• Title/Summary/Keyword: Radiation quality

Search Result 1,600, Processing Time 0.034 seconds

Development of Freeze-dried Bibimbap, Korean Cooked Rice with Red Pepper Paste, as a Space Food Sterilized by Irradiation (동결건조 비빔밥을 이용한 방사선 멸균 우주식품 개발)

  • Lee, Ju-Yeon;Song, Beom-Seok;Park, Jae-Nam;Kim, Jae-Hun;Choi, Jong-Il;Park, Jong-Heum;Kim, Jae-Kyung;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.267-272
    • /
    • 2011
  • This study evaluated the microbial population (total aerobic count, fungi) and organoleptic quality of freeze-dried bibimbap sterilized by gamma irradiation to develop the space food. An irradiation dose above 30 kGy was needed to sterilize the freeze-dried bibimbap, while organoleptic quality of the sample was significantly decreased by irradiation (p<0.05). However, it was observed that scores on overall acceptance of rehydrated bibimbap after irradiation were the highest, when vitamin C and paprika extract were added at 0.1%, respectively. Therefore, it was considered that the freeze-dried bibimbap could be developed as a space food, which meet microbial requirements and organoleptic quality through addition of vitamin C 0.1% and paprika extract 0.1% before gamma irradiation at 30 kGy.

Development of Zygotic Embryos and Seedlings is Affected by Radiation Spectral Compositions from Light Emitting Diode (LED) System in Chestnut (Castanea crenata S. et Z.)

  • Park, So-Young;Kim, Man-Jo
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.5
    • /
    • pp.750-754
    • /
    • 2010
  • Among the environmental conditions employed in micropropagation, light quality plays an important role in growth, specially morphogenesis and photosynthesis. The effect of radiation quality (350-740 nm) on the development and growth of zygotic embryos and in vitro plantlets of open-pollinated chestnut (Castanea crenata S. et Z.) were studied. Two types of explants were exposed for 4 weeks to cool white (W, as control), monochromatic red (R, peak emission 650 nm), monochromatic blue (B, peak emission 440 nm), red+blue (R+B, 1:1), or red+far-red (R+Fr, 1:1, far-red peak emission 720 nm) radiation from a light-emitting-diode (LED) system. While the zygotic embryos showed positive photoblastic behavior, their germination was inhibited by blue radiation. Hypocotyl elongation and root development were promoted by red radiation. The emergence of primary leaf and its expansion were faster under blue than under red radiation. In the plantlets, red and red+far-red radiation significantly increased the formation and growth of the root, whereas blue light reduced rooting. Therefore, radiation quality appears to influence some steps in the development of zygotic embryos and plantlets in the chestnut.

Reducing frame rate and pulse rate for routine diagnostic cerebral angiography: ALARA principles in practice

  • Arvin R. Wali;Sarath Pathuri;Michael G. Brandel;Ryan W. Sindewald;Brian R. Hirshman;Javier A. Bravo;Jeffrey A. Steinberg;Scott E. Olson;Jeffrey S. Pannell;Alexander Khalessi;David Santiago-Dieppa
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.1
    • /
    • pp.46-50
    • /
    • 2024
  • Objective: Diagnostic cerebral angiograms (DCAs) are widely used in neurosurgery due to their high sensitivity and specificity to diagnose and characterize pathology using ionizing radiation. Eliminating unnecessary radiation is critical to reduce risk to patients, providers, and health care staff. We investigated if reducing pulse and frame rates during routine DCAs would decrease radiation burden without compromising image quality. Methods: We performed a retrospective review of prospectively acquired data after implementing a quality improvement protocol in which pulse rate and frame rate were reduced from 15 p/s to 7.5 p/s and 7.5 f/s to 4.0 f/s respectively. Radiation doses and exposures were calculated. Two endovascular neurosurgeons reviewed randomly selected angiograms of both doses and blindly assessed their quality. Results: A total of 40 consecutive angiograms were retrospectively analyzed, 20 prior to the protocol change and 20 after. After the intervention, radiation dose, radiation per run, total exposure, and exposure per run were all significantly decreased even after adjustment for BMI (all p<0.05). On multivariable analysis, we identified a 46% decrease in total radiation dose and 39% decrease in exposure without compromising image quality or procedure time. Conclusions: We demonstrated that for routine DCAs, pulse rate of 7.5 with a frame rate of 4.0 is sufficient to obtain diagnostic information without compromising image quality or elongating procedure time. In the interest of patient, provider, and health care staff safety, we strongly encourage all interventionalists to be cognizant of radiation usage to avoid unnecessary radiation exposure and consequential health risks.

Forage Quality Evaluation of Mutant Lines derived from Gamma-ray Treatments in Rubus fructicosus L. (감마선 조사 유래 블랙베리(Rubus fructicosus L.) 돌연변이 계통의 농업부산물 사료가치 분석)

  • Ryu, Jaihyunk;Kim, Dong sub;Ha, Bo-Keun;Kim, Jin-Baek;Kim, Sang Hoon;Ahn, Joon-Woo;Jeong, Il Yun;Jo, Han-Jik;Kim, Ee-Yup;Kang, Si-Yong
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • We examined the forage quality to provide the basic information for the utilization of blackberry by-products (leaf and stem) among thirty-five mutant lines derived from gamma-ray. The leaves had higher crude protein (CP) contents than stems. In addition, the leaves showed broad ranges of variation in crude fat, crude fiber and crude ash. The overall forage quality of the stems were similar to those of the original variety. The mean of neutral detergent fiber (NDF) content of leaves and stems in mutant lines were 25.88% and 58.98%, respectively. Also, the mean of acid detergent fiber (ADF) content of leaves and stems in mutant lines were 15.43% and 49.27%, respectively. Forage quality grades of all blackberry leaf were special quality class. However, the blackberry stem ranked $1^{st}$ to $5^{th}$ in quality class. The stem diameter was negatively ($P{\leq}0.05$) correlated with the moisture and crude protein. Also, the fruit length was highly negatively ($P{\leq}0.01$) correlated with the RFV (relative feed value) in blackberry leaf. The one hundred fruit weight was highly negatively ($P{\leq}0.01$) correlated with the crude ash. Based on these results, the by-products of blackberry could provide high quality forage for feeding of live stock.

Solar Radiation Measurement and Data Quality Management (태양자원 측정 및 데이터 품질관리)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.63.2-63.2
    • /
    • 2010
  • Solar radiation data are used in several forms and for a variety of purposes. The most detailed information we have is beam and diffuse solar radiation on a horizontal surface, by hours, which is useful in simulations of solar processes. Daily data are more often available and monthly total solar radiation on horizontal surface can be used in some process design methods. However, as performance is generally not linear with solar radiation, the use of average may lead to serious errors if non-linearities ara not taken into account. It is also possible to reduce radiation data to more manageable forms by statistical methods. The control of the quality of most measurements is relegated to the control of the measuring instruments and measuring processes themselves. An accurate measurement will usually result from the use of a high-quality instrument that has been accurately calibrated and is properly used by a qualified individual.

  • PDF

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Effects of Irradiation Temperature on the Sensory Quality Improvement of Gamma-irradiated Ganjang-gejang, Korean Traditional Marinated Raw Crab Portunus trituberculatus in Soybean Sauce

  • Park, Jae-Nam;Byun, Eui-Baek;Han, In-Jun;Song, Beom-Seok;Sohn, Hee-Sook;Park, Sang-Hyun;Byun, Eui-Hong;Yoon, Minchul;Sung, Nak-Yun
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • This study was conducted to confirm quality properties of sterilized Ganjang-gejang (marinated crab Portunus trituberculatus) with Korean soy sauce using by gamma irradiation and to improve quality of sterilized Ganjang-gejang. The Ganjang-gejang was irradiated at dose of 3, 6, 9, 12, and 15 kGy by gamma irradiation and there was evaluated in microbiological, physicochemical, and sensory properties. Total aerobic bacteria and fungi contents of non-irradiated samples were about 6 and 4 log CFU/g level, respectively. Gamma-irradiated samples at above 9 kGy did not contain aerobic bacteria or fungi at detection limit less than 2 log CFU/g, but sensory scores were significantly decreased depending on the irradiation dose. To improve the sensory qualities of gamma-irradiated Ganjang-gejang, the temperature was adjusted during sample irradiation. When samples were irradiated under freezing temperatures, especially on dry ice, the TBARS and the deterioration of sensory qualities of Ganjan-Gejang were reduced. Different odor patterns were observed among samples, as observed using electronic nose analysis system. The results of this study indicated that treatment with irradiation under low temperatures may help to preparing high-quality Ganjang-gejang.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Effect of Choi-cha on Fermentation Characteristics and Sensory Quality of Chungkookjang (Korean Fermented Soybean) (초의차 첨가가 청국장의 발효특성과 관능적 품질에 미치는 영향)

  • Lee, Hyun-Joo;Kim, Sun-Im;Park, Jin-Gyu;Park, Jae-Nam;Han, In-Jun;Song, Beom-Seok;Kim, Jae-Hun;Byun, Myung-Woo;Lee, Ju-Woon
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.144-149
    • /
    • 2008
  • Physiological, sensory and microbiological evaluations were conducted during fermentation of Chungkookjang. with Choi-cha (non-fermented green tea) powder in efforts to improve the sensory quality of Chungkookjang. Growth of fermentative microorganisms in Chungkookjang was inhibited by Choi-cha; the pH and VBN value decreased as the concentration of Choi-cha increased. Brightness (L) and redness (a) of Chungkookjang fermented with Choi-cha were significantly decreased, resulting in the appearance of all samples fermented with Choi-cha being less attractive than was the control. The sensory quality of Chungkookjang was significantly increased when Choi-cha was added up to 3%, (w/v), and off-odor was reduced. The antioxidative property of Chungkookjang fermented with 3% (w/v) Choi-cha was significantly higher than that of the control. This result indicated that the sensory quality of Chungkookjang was improved by fermentation with 3% (w/v) of Choi-cha powder.

Development of Novalis Quality Assurance Protocol for Radiosurgery (방사선수술을 위한 노발리스 품질관리 프로토콜 개발)

  • Lee, Dong-Joon;Lee, Kyung-Nam;Lee, Suk;Lee, Sang-Hoon;Kim, Dae-Hong
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.99-112
    • /
    • 2010
  • In Republic of Korea, there are many Quality Assurance protocol for general radiation treatment machine such as linac. However, Quality Assurance protocol for radiosurgery treatment system is not ready perfectly. One of the radiation treatment machine for radiosurgery, novalis system needs to suitable Quality Assurance protocol for using it right way during radiation treatment and maintaining suitable accuracy for daily, weekly, monthly and annually periods. Therefore, in this article, we develop Quality Assurance protocol for novalis system. We collected and analysed domestic and foreign novalis Quality Assurance protocol. After that, we selected essential QA items and each tolerance range for developing proper QA protocol, and we made anatomical phantom for execution of selected QA items and evaluation of overall state of QA, and then, we use this measured value as a reference. Quality Assurance items are consisted of Mechanical accuracy QA part and Radiation delivery QA part. Mechanical accuracy QA part is comprised of radiation generation machine part, assistive devices part and multi-leaf collimator part. Radiation delivery QA part is divided into radiation isocenter accuracy and dosimetric evaluation. After that, developed novalis QA tables are made by using these QA items. These novalis QA tables would be used to good standard in order to maintain apt accuracy for radiosurgery in daily, weekly, monthly and annually periods.