• Title/Summary/Keyword: Radiation oncology practice

Search Result 78, Processing Time 0.027 seconds

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

History of Radiation Therapy Technology

  • Huh, Hyun Do;Kim, Seonghoon
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.124-134
    • /
    • 2020
  • Here we review the evolutionary history of radiation therapy technology through the festschrift of articles in celebration of the 30th anniversary of Korean Society of Medical Physics (KSMP). Radiation therapy technology used in clinical practice has evolved over a long period of time. Various areas of science, such as medical physics, mechanical engineering, and computer engineering, have contributed to the continual development of new devices and techniques. The scope of this review was restricted to two areas; i.e., output energy production and functional development, because it is not possible to include all development processes of this technology due to space limitations. The former includes the technological transition process from the initial technique applied to the first model to the latest technique currently used in a variety of machines. The latter has had a direct effect on treatment outcomes and safety, which changed the paradigm of radiation therapy, leading to new guidelines on dose prescriptions, innovation of dose verification tools, new measurement methods and calculation systems for radiation doses, changes in the criteria for errors, and medical law changes in all countries. Various complex developments are covered in this review. To the best of our knowledge, there have been few reviews on this topic and we consider it very meaningful to provide a review in the festschrift in celebration of the 30th anniversary of the KSMP.

An Accidental over Exposure in Mednif Tele-Cobalt Machine in Nepal

  • chaurasia, P.P.;Srivastava, R.P.;Prasiko, G.;Neupane, B.P.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.97-99
    • /
    • 2002
  • A radiation incident took place during treatment on MEDNIF Tele cobalt-60 therapy machine in B.P.KOIRALA MEMORIAL CANCER HOSPITAL in Bharatpur, Nepal. This Chinese made machine has activity of 6240 Curies of cobalt -60. This machine has fulfilled safety requirements. ICRP recommendations, safety rules are followed and practiced. The source was struck up during treatment and a technician was exposed to equivalent dose of 13.75 mSv. recorded by Personal film badge. Risks of workers are comparable to other safe industries. All exposures shall be kept as low as reasonably possible. The higher level of safety is achieved only when every one is dedicated to common goal. A lesson is learnt for future. Good practice is essential but not sufficient. A high demand for tele Cobalt therapy convinced management to replace Mednif machine with a new efficient Elite Tele Cobalt theratron Machine.

  • PDF

2022 KLCA-NCC Korea Practice Guidelines for the Management of Hepatocellular Carcinoma

  • Korean Liver Cancer Association (KLCA) and National Cancer Center (NCC) Korea
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1126-1240
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and the fourth most common cancer among men in South Korea, where the prevalence of chronic hepatitis B infection is high in middle and old age. The current practice guidelines will provide useful and sensible advice for the clinical management of patients with HCC. A total of 49 experts in the fields of hepatology, oncology, surgery, radiology, and radiation oncology from the Korean Liver Cancer Association-National Cancer Center Korea Practice Guideline Revision Committee revised the 2018 Korean guidelines and developed new recommendations that integrate the most up-to-date research findings and expert opinions. These guidelines provide useful information and direction for all clinicians, trainees, and researchers in the diagnosis and treatment of HCC.

A Review of Korean Medicine for Clinical Practice Guidelines for Cervical Cancer (자궁경부암의 한의학적 진료에 대한 고찰)

  • Jung, Hyun-Jung;Yoo, Hwa-seung
    • Journal of Korean Traditional Oncology
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2016
  • The incidence rate of cervical cancer in Korea is still higher than in other developed countries, notwithstanding the national mass screening program. Cervical cancer prognosis is good due to an effective treatment such as surgery or radiation therapy, concurrent chemotherapy in the early stage. However, it is still a poor prognosis when advanced stage or recurrent. Some studies said that combined oriental and western medicine can improve the survival, quality of life, immune function, and decrease side effects in cervical cancer. In the western medical part, clinical practice guideline was published in 2006, 2007 and 2010 in Korea. In China, oriental medicine clinical practice guideline have been published in 2014. But there is no Korean medicine clinical practice guideline. This study will introduce the methods of diagnosis and the medical therapeutics which is commonly utilized for cervical cancer in Korea, and existing Korean medicine clinical practice guideline for Disease Analysis and Treatment (辨證論治). This study will be a meaningful study to establish clinical practice guidelines of Korean Medicine for cervical cancer.

Korean Practice Guidelines for Gastric Cancer 2022: An Evidence-based, Multidisciplinary Approach

  • Tae-Han Kim;In-Ho Kim;Seung Joo Kang;Miyoung Choi;Baek-Hui Kim;Bang Wool Eom;Bum Jun Kim;Byung-Hoon Min;Chang In Choi;Cheol Min Shin;Chung Hyun Tae;Chung sik Gong;Dong Jin Kim;Arthur Eung-Hyuck Cho;Eun Jeong Gong;Geum Jong Song;Hyeon-Su Im;Hye Seong Ahn;Hyun Lim;Hyung-Don Kim;Jae-Joon Kim;Jeong Il Yu;Jeong Won Lee;Ji Yeon Park;Jwa Hoon Kim;Kyoung Doo Song;Minkyu Jung;Mi Ran Jung;Sang-Yong Son;Shin-Hoo Park;Soo Jin Kim;Sung Hak Lee;Tae-Yong Kim;Woo Kyun Bae;Woong Sub Koom;Yeseob Jee;Yoo Min Kim;Yoonjin Kwak;Young Suk Park;Hye Sook Han;Su Youn Nam;Seong-Ho Kong;The Development Working Group for the Korean Practice Guidelines for Gastric Cancer 2022 Task Force Team
    • Journal of Gastric Cancer
    • /
    • v.23 no.1
    • /
    • pp.3-106
    • /
    • 2023
  • Gastric cancer is one of the most common cancers in Korea and the world. Since 2004, this is the 4th gastric cancer guideline published in Korea which is the revised version of previous evidence-based approach in 2018. Current guideline is a collaborative work of the interdisciplinary working group including experts in the field of gastric surgery, gastroenterology, endoscopy, medical oncology, abdominal radiology, pathology, nuclear medicine, radiation oncology and guideline development methodology. Total of 33 key questions were updated or proposed after a collaborative review by the working group and 40 statements were developed according to the systematic review using the MEDLINE, Embase, Cochrane Library and KoreaMed database. The level of evidence and the grading of recommendations were categorized according to the Grading of Recommendations, Assessment, Development and Evaluation proposition. Evidence level, benefit, harm, and clinical applicability was considered as the significant factors for recommendation. The working group reviewed recommendations and discussed for consensus. In the earlier part, general consideration discusses screening, diagnosis and staging of endoscopy, pathology, radiology, and nuclear medicine. Flowchart is depicted with statements which is supported by meta-analysis and references. Since clinical trial and systematic review was not suitable for postoperative oncologic and nutritional follow-up, working group agreed to conduct a nationwide survey investigating the clinical practice of all tertiary or general hospitals in Korea. The purpose of this survey was to provide baseline information on follow up. Herein we present a multidisciplinary-evidence based gastric cancer guideline.

Institutional Experience of Interstitial Brachytherapy for Head and Neck Cancer with a Comparison of High- and Low Dose Rate Practice

  • Mohanti, Bidhu Kalyan;Sahai, Puja;Thakar, Alok;Sikka, Kapil;Bhasker, Suman;Sharma, Atul;Sharma, Seema;Bahadur, Sudhir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.813-818
    • /
    • 2014
  • Aims: To describe our institutional experience with high dose rate (HDR) interstitial brachytherapy (IBT) compared with previously reported results on the low dose rate (LDR) practice for head and neck cancer. Materials and Methods: Eighty-four patients with oral cavity (n=70) or oropharyngeal cancer (n=14) were treated with 192Ir HDR-IBT. Seventy-eight patients had stage I or II tumour. The patients treated with IBT alone (n=42) received 39-42 Gy/10-14 fractions (median=40 Gy/10 fractions). With respect to the combination therapy group (n=42), prescription dose comprised of 12-18 Gy/3-6 fractions (median=15 Gy/5 fractions) for IBT and 40-50 Gy/20-25 fractions (median=50 Gy/25 fractions) for external radiotherapy. Brachytherapy was given as 2 fractions per day 6 hours apart with 4 Gy per fraction for monotherapy and 3 Gy per fraction for combination therapy. Results: Four patients were not evaluable in the analysis of outcome. The primary site relapse rates were 23.8% (10/42) and 68.4% (26/38) in patients treated with IBT alone and combination therapy, respectively (p<0.001). Salvage surgery was performed in 19 patients. The 5-year local control rate was estimated at 62% and the disease-free survival (DFS) rate at 52% for all patients. Local control with respect to T1 and T2 tumours was 84% and 42%, respectively. Conclusions: Our present series on HDR-IBT and the previous report on LDR-IBT for head and neck cancer demonstrated similar DFS rates at 5 years (52%). The rate of regional failure in node-negative patients was <20% in both of our series. HDR-IBT offers similar results to LDR-IBT for head and neck cancer.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh-Phantom to DICOM-RT Dataset

  • Se Hyung Lee;Bo-Wi Cheon;Chul Hee Min;Haegin Han;Chan Hyeong Kim;Min Cheol Han;Seonghoon Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.172-179
    • /
    • 2022
  • Recently, tetrahedral phantoms have been newly adopted as international standard mesh-type reference computational phantoms (MRCPs) by the International Commission on Radiological Protection, and a program has been developed to convert them to computational tomography images and DICOM-RT structure files for application of radiotherapy. Through this program, the use of the tetrahedral standard phantom has become available in clinical practice, but utilization has been difficult due to various library dependencies requiring a lot of time and effort for installation. To overcome this limitation, in this study a newly developed TET2DICOM-GUI, a TET2DICOM program based on a graphical user interface (GUI), was programmed using only the MATLAB language so that it can be used without additional library installation and configuration. The program runs in the same order as TET2DICOM and has been optimized to run on a personal computer in a GUI environment. A tetrahedron-based male international standard human phantom, MRCP-AM, was used to evaluate TET2DICOM-GUI. Conversion into a DICOM-RT dataset applicable in clinical practice in about one hour with a personal computer as a basis was confirmed. Also, the generated DICOM-RT dataset was confirmed to be effectively implemented in the radiotherapy planning system. The program developed in this study is expected to replace actual patient data in future studies.

Preliminary Study for Development of Korean Medicine Clinical Practice Guideline for Pancreatic Cancer (췌장암 한의 임상진료지침 개발 예비 연구)

  • Park, Soo-Jung;Yoo, Hwa-Seung;Yu, Jun-Sang
    • Journal of Korean Traditional Oncology
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate preliminarily for development of the Korean medicine clinical practice guideline (CPG) for pancreatic cancer through the analysis of existing CPGs. Methods: Through searching the medical database such as Pubmed, SCOPUS, CNKI, Google Scholar, etc. The global CPGs within recent three years were collected and analyzed. In particular, recommendations related to the Korean medicine or Chinese medicine were made primarily in the Guidelines of Diagnosis and Therapy in Oncology with Traditional Chinese Medicine. Results: The six CPGs were mentioned in this study. The academic societies and organizations developing the CPGs were located in China, Japan, Europe and America. The contents of the CPGs were the clinical questions and statements, surgical therapy, adjuvant therapy, radiation therapy, chemotherapy, palliative medicine, risk assessment, palliation and supportive care, follow-up and recurrence, Tumor-Node-Metastasis (TNM) staging. In the Guidelines of Diagnosis and Therapy in Oncology with Traditional Chinese Medicine, the etiology, mechanisms, herbal drugs, Chinese medicine assessment, complication, syndrome differentiation (SD), Chinese medicine treatment were described. Conclusions: In order to develop the proper Korean medicine CPG for pancreatic cancer and to adapt the correct integrative treatment program on the pancreatic cancer, institutional arrangements for cooperation with Korean medical communities and standardization of SD should be performed.