• 제목/요약/키워드: Radiation level

검색결과 1,833건 처리시간 0.028초

Vibroacoustic response of thin power law indexed functionally graded plates

  • Baij Nath Singh;Vinayak Ranjan;R.N. Hota
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.299-318
    • /
    • 2024
  • The main objective of this paper is to compute the far-field acoustic radiation (sound radiation) of functionally graded plates (FGM) loaded by sinusoidally varying point load subjected to the arbitrary boundary condition is carried out. The governing differential equations for thin functionally graded plates (FGM) are derived using classical plate theory (CPT) and Rayleigh integral using the elemental radiator approach. Four cases, segregated on power-law index k=0,1,5,10, are studied. A novel approach is illustrated to compute sound fields of vibrating FGM plates using the physical neutral surface with an elemental radiator approach. The material properties of the FGM plate for all cases are calculated considering the power law indexes. An in-house MATLAB code is written to compute the natural frequencies, normal surface velocities, and sound radiation fields are analytically calculated using semi-analytical formulation. Ansys is used to validate the computed sound power level. The parametric effects of the power law index, modulus ratios, different constituent of FGM plates, boundary conditions, damping loss factor on the sound power level, and radiation efficiency is illustrated. This work is the benchmark approach that clearly explains how to calculate acoustic fields using a solid layered FGM model in ANSYS ACT. It shows that it is possible to asymptotically stabilize the structure by controlling the intermittent layers' stiffness. It is found that sound fields radiated by the elemental radiators approach in MATLAB, ANSYS and literatures are in good agreement. The main novelty of this research is that the FGM plate is analyzed in the low-frequency range, where the stiffness-controlled region governs the whole analysis. It is concluded that a clamped mono-ceramic FGM plate radiates a lesser sound power level and higher radiation efficiency than a mono-metallic or metal-rich FGM plate due to higher stiffness. It is found that change in damping loss factor does not affect the same constituents of FGM plates but has significant effects on the different constituents of FGM plates.

원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구 (A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.552-558
    • /
    • 2014
  • 본 논문에서는 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계방법을 제안한다. 제안된 ZigBee 원칩형 통신모듈 설계는 ZigBee 시스템 구성을 위해 일반적으로 사용되는 2개의 칩 제어 프로세서와 ZigBee RF 디바이스로 구성되는 방식을 한 개의 칩 모듈로 설계한다. 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈은 무선통신 통합제어부, 센서 및 고전압 발생부, 충전 및 전원회로부, 유선통신부, RF 회로부 및 안테나부 등으로 구성된다. 무선통신 통합제어부는 ZigBee를 위한 무선통신 제어 기능 및 방사선 측정 및 제어를 위한 기능을 수행한다. 센서 및 고전압 발생부는 2차에 걸쳐 500V의 고전압을 생성하여 GM Tube를 통해 감지된 방사선에 대한 펄스를 증폭 필터링 하는 기능을 수행한다. 충전 및 전원회로부는 리튬이온 배터리의 충전 및 원칩 프로세서에 전원을 공급하는 기능을 수행한다. 유선통신부는 PC와의 인터페이스 및 디버깅을 위한 USB 인터페이스 및 원거리 유선 통신이 가능하도록 RS-485/422 인터페이스 기능을 수행한다. RF 회로부 및 안테나부는 칩안테나를 적용할 수 있도록 RLC 수동소자를 적용하여 BALUN 및 안테나 임피던스 매칭 회로를 구성하여 무선통신이 가능하도록 한다. 제안된 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈을 설계 실험한 결과, 10m, 100m 구간에서 모두 데이터가 정상적으로 전송되어서 원격 방사선량 측정이 되었음을 확인할 수가 있었다. 또한 낮은 소비전류와 적은 비용으로 원격 방사선량 측정환경을 구축할 수 있었다. 따라서 방사선 측정장치의 선형성 확보 및 장치의 소형화를 통해 안정적인 방사선 측정 및 실시간 모니터링 환경을 구축할 수가 있었다.

Management of Radiation Injuries by Panax ginseng Extract

  • Verma, Preeti;Jahan, Swafiya;Kim, Tae-Hawn;Goyal, Pradeep Kumar
    • Journal of Ginseng Research
    • /
    • 제35권3호
    • /
    • pp.261-271
    • /
    • 2011
  • Chemical radiation protection is an important strategy to protect living beings against the deleterious effects of radiation. In the present study, the radioprotective effect of hydro-alcoholic extract of Panax ginseng extract (PGR-HAE) was studied on radiation-induced deleterious alterations in Swiss albino mice. Oral administration of such extract (25 mg/kg b wt/day/animal) for 5 consecutive days, half an h. before whole-body exposure to 6 Gy gamma radiation, enhanced the 30 days survival and also inhibited the radiogenic sickness, weight loss and life shortening. PGR-HAE ameliorated radiation induced depletion in blood constituents at different necropsy intervals between 12 h to 30 d, and significantly increased the number of femoral spleen colony forming units that survived after irradiation. Furthermore, it checked depletion of glutathione and antioxidant enzymes (superoxide dismutase, catalase, and glutathione S-transferase) as well as elevation of lipid peroxidation (LPO) level in blood and liver. The significant reduction in the yield of LPO demonstrates that PGR-HAE protects the membranes against radiation-induced oxidative damage. These findings conclude that such plant extract provides significant radioprotection, and it may be potentially valuable in the prevention of injuries caused during planned and unplanned radiation exposure.

완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발 (Development of Radiation Free Soft X-Ray Ionizer with Ion Control)

  • 정필훈;이동훈
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

국립공원의 해발고도에 따른 환경방사선 측정 (Measurement of Environmental Radiation according to Altitude above Sea Level in National Park)

  • 지태정;이인식
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.694-701
    • /
    • 2012
  • 본 연구는 국가환경방사선 자동감시망이 설치되지 않은 국립공원의 산악 지역을 대상으로 환경방사선을 측정하였다. 측정 방법은 지표 1m 높이에서 공간선량과 지표면에서의 지표선량을 측정하였다. 국립공원 선정은 중부지역과 남부지역을 같은 분포로 하여 전국에 10곳을 선정하였다. 측정장비는 감마선측정에 활용되는 INTERCEPTOR$^{TM}$(Thermo, USA, 2006)를 사용하였다. 방사선측정은 국립공원 입구와 정상에서는 필수적으로 측정하였고, 그 외 지점은 해발 고도를 500m 단위로 구분하여 탐방객이 많이 다니는 곳에서 측정하였다. 측정횟수는 각 지점에서 2분간 장비를 안정시킨 후 5회 이상 측정하였다. 측정결과, 공간감마선량의 경우 1,000m 이하 국립공원에서는 해발 고도 500m 지점에서 높은 선량이 측정되었다. 그 중 북한산, 계룡산, 월출산에서 $0.23{\mu}Svh^{-1}$ 이상인 것으로 확인되었다. 1,000m 이상의 국립공원에서는 설악산 1,500m 지점에서 $1.77{\mu}Svh^{-1}$로 측정되어 백그라운드 기준 선량보다 10배 이상 증가하였다. 선량에 유의한 변화를 보이지 않은 국립공원은 내장산, 소백산, 지리산으로 확인되었다. 환경방사선량이 낮게 측정된 산은 가야산 정상(1,430m)에서 $0.04{\mu}Svh^{-1}$, 한라산 정상(1,950m)에서 $0.03{\mu}Svh^{-1}$인 것으로 확인되었다. 지표선량 측정에서도 중간 높이인 500m, 1,000m에서 높게 측정되었다. 지각 구성물질의 종류에 따른 측정에서는 암석으로 구성된 국립공원에서 높은 선량으로 조사되었으며, 화산활동이 일어났던 한라산에서는 환경방사선량이 낮게 측정되었다.

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발 (Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.96-100
    • /
    • 2015
  • In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.

국제기준을 적응한 치료계획시스템 정확성 평가 (Estimation of RTP Accuracy Based the International Reference Level)

  • 오영기;김기환;정동혁;최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제19권2호
    • /
    • pp.113-119
    • /
    • 2008
  • 본 연구에서는 6종에 대한 RTP의 실험 결과에 대하여 오차를 평가하고 AAPM Report-62의 평가 항목에 적용하여 RTP 오차의 허용범위 여부를 조사하였다. 이를 위하여 NDR (Normalized dose rate) 개념을 도입하여 RTP 계산값과 측정값을 동일한 기준으로 비교할 수 있도록 하였다. 평가결과 대부분의 RTP들은 차폐조사면과 불균질 물질의 계산에서 허용범위 이내의 오차를 보였으나 표면 불균일성에 대해서는 대부분 허용범위를 초과하는 것으로 나타났다.

  • PDF

원자력병원(原子力病院) 싸이클로트론 중성자선(中性子線) 치료실(治療室)의 방사선(放射線) 방어(防禦)에 관한 총합적(總合的) 평가(評價) (Compositional Qualification of Radiation Protection in Neutron Radiotherapy Room with KCCH Cyclotron)

  • 유성열;조철구;고경환
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.45-50
    • /
    • 1989
  • 원자력병원 싸이클로트른 중성자선(中性子線) 치료실의 방사선 준위(準位)를 측정함으로써 방사선 안전도를 검토하여 보았다. 중성자선 치료실내 방사선 노출은 주로 isocentric gantry에 내장된 중성자선 표적(標的)과 조사야(照射野)를 결정하는 collimator의 방사화(放射化)로 인한 잔류방사능(殘留放射能) (remanent radioactivity)에 의해 결정 된다. 측정결과 선량율(線量率)은 과다하지 않았고 개인 집적선량(集積線量)도 허용치 이내였다. 방사선 작업종사자로서의 의료기사는 환자치료 시 매 조사(照射) 완료 직후부터 5분간 멸살(滅殺)시간을 갖도록 조치하였다.

  • PDF

전리방사선이 세포질 소기관의 미세구조변화와 기전에 미치는 영향 (The Effect of Ionizing Radiation on the Ultrastructural Changes and Mechanism on the Cytoplasmic Organelles)

  • 이무석;이종규;남지호;하태영;임영현;길상형
    • 생명과학회지
    • /
    • 제27권6호
    • /
    • pp.708-725
    • /
    • 2017
  • 전리방사선은 물질과 상호작용하여 원자내의 중성자나 양성자, 궤도전자를 충분히 제거시킬 수 있는 에너지이다. 이와 같은 전리방사선은 DNA이나 세포질 소기관과 세포질의 방사선 분해 생성물을 통해 직접적, 간접적으로 상호작용하여 분자구조를 변화시키는 산화적 대사를 일으킨다. 이러한 전리 현상은 분자수준에서 조직을 손상시키고, 세포 기능을 파괴할 수 있다. 따라서, 전리방사선에 의해 유도된 이온채널과 수송 변형이 보고되고 있다. 이러한 현상이 항상성을 유지하기 위한 생화학적 과정을 무너뜨리면, 유도된 생물학적 변화가 지속되고 후대로 영향을 미친다. 또한, 전리방사선의 영향으로 형성된 활성산소는 세포연접을 통해 인접세포로 퍼져 나갈 수 있다. 방사선량, 선량률, 선질에 따라 이러한 메커니즘이 충분히 방어할 수도 있고 그렇지 않을 수도 있다. 본 총설에서는 방사선생물학의 개념을 뒷받침하는 전리방사선의 세포수준에서 생물학적 효과에 대한 보고서를 간략히 알아보았다. 전리방사선의 생물학적 효과를 잘 이해하면 방사선을 잘 이용할 수 있고, 방사선피폭으로부터 더 나은 방호를 할 수 있을 것이다.