• Title/Summary/Keyword: Radiation management area

Search Result 139, Processing Time 0.046 seconds

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter (방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가)

  • Kang, In-Seog;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.864-870
    • /
    • 2014
  • To propose a basis for the selection of personal dosimeters to measure radiation dose administration of radiation workers as a way to evaluate the usefulness dosimeter. For the dosimetry of the radiation workers 2012, during 1 year, 30 were radiation workers to measure personal dose. By personal exposure is measured cumulative dose, is investigated the performance of the TLD, PLD, OSLD. And comparing the measured value of each dosimeter dose and analyzed. Medical institutions, inspection work and quarterly confirmed the cumulative exposure dose of radiation workers. Using DAP and Ion-Chamber, to measure to compare TLD, PLD, OSLD dosimeter performance. A comparison of the directly through the X-ray dosimeter and The absolute value of the Ion-Chamber, OSLD more similar than in the TLD and PLD showed the dose values so the excellent ability to measure the results. Also in radiation generating area dose of radiation workers is higher than that in OSLD. Consequently, in terms of the individual exposure management OSLD is appropriated and beneficial than others.

A Study on the Satisfaction of Working Uniform on Nuclear Power Plant (원자력 발전소 작업복의 착용만족도에 관한 연구)

  • Kim, Younghee;Cho, Kyungsook
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.668-676
    • /
    • 2016
  • The purposes of this study were to investigate the satisfaction of working uniform in Nuclear Power Plant and to suggest the improvement of dissatisfaction. 150 workers in control area of Nuclear Power Plant were participated in survey and 30 questionnaires were asked and subjective description was allowed. 65%/35% Poly/Rayon coverall type working uniform was investigated for this survey which had been wearing usually and basically in control area in Nuclear Power Plant. According to the results, respondents were most highly dissatisfied with the wearing convenience aspect of current coverall among any other aspects, like textile and management. In wearing convenience aspects, wrist and ankle opening band system, the design, number and placement of pocket, waist belt design, the width of sleeve and pants, and ADR opening system were dissatisfied and requested for improvement. In textiles aspects, weight, protection from radiation materials, prevention from static electricity, moisture absorption, ventilation and flexibility/elasticity were dissatisfied and requested for improvement. In management aspect, washing uniform and size variation were dissatisfied and requested for improvement. Therefore, for more comfortable human interfaced working uniform, wearing convenience system as well as textile and management system must be compensated and should be newly developed for improving worker comfort, mobility, and productivity.

Periventricular Germinoma - Case Report - (뇌실주위 배아종 - 증례보고 -)

  • Kwon, Young-Yi;Park, Bong-Jin;Sung, Jung-Nam;Kim, Young-Joon;Cho, Maeng Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1245-1249
    • /
    • 2001
  • Germinomas of the central nervous system are rare embryonal tumors(accounting for less than 1% of intracranial neoplasms) that may be located in the pineal region, in the floor of the third ventricle, or in the suprasellar area. We report a case of germinoma developed in periventricular deep white matter without pineal region tumors or suprasellar masses. The 19-year-old male patient presented with slowly progressing headache, dizziness, photophobia, and dysarthria. Initial brain MRI revealed a irregular and dense enhancement from lateral ventricles to 4th ventricle. The stereotactic biopsy of tumor and histologic examination revealed the germinoma. Craniospinal axis radiation therapy was performed. After radiation therapy patient was improved and no neurologic sequelae was seen at discharge. Periventricular germinomas without pineal or suprasellar lesion are very rare. The radiation therapy, as in our case, is beneficial as with other intracranial germinomas. Stereotactic biopsy of periventricular germinoma provides precise pathologic diagnosis and thus allows more specific management.

  • PDF

Measurement of $\textrm{CO}_2$ Concentration and Leaf Area Index for Crop Photosynthesis Model in Sweet Pepper (단고추의 작물 광합성 모델을 위한 $\textrm{CO}_2$ 농도와 엽면적지 수 측정)

  • Lee, Beom-Seon;Chung, Soon-Ju;Jang, Hong-Gi
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.192-201
    • /
    • 1999
  • This study was aimed to introduce the measurement of $CO_2$ concentration and leaf area index in the phytotron for predicting the effect of CO.E, light and leaf area index on the instantaneous photosynthetic rate of sweet pepper with the existing ASKAM model. Measurements were made in 2 semi-closed phytotron compartments in which three different $CO_2$ concentrations were applied at random. Plants were grown on containers with circulating nutrient solution at 21$^{\circ}C$ and 80-95% relative humidity. The model estimates crop net $CO_2$ uptake for short time intervals during the day based on short-term data of daily radiation, temperature and $CO_2$ concentration. During the photosynthesis measurements, $CO_2$ concentrations in both compartments and in the basement were measured every minute. This was also done for the flow of pure $CO_2$ into the compartment, global radiation, photosynthetic active radiation inside the compartment, temperature and relative humidity. Crop growth models summarize our knowledge on crop behavior and have as such a wide range of applications in analysis, crop management and thus as a farm management tool.

  • PDF

An inquiry into dental personnel's Knowledge, attitude and behavior about the defense against dental radiation (치과 의료기관 종사자의 방사선 방어에 대한 지식, 태도 및 행위)

  • Kim, Sun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.15-29
    • /
    • 2004
  • The purpose of this study was to understand the relationship among knowledge, attitude, and behavior of dental personnel about the defense against dental radiation according to general features, and help them recognize the importance of defense against dental radiation. A questionnaire survey of 187 dental personnel who were working in 121 medical institutions such as university hospitals, general hospitals, hospitals, clinics, and public health centers in Seoul area was conducted from December 2002 to January 2003. Study findings are as follows: 1. The average knowledge score for the defense of radiation was 9.51(full score=14): By the demographic features, the know level for the defense of radiation was appeared to be different with the occupational category, age, academic background, workplace, year of working, and whether having the education of radiation or not. By questionnaire items, the knowledge for the defense of radiation was high in general, but for the item. 'the average amount of being bombed with radiation according occupations cannot be over 20mSv in a year for prescribed 5 years'. it was 18.7%: and for the item. 'the longer the length between focus and film. the less the amount of skin exposure', it was 40.6%. showing less knowledge for these two items. 2. The average attitude score for the defense of radiation was 64.24 (full score=75): By the demographic features, the attitude score was higher with respondents who were 31-35 years old. 11-15 years of working. and having radiation education. The attitude score by questionnaire items was generally high for all the items. 3. The average behavior score for the defense of radiation was 45.43: (a) By the demographic features, the behavior score for the defense of radiation was appeared to be higher with respondents who were dentists for occupational category, the aged for age, holding higher diploma for academic background, working in the university hospitals for workplace, and having longer occupational career for the year of working. (b) The behavior score for the defense of radiation by questionnaire items was lower than that of the attitude score for all the items. For the item, 'the amount of X-ray radiation is adjusted according to such conditions as patients' age, radiating areas, and kind of films', the score was 4.03; and for the item, 'Must receive the education of safety management of radiation periodically', the score was 1.73 and it was the lowest one. 4. As for the correlation among the knowledge, attitude, and behavior for the defense of radiation, the higher the level of knowledge and attitude, the higher the level of behavior.

  • PDF

A Study on the Additional Radiation Exposure Dose of kV X-ray Based Image Guided Radiotherapy (kV X선 기반 영상유도방사선치료의 추가 피폭선량에 관한 연구)

  • Gha-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1157-1164
    • /
    • 2023
  • This study measures the additional dose for each treatment area using kV X-ray based OBI (On-Board Imager) and CBCT (Cone-Beam CT), which have excellent spatial resolution and contrast, and evaluates the adequacy and stability of radiation management aspects of IGRT. The subjects of the experiment were examined with OBI and CBCT attached to a linear accelerator (Clinac IX), and ring-shaped Halcyon CBCT under imaging conditions for each treatment area, and the dose at the center was measured using an ion chamber. OBI single fraction dose was measured as 0.77 mGy in the head area, 3.04 mGy in the chest area, and 7.19 mGy in the pelvic area. The absorbed doses from the two devices, Clinac IX CBCT and Halcyon CBCT, were measured to be similar in the pelvic area, at 70.04 mGy and 70.45 mGy. and in chest CBCT, the Clinac IX absorbed dose (70.05 mGy) was higher than the Halcyon absorbed dose (21.01 mGy). The absorbed dose to the head area was also higher than that of Clinac IX (9.08 mGy) and Halcyon (5.44 mGy). In kV X-ray-based IGRT, additional radiation exposure due to photoelectric absorption may affect the overall volume of the treatment area, and caution is required.

Measurement of Absorbed Dose at the Tissue Surface from a Plain $^{90}Sr+^{90}Y$ Beta Sources (조직 표면에서의 베타선 흡수선량 측정)

  • Hah, Suck-Ho;Kim, Jeong-Mook;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.17-26
    • /
    • 1991
  • Beta ray $(^{90}Sr+^{90}Y)$ absorbed dose at tissue surface was measured from the distance of 30cm by use of extrapolation chamber. In the measurement, following factors were considered: effective area of collecting electrode, polarity effect, ion recombination and window attenuation. The measured absorbed dose rate at tissue surface was $1.493{\mu}Gy/sec$ with ${\pm}2.9%$.

  • PDF

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

A Survey of the Management of Patient Dose at Medical Center (의료기관의 환자 피폭선량 관리 실태조사)

  • Jeon, Go-Eun;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Medical radiation therapy using radioactive isotope I-131 is an extremely critical part of nuclear medicine. It is important to evaluate patients' radiation exposure dose for the safe handling of radiation in the medical area. Cautions related to patients' exposure to radiation are as follows. First, the dose should not exceed the level required for medical purpose. Second, unnecessary exposure should be avoided. Third, it should be considered carefully first whether the same medical purpose is attainable without the use of radiation. For these purposes, we need to evaluate patients' radiation exposure dose. Thus, in order to promote the safety of patients in medical wards, this study sampled air using an air sampler and measured the radioactivity of the sample using a gamma counter. According to the results of measuring I-131 in medical wards, the highest level, the average and the lowest level were $404.11Bq/m^3$, $228.27Bq/m^3$ and $126.17Bq/m^3$, respectively.

  • PDF