• Title/Summary/Keyword: Radiation loss

Search Result 958, Processing Time 0.03 seconds

Improved Method for Calculating Radiation Admittance of a Rectangular Microstrip Patch Antenna (구형 마이크로스트립 안테나의 개선된 복사 어드미턴스 계산방법)

  • Hong, Jae-Pyo;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.35-40
    • /
    • 1989
  • In this paper, a new method which simultaneously gives the radiation conductance and susceptance of the rectangular microstrip patch antenna. This solution is derived from the load admittance of the equivalent ${\pi}-$network circuit of the slitted parallel-plate waveguide filled with homogeneous dielectric. Our theoretical results for the radiation admittance are compared with other theoretical results. Also, our theoretical return loss and resonant frequency which are calculated by use of the equivalent transmission line model are in fairly good agreement with the experimental results.

  • PDF

Analysis of Magnetically Coupled Wireless Power Transmission for Maximum Efficiency

  • Kim, Chung-Ju;Lee, Bom-Son
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.156-160
    • /
    • 2011
  • We have proposed and analyzed an equivalent circuit for a magnetically coupled wireless power transmission (WPT) system between two loop resonators by considering its coupling coefficient and radiation-related parameters. A complete formulation is provided for all the necessary circuit parameters. The mechanism of radiation loss is sufficiently explained. The circuit and electromagnetic (EM) simulation results have been shown to be in good agreement. Based on the proposed circuit formulation, a specific load impedance for maximum WPT efficiency was found to exist. The proposed modeling of the WPT in terms of circuit characterizations provides sufficient insight into the problems associated with WPT.

A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis (방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구)

  • Hwang, I.K.;Kwon, K.H.;Song, S.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.784-791
    • /
    • 1995
  • This paper describes the counting-loss problem for radiation measurement Multi-channel analyzers and spectrometers adopt various techniques for compensation for counting-losses in process-ing the radiation pulses from a detector. Researchers hate tried to seek the best solution for the problem. However, any absolute solution has not been reached and vendors of radiation instruments use their own algorithms individually. This survey explains the various compensation algorithms with electronic implementation approach. Shortcomings and merits of each algorithm are also reviewed and a direction is suggested of the recommendable development strategy for counting-loss compensation.

  • PDF

Thermo Physiological responses of Far Infrared Ray Radiation Fabrics at outdoor in summer (옥외에서 원적외선 방사직물 착용시 온열생리반응)

  • 송명견;안필자;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • This study was performed to define the effects of Far Infrared Ray Radiation Fabrics as summer garments during outdoor work by human trial. One healthy male subject was volunteered for this study. Experimental garments consisted of three kinds of trousers (Cotton, Cotton/linen blended, Far Infrared Ray Radiation Fabric/wool blended) and basic garments (panty, socks, shirts, and dress shirts). The measurements were rectal temp., skin temp., microclimate inside clothing, heart rate, subjective sensation etc. The results were as follows : 1. Rectal temperature showed the lowest in Far Infrared Ray Radiation Fabrics among 3 garments. 2. Skin temperature (forehead, chest abdomen temp.) and mean skin temperature were lower in Far Infrared Ray Radiation Fabrics than in others, especially during early stage of work. 3. Heart rate showed lower value in Far Infrared Ray Radiation Fabrics than in others but there was no significance among the garments. 4. Humidity inside clothing and total weight loss showed the highest value in Far Infrared Ray Radiation Fabrics.

  • PDF

K-band Coplanar Stripline Resonator for Microwave Tunable Devices (마이크로파 가변 소자용 K-band Coplanar Stripline 공진기 설계)

  • Kang, Chong-Yun;Yoon, Seok-Jin;Kim, Hyun-Jai
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.6
    • /
    • pp.532-537
    • /
    • 2005
  • In order to develop a tunable resonator which can be easily operated by DC bias and applied for microwave tunable filters and devices using ferroelectric thin or thick films, the non conductor backed-and conductor backed- coplanar stripline resonators have been designed and analyzed. They have been designed to be operated at 25 GHz which involve coplanar stripline input and output ports. The resonators have been simulated and analyzed using Ansoft HFSS. The research has been focused on the Quality factor of the coplanar stripline resonator. The conductor Q, box Q, and radiation Q of the resonators have been analyzed and calculated according to the substrate thickness & conductor width of the resonators. From these parameters, the loss factors of the coplanar stripline resonator have been investigated. The conducting Q of the coplanar stripline resonator has no relation with the thickness of dielectric substrate and increases as the conductor width increases. The box Q has no much relation with the thickness of substrate and the conductor width, which is above 2000. The radiation loss increases as the thickness of substrate and the conductor width increase. To decrease the radiation loss of the coplanar stripline resonator, a conductor backed coplanar stripline resonator has been proposed which has the unloaded Q of 170.

Design of MTM Antennas using Equivalent Circuit Considering Radiation Loss (방사 손실 모델링을 이용한 MTM 안테나 설계)

  • Kim, Tack-Gyu;Lee, Bom-Son
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.1-7
    • /
    • 2008
  • In this paper, we propose a lossy MTM transmission line unit cell and retrieve the parameter values related with radiation effects. Based on this unit cell model, we plot dispersion diagrams and analyze resonance conditions. We also discuss the input impedance or admittance behavior when we terminate the load as open or short. Then, we examine the quality factor and return loss bandwidth. We also design a very compact unit cell antenna using the provided lossy MTM-TL model. The results based on EM simulations and measurements are shown to be in good agreement with those based on circuit simulation.

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

Input Impedance Calculation of the Power Line Communication System (전력선 통신 시스템의 입력 임피던스 계산)

  • Chun, Dong-wan;Lee, Jin-taek;Park, Young-Jin;Kim, Kwan-Ho;Shin, Chull-Chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.983-990
    • /
    • 2004
  • In this paper, we calculated the input impedance of the power line communication(PLC) networks using medium voltage power line. First of all, we proposed input and output teoninal model of PLC network, and calculated the input impedance applying the attenuation constants by radiation loss, conductor loss, dielectric loss. From the calculation result, we knew that the attenuation by radiation loss was largest, and the input impedance appears like a standing wave fonn with a fixed cycle because the high reflection at the input terminal for the characteristic impedance of the power line is very large. And also the cycle of input impedance depends on the coaxial cable length, and the amplitude depends on the characteristic impedance of power line and losses. From the measurement result, calculated result was very similar to the measured result.

Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling (HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구)

  • 박재홍;권용하;김영수;박성출
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

DC Link Switch Loss Analyses according to Circuit Structures of the Boost Converter for Photovoltaic Generation System (태양광 발전 시스템을 위한 부스트 컨버터의 회로 구성에 따른 직류측 스위치 손실 분석)

  • Lee, Seung-Yo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.192-198
    • /
    • 2012
  • Switch losses directly affect the efficiency of power conversion systems and those have big differences according to the power consumed by load systems and the structures of power conversion circuits. In this paper, analyses for switch losses in DC link converter are performed based on the circuit structures of the DC/DC converter in photovoltaic generation system whose output power is varied according to the amount of solar radiation, temperature and partial shade on the solar modules. Boost converter is adopted as a DC link converter topology of the photovoltaic generation system and the loss analyses for the switches used in the boost converters are performed according to the circuit structures. Analyses like the things performed in this paper will be a prerequisite to designing the photovoltaic generation system whose output power is changed according to the environmental variations.