• Title/Summary/Keyword: Radiation pattern measurement

Search Result 121, Processing Time 0.027 seconds

Manufacturing and Characterization of N-doped TiO2 Photocatalytic Thin Film (N 도핑된 TiO2 광촉매 박막의 제조 및 특성분석)

  • Park, Sang-Won;Nam, Soo-Kyung;Heo, Jae-Eun
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.683-688
    • /
    • 2007
  • In this study, N doped $TiO_2$ (TiO-N) thin film was prepared by DC magnetron sputtering method to show the photocatalytic activity in a visible range. Various gases (Ar, $O_2\;and\;N_2$) were used and Ti target was impressed by 1.2 kW -5.8 kW power range. The hysteresis of TiO-N thin film as a function of discharge voltage wasn't observed in 1.2 and 2.9kW of applied power. Cross sections and surfaces of thin films by FE-SEM were tiny and dense particle sizes of both films with normal cylindrical structures. XRD pattern of $TiO_2$ and TiO-N thin films was appeared by only anatase peak. Red shift in UV-Vis adsorption spectra was investigated TiO-N thin film. Photoactivity was evaluated by removal rate measurement of suncion yellow among reactive dyes. The photodegradation rate of $TiO_2$ thin film on visible radiation was shown little efficiency but TiO-N was about 18%.

A Wide Band Antenna Design using the Synthesis of Independent Dual Resonance Modes for Manpack SDR(Software Defined Radio) (독립적인 이중 공진 모드 합성을 이용한 광대역 SDR 무전기 안테나 설계)

  • Yu, Byunggil;Dong, Moo-Ho;Cho, Ji-Haeng;Han, Sung-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper, we have proposed a wide band antenna for manpack SDR(Software Defined Radio). The proposed antenna consists of feeding post, flexible gooseneck and two radiating elements composed of a upper and lower radiators. The upper radiator has a longer electrical length than the lower radiator in order to operate in the lower frequency. Also, the resonant frequency and impedance characteristics of the antenna can be adjusted independently for two radiators. Therefore, the proposed antenna can be achieved wide impedance bandwidth by the combination of two independent resonance modes. To analyze the characteristics of the antenna in the design process is employed the equivalent circuit theory and EM(Electro-Magnetic) simulation. The measurement results show that the proposed antenna have the sufficient wide bandwidth, above -3.4dBi of the gain and fairly good radiation pattern over the wide bandwidth.

Dualband Shared-Aperture Microstrip Antenna for Reflectarray Feeding Structure of LEO Satellite System

  • Bagas Satriyotomo;Ji-Woong Hyun;Seongmin Pyo
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.20-25
    • /
    • 2024
  • This paper presents a new dualband shared-aperture microstrip antenna to operate in the S-Band of 2 GHz and X-Band of 8 GHz, for a Low Earth Orbit satellite antenna system. The proposed antenna incorporates two types of patches those are a rectangular loop-shaped for the S-Band and a square patch for the X-Band. Each patch are optimized for its respective operating band with minimal interference. The proposed antenna achieves a bandwidth of 16 MHz in the S-Band and 572 MHz in the X-Band. The highest gain is measured 7.14 dBi at 1.99 GHz and 7.95 dBi at 7.88 GHz. The proposed antenna exhibits half power beamwidths of 85 degree and 80 degree at 1.99 GHz and 7.88 GHz, respectively. The proposed dualband shared-aperture microstrip antenna may be a good candidate for as a feeding system of a dualband reflectarray antenna With its unidirectional radiation pattern from excellent agreement between simulation and measurement results.

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.

Fabrication and Measurement of Triple U-shaped slot Microstrip Antenna in 5GHz band (5GHz 대역에서 트리플 U-슬롯 모양의 마이크로스트립 안테나 설계 및 제작)

  • Kang, Moon-Kyou;Jung, Yoo-Keun;Ju, Jeong-Min;Jeong, Gyey-Teak;Yoon, Joong-Han;Kwak, Kyung-Sup
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.86-95
    • /
    • 2004
  • In this paper, we designed, fabricated, and measured antenna results consisting of previous research, that can handle from wireless using-LAN U-shaped slot antenna of HiperLAN bandwidth to ISM band of HiperLAN 1/2 & 5 GHz bandwidth. We presented a new model that structuresof basic U-shaped slot added the same thing twice.After the foam layer is inserted between ground plane and substrate, we got enough bandwidth for VSWR<1.5. The antenna gain was $6.27{\sim}9.82dBi$. The radiation pattern got a stable pattern in frequency bandwidth.

  • PDF

Design of Rectangular Planar Monopole Antenna with a Double Sleeve (이중 슬리브를 갖는 직사각형 평면 모노폴 안테나 설계)

  • Kang, Sang-Won;Chang, Tae-Soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.215-220
    • /
    • 2016
  • In this paper, a wideband antenna accomplished by adding a double sleeve of a rectangular planar monopole structure is proposed. In order to impedance matching of proposed antenna, the antenna performance was improved by adding two gap sleeves and outer sleeve for double sleeve structure. HFSS simulator of ANSYS corp. was used in order to confirm the antenna parameter characteristic. According to the simulation results, the VSWR was less than 2 for the range of 2.5GHz~10.5GHz. The frequency bandwidth is 8GHz. The frequency range of the actual fabricated antenna was 2.92GHz~10.32GHz, the frequency bandwidth is 7.4GHz. The measured radiation pattern frequency is 3GHz, 6GHz and 9GHz. The results are similar with dipole antenna pattern in all frequency. The antenna size is $40{\times}40mm^2$. The utilization possibility of the ultra-wideband planar monopole antenna could be confirmed according to compare and analyze the simulation and measurement data.

The Measurement and Consideration of Path Loss in Domestic Terrain Environments for IMT-2000 (국내지형환경에서의 IMT-2000주파수 대 경로손실 측정 및 고찰)

  • 이상수;이동진;최학근;김준철;박원진
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.12
    • /
    • pp.547-552
    • /
    • 2002
  • In this paper, the path loss in domestic terrain environments for IMT-2000 are measured and considered. Domestic terrain environments are classified and received power is measured at 1.9201GHz. In addition, the Path loss is calculated with consideration of the radiation pattern of antennas based on the results of measurement. For the consideration of path loss in domestic terrain environments, each path loss are fitted with the same slope of a reference model as "COST-231 HATA Urban Model", and then both are compared. As a result, all of the path loss in domestic terrain environments are lower than the path loss of a reference model as "COST-231 HATA Urban Model". We found that a difference of path loss in domestic terrain environments and a reference model is 5dB in urban, 8dB in sparse urban, 12dll in dense suburban, 13dB in suburban, 19dB in sparse suburban, and 29dB in road.

A Compact CPW-fed Antenna with Two Slit Structure for WLAN/WiMAX Operations (WLAN/WiMAX 대역에서 동작하는 두 개의 슬릿 구조를 갖는 CPW 급전방식 소형 안테나)

  • Kim, Woo-Su;Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.759-766
    • /
    • 2022
  • In this paper, we propose a multi-band small antenna with CPW(Coplanar Waveguide) feeding structure WLAN(Wireless Local Area Network) and WiMAX (Worldwide Interoperability for Microwave Access) bands. The proposed antenna is designed two slit in the modified monopole type radiator and FR-4 substrate, which is thickness 1.0 mm, and the dielectric constant is 4.4. The size of proposed antenna is 15.1 mm⨯16.41 mm, and total size of proposed antenna is 17.5 mm⨯16.4 mm. From the fabrication and measurement results, From the fabrication and measurement results, bandwidths of 439 MHz (2.06 to 2.499 GHz), 840 MHz (3.31 to 4.25) and 1,315 MHz (5.23 to 6.545 GHz) were obtained on the basis of -10 dB impedance bandwidth. Also, 3D radiation pattern characteristics of the proposed antenna are displayed and measured gains 2.24 dBi, 2.83 dBi, and 2.0 dBi shown in the three frequency band, respectively.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF