• 제목/요약/키워드: Radiation map

검색결과 156건 처리시간 0.024초

건물과 수목의 그림자에 의한 도시의 열 분포 산정 및 저감효과 연구 (Estimating the urban radiation heat flux distribution and the reduction effect of building and tree shade)

  • 박채연;이동근;윤준하
    • 한국환경복원기술학회지
    • /
    • 제21권6호
    • /
    • pp.1-13
    • /
    • 2018
  • Mapping radiation heat flux of urban area is essential for urban design and landscape planning. Because controlling urban geometry and generating green space are important urban design strategies for reducing urban heat, urban planner and designer need to recognize the micro urban heat distribution for adequate urban planning. This study suggests a new methodology for mapping urban radiation heat flux in a micro scale considering buildings and trees' shade. For doing that, firstly, we calculate net radiation for each urban surfaces (building, road (not shaded, building shaded, tree shaded), ground (not shaded, building shaded, tree shaded), tree (not shaded, building shaded)). Then, by multiplying the area ratio of surfaces to the net radiation, we can obtain the radiation heat flux in micro-scale. The estimated net radiation results were found to be robust with a $R^2$ of 90%, which indicates a strong explanatory power of the model. The radiation heat flux map for 12h $17^{th}$ August explains that areas under the building and tree have lower net radiation heat flux, indicating that shading is a good strategy for reducing incident radiation. This method can be used for developing thermal friendly urban plan.

COASTAL ENVIRONMENT MONITORING USING ADJACENT EFFECT OF RADIATION

  • Takashima, Tsutomu;Jung, Sung-Chul;Yi, San-Oh;Kim, Tu-Hwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.430-431
    • /
    • 2006
  • KOMPSAT-2 was successively launched on July 28,06. She carries Fine Spatial Resolution Sensor with three channels. It is 4m monochromatic and 1m panchromatic. The main purposes would derive fine urban map and digital elevation model(DEM).Therefore we extend to coastal environment monitoring using the adjacent effect of radiation due to an interaction of radiation between heterogeneous surface and atmosphere. With data analysis of ASTER on TERA, which is 15m resolution in visible and near infrared wavelengths, we found atmospheric aerosols were always large. Note that data analysis was limited in Nagoya bay, Lake Tahoe, California & La Pozuelos, La Picasa, Argentina. Thus this time we expect data analyses around isolated island and peninsula in west and south coast of Korea.

  • PDF

라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가 (Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings)

  • 윤석원;김용재;장병욱;변종인;윤주용
    • Journal of Radiation Protection and Research
    • /
    • 제33권4호
    • /
    • pp.173-181
    • /
    • 2008
  • 실내 라돈 검출기의 신뢰성 평가를 위해서 미국 Landauer사의 $RadTrak^{(R)}$, 헝가리 Radosys사의 $Radopot^{(R)}$, 그리고 미국 Rad elec 사의 $E-PERM^{(R)}$ 검출기의 성능을 비교 검토하였다. RadTrak과 Radopot에 대한 라돈 표준 챔버 테스트 결과, $AlphaGUARD^{(R)}$ 검출 결과와 비교하여 각각 -13.2%. -6.0%로 라돈 검출기 성능평가기준인 ${\pm}20%$ 이내에 포함되는 결과를 보였다. 또한, 실제 현장에서의 장기간 측정을 통한 성능을 평가하기 위하여 약 100여개의 가옥 내 동일한 장소에 각각의 검출기를 1 년 동안 설치하여 비교하였다. RadTrak 과 Radopot 의 비교에서는 매우 좋은 상관관계 ($R^2$ = 0.91)를 보였지만, E-PERM과 Radopot의 비교결과, 거의 상관성을 파악 할 수 없었다($R^2$ = 0.021). 또한, E-PERM을 이용한 연평균 전국 실내 공간감마선량률 등준위도는 Portable Ion Chamber를 이용한 전국 실외 공간감마선량률 등준위도와 다소 상이한 결과를 보였다. 실험 결과를 바탕으로 향 후 대규모 라돈농도조사에 필요한 검출기 선정 요건에 대해서 논의 하였다.

Probing Cosmic Near Infrared Background using AKARI Data

  • 서현종;;정웅섭;이형목;;;;표정현
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.34.1-34.1
    • /
    • 2013
  • The first generation stars in the universe are not observed as discrete objects by using current observational facilities, but their contributions are redshifted to the near infrared wavelength bands at present universe. Therefore, investigation of background radiation at near infrared is important for the study of the first stars. In this study, we present new observations of spatial fluctuations in sky brightness toward the north ecliptic pole using data from AKARI. Among pointed observation program of AKARI, we used two pointing surveys named Monitor field and NEP wide field at three wavelength bands 2.4, 3.2, and 4.1 ${\mu}m$. To obtain spatial fluctuations from observed images, first of all, we exclude pixels affected by resolved foreground objects and then obtain diffuse map which consists of diffused radiation only. Because the diffuse map contains not only cosmological components but also various foreground components, in order to detect cosmological components, we estimate the contributions of foreground components separately. The results of this study show that there remains excess spatial fluctuation that cannot be explained by known foreground sources. This work is based on observations with AKARI, a JAXA project with the participation of ESA.

  • PDF

Probing Cosmic Near Infrared Background using AKARI Data

  • 서현종;;정웅섭;이형목;;;;표정현
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.35.1-35.1
    • /
    • 2013
  • The first generation stars in the universe are not observed as discrete objects by using current observational facilities, but their contributions are redshifted to the near infrared wavelength bands at present universe. Therefore, investigation of background radiation at near infrared is important for the study of the first stars. In this study, we present new observations of spatial fluctuations in sky brightness toward the north ecliptic pole using data from AKARI. Among pointed observation program of AKARI, we used two pointing surveys named Monitor field and NEP wide field at three wavelength bands 2.4, 3.2, and 4.1 ${\mu}$. To obtain spatial fluctuations from observed images, first of all, we exclude pixels affected by resolved foreground objects and then obtain diffuse map which consists of diffused radiation only. Because the diffuse map contains not only cosmological components but also various foreground components, in order to detect cosmological components, we estimate the contributions of foreground components separately. The results of this study show that there remains excess spatial fluctuation that cannot be explained by known foreground sources. This work is based on observations with AKARI, a JAXA project with the participation of ESA.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

국내 수처리시설 종사자 작업유형에 따른 외부피폭방사선량 평가 (Assessment of External Radiation Dose for Workers in Domestic Water Treatment Facility According to the Working Type)

  • 전성훈;이성연;김혁재;김민성;김광표
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.151-160
    • /
    • 2023
  • The International Atomic Energy Agency (IAEA) proposes 11 industries that handle Naturally Occurring Radioactive Material (NORM) that are considered to need management. A water treatment facility is one of the above industries that takes in groundwater and produces drinking water through a water treatment process. Groundwater can accumulate natural radionuclides such as uranium and thorium in raw water by contacting rocks or soil containing natural radionuclides. Therefore, there is a possibility that workers in water treatment facilities will be exposed due to the accumulation of natural radionuclides in the water treatment process. The goal of this study is to evaluate the external radiation dose according to the working type of workers in water treatment facilities. In order to achieve the above goal, the study was conducted by dividing it into 1) analysis of the exposure environment, 2) measurement of the external radiation dose rate 3) evaluation of the external radiation dose. In the stage of analyzing the exposure environment, major processes that are expected to occur significantly were derived. In the measurement stage of the external radiation dose rate, a map of the external radiation dose rate was prepared by measuring the spatial radiation dose rate in major processes. Through this, detailed measurement points were selected considering the movement of workers. In the external radiation dose evaluation stage, the external radiation dose was evaluated based on the previously derived external radiation dose rate and working time. As a result of measuring the external radiation dose rate at the detailed points of water treatment facilities A to C, it was 1.90×10-1 to 3.75×100 μSv h-1, and the external radiation dose was analyzed as 3.27×10-3 to 9.85×10-2 mSv y-1. The maximum external radiation dose appeared during the disinfection and cleaning of activated carbon at facility B, and it is judged that natural radionuclides were concentrated in activated carbon. It was found that the external radiation dose of workers in the water treatment facility was less than 1mSv y-1, which is about 10% of the dose limit for the public. As a result of this study, it was found that the radiological effect of external radiation dose of domestic water treatment facility workers was insignificant. The results are expected to contribute as background data to present optimized safety management measures for domestic NORM industries in the future.

임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발 (Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes)

  • 박지연;정원균;이정우;이경남;안국진;홍세미;주라형;최보영;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.153-164
    • /
    • 2010
  • 혈관분포도(vascularity) 및 세포조밀도(cellularity)와 같은 종양의 생물학적 특성을 고려한 임상표적체적을 결정하기 위하여, 국부혈류용적영상(regional cerebral blood volume map, rCBV map)과 겉보기확산계수영상(apparent diffusion coefficient map, ADC map)의 종양 체적을 해부학적 영상 위에 맵핑 할 수 있는 소프트웨어를 개발하였다. 개발한 프로그램은 해부학적 영상 및 기능 영상 간 mutual information, affine transform, non-rigid registration을 이용한 영상 정합 기능을 제공한다. 영상 정합 후 기준 영상과 정합된 영상에서 획득한 각 segmented bone의 겹치는 체적 비율 및 contour 간 평균 거리를 이용하여 정합도 평가도 가능하다. 잔여 종양이 있는 악성신경아교종 환자의 영상을 이용하여 소프트웨어의 기능을 평가하였을 때, bone segmentation과 contour 간 평균 거리 차이를 이용한 정합도는 각각 약 74%와 2.3 mm였으며, 수동정합을 이용하여 2~5% 정도의 정합도를 향상 시킬 수 있었다. 종양의 생물학적 특성을 치료 계획에 반영할 수 있도록, color map을 이용하여 rCBV map을 분석하였으며, ADC map에서 설정한 관심 영역의 평균 확산 계수와 표준 편차 등을 계산하여 종양의 예후 인자 및 악성도를 평가하였다. 두 기능 영상이 공통적으로 나타내는 종양 체적에서 얻은 생물학적 인자를 평면 위에 맵핑하여 종양의 특성을 쉽게 파악할 수 있는 multi-functional parametric map을 구성하였다. 또한 각기능 인자에 대응되는 악성 종양의 임계값을 적용하여 주변 종양 세포에 비하여 혈관 분포도는 높으면서 확산 계수는 낮아 악성 종양 세포일 확률이 높은 영역을 구분할 수 있었다. 각 기능 영상 위에서 설정한 생물학적 종양 체적 및 악성도가 높은 국소 체적은 해부학적 영상 위에 표시하여 dicom 파일로 출력할 수 있었다. 개발한 소프트웨어는 기능적 다중영상을 이용하여 생물학적 종양 체적을 해부학적 영상 위에 맵핑하는데 적용할 수 있으며, 해부학적 영상에서 파악하기 어려운 종양의 특성 변화들을 치료 계획에 활용할 수 있다. 나아가 개발한 소프트웨어를 이용하여, 한 종류의 영상을 참고하여 종양 체적을 결정했을 때 발생할 수 있는 오류를 줄이고, 치료 전이나 치료 과정에서 나타나는 종양의 조직학적, 생리학적 특성을 치료 계획에 접목하는데 활용할 수 있다.

수치표고모델, 3차원 카메라이미지자료 및 복사모델을 이용한 Sky Line과 Skyview Factor에 따른 강릉원주대학교 복사관측소 관측환경 분석 (Analysis of Observation Environment with Sky Line and Skyview Factor using Digital Elevation Model (DEM), 3-Dimensional Camera Image and Radiative Transfer Model at Radiation Site, Gangneung-Wonju National University)

  • 지준범;조일성;김부요;이규태;장정필
    • 대기
    • /
    • 제29권1호
    • /
    • pp.61-74
    • /
    • 2019
  • To investigate the observational environment, sky line and skyview factor (SVF) are calculated using a digital elevation model (DEM; 10 m spatial resolution) and 3 dimensional (3D) sky image at radiation site, Gangneung-Wonju National University (GWNU). Solar radiation is calculated using GWNU solar radiation model with and without the sky line and the SVF retrieved from the 3D sky image and DEM. When compared with the maximum sky line elevation from Skyview, the result from 3D camera is higher by $3^{\circ}$ and that from DEM is lower by $7^{\circ}$. The SVF calculated from 3D camera, DEM and Skyview is 0.991, 0.998, and 0.993, respectively. When the solar path is analyzed using astronomical solar map with time, the sky line by 3D camera shield the direct solar radiation up to $14^{\circ}$ with solar altitude at winter solstice. The solar radiation is calculated with minutely, and monthly and annual accumulated using the GWNU model. During the summer and winter solstice, the GWNU radiation site is shielded from direct solar radiation by the west mountain 40 and 60 minutes before sunset, respectively. The monthly difference between plane and real surface is up to $29.18M\;m^{-2}$ with 3D camera in November, while that with DEM is $4.87M\;m^{-2}$ in January. The difference in the annual accumulated solar radiation is $208.50M\;m^{-2}$ (2.65%) and $47.96M\;m^{-2}$ (0.63%) with direct solar radiation and $30.93M\;m^{-2}$ (0.58%) and $3.84M\;m^{-2}$ (0.07%) with global solar radiation, respectively.