology is the one for developing new products or processes by applying radiation or for creating new functions in industry, research and medical fields, and its application is increasing consistently. For securing an advanced technology competitiveness, it is required to create a new added value by information consumer through providing an efficient system for supporting information, which is the infrastructure for research and development, contributed to its collection, analysis and use with a rapidity and structure in addition to some direct research and development. Provision of the management structure for information resources is especially crucial for efficient operating the system for supporting information in radiation technology, and then a standard classification structure of information must be first developed as the system for supporting information will be constructed. The standard classification structure has been analyzed by reviewing the definition of information resources in radiation technology, and those classification structures in similar systems operated by institute in radiation and other scientific fields. And, a draft version of the standard classification structure has been then provided as 7 large, 25 medium and 71 small classifications, respectively. The standard classification structure in radiation technology will be developed in 2015 through reviewing this draft version and experts' opinion. Finally, developed classification structure will be applied to the system for supporting information by considering the plan for constructing this system and database, and requirements for designing the system. Furthermore, this structure will be designed in the system for searching information by working to the individual need of information consumers.

Fast Evaluation of Sound Radiation by Vibrating Structures with ACIRAN/AR

  • Migeot, Jean-Louis;Lielens, Gregory;Coyette, Jean-Pierre
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.561-562
    • /
    • 2008
  • The numerical analysis of sound radiation by vibrating structure is a well known and mature technology used in many industries. Accurate methods based on the boundary or finite element method have been successfully developed over the last two decades and are now available in standard CAE tools. These methods are however known to require significant computational resources which, furthermore, very quickly increase with the frequency of interest. The low speed of most current methods is a main obstacle for a systematic use of acoustic CAE in industrial design processes. In this paper we are going to present a set of innovative techniques that significantly speed-up the calculation of acoustic radiation indicators (acoustic pressure, velocity, intensity and power; contribution vectors). The modeling is based on the well known combination of finite elements and infinite elements but also combines the following ingredients to obtain a very high performance: o a multi-frontal massively parallel sparse direct solver; o a multi-frequency solver based on the Krylov method; o the use of pellicular acoustic modes as a vector basis for representing acoustic excitations; o the numerical evaluation of Green functions related to the specific geometry of the problem under investigation. All these ingredients are embedded in the ACTRAN/AR CAE tool which provides unprecedented performance for acoustic radiation analysis. The method will be demonstrated on several applications taken from various industries.

  • PDF

Ultrahigh Vacuum Technologies Developed for a Large Aluminum Accelerator Vacuum System

  • Hsiung, G.Y.;Chang, C.C.;Yang, Y.C.;Chang, C.H.;Hsueh, H.P.;Hsu, S.N.;Chen, J.R.
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.309-316
    • /
    • 2014
  • A large particle accelerator requires an ultrahigh vacuum (UHV) system of average pressure under $1{\times}10^{-7}$ Pa for mitigating the impact of beam scattering from the residual gas molecules. The surface inside the beam ducts should be controlled with an extremely low thermal outgassing rate under $1{\times}10^{-9}Pa{\cdot}m^3/(s{\cdot}m^2)$ for the sake of the insufficient pumping speed. To fulfil the requirements, the aluminum alloys were adopted as the materials of the beam ducts for large accelerator that thanks to the good features of higher thermal conductivity, non-radioactivity, non-magnetism, precise machining capability, et al. To put the aluminum into the large accelerator vacuum systems, several key technologies have been developed will be introduced. The concepts contain the precise computer numerical control (CNC) machining process for the large aluminum ducts and parts in pure alcohol and in an oil-free environment, surface cleaning with ozonized water, stringent welding process control manually or automatically to form a large sector of aluminum ducts, ex-situ baking process to reach UHV and sealed for transportation and installation, UHV pumping with the sputtering ion pumps and the non-evaporable getters (NEG), et al. The developed UHV technologies have been applied to the 3 GeV Taiwan Photon Source (TPS) and revealed good results as the expectation. The problems of leakage encountered during the assembling were most associated with the vacuum baking which result in the consequent trouble shootings and more times of baking. Then the installation of the well-sealed UHV systems is recommended.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

A Study on Evaluation Criteria and Procedures for Measuring Radiation Leakage of Aviation Security Equipment (항공보안장비 방사선 누출량 측정을 위한 평가 기준 및 절차에 관한 연구)

  • Kihyun Kim;Ye-Eun Jeong;Ye-Jun Kim;Yong Soo Kim
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.435-444
    • /
    • 2023
  • Purpose: To attain advanced performance certification, safety aspects along with functionality and performance are essential. Hence, this study suggests radiation leakage assessment methods for aviation security equipment during its performance certification. Methods: Detection technology guided the choice of radiation leakage assessment targets. We then detailed measurement and evaluation methods based on equipment type and operation mode. Equipment was categorized as container or box types for establishing measurement procedures. Results: We've developed specific radiation leakage assessment procedures for different types of aviation security equipment, crucial for ensuring airport safety. Using these procedures allows efficient evaluation of compliance with radiation leakage standards. Conclusion: The suggested radiation leakage assessment method aims to enhance aviation security and reliability. Future research will focus on identifying risks in novel aviation security equipment detection technologies and establishing safety standards.

Carbon Ion Therapy: A Review of an Advanced Technology

  • Kim, Jung-in;Park, Jong Min;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.71-80
    • /
    • 2020
  • This paper provides a brief review of the advanced technologies for carbon ion radiotherapy (CIRT), with a focus on current developments. Compared to photon beam therapy, treatment using heavy ions, especially a carbon beam, has potential advantages due to its physical and biological properties. Carbon ion beams with high linear energy transfer demonstrate high relative biological effectiveness in cell killing, particularly at the Bragg peak. With these unique properties, CIRT allows for accurate targeting and dose escalation for tumors with better sparing of adjacent normal tissues. Recently, the available CIRT technologies included fast pencil beam scanning, superconducting rotating gantry, respiratory motion management, and accurate beam modeling for the treatment planning system. These techniques provide precise treatment, operational efficiency, and patient comfort. Currently, there are 12 CIRT facilities worldwide; with technological improvements, they continue to grow in number. Ongoing technological developments include the use of multiple ion beams, effective beam delivery, accurate biological modeling, and downsizing the facility.