• Title/Summary/Keyword: Radiation dose distribution

Search Result 742, Processing Time 0.023 seconds

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

A Study of Total Dose in Intensity Modulation Radiation Therapy (선량강도 조절법을 이용한 방사선치료에서 총선량에 관한 고찰)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.85-90
    • /
    • 2000
  • In radiation therapy, the effects of radiation are decided total dose, total treatment times and number of radiation dose fractions. We considered that total dose, total treatment times and number of radiation dose fractions in intensity modulation radiation therapy(IMRT) infuence tumor cell killing. The goal of three dimensional conformal radiation therapy(3DCRT) in radiation therapy is to conform the partial distribution of the prescribed radiation dose to the precise 3D configuration of the tumor, and at the same time, to minimize the dose to the surrounding normal tissues. To optimize treatment volume of tumor, treatment volume will be same tumor volume. All IMRT compare to conventional treatment plus boost IMRT when total dose irradiated 75 - 90 Gy. Because of biological effect, total dose are decreased 12.5 - l5Gy in all IMRT.

  • PDF

Characteristics of Dose Distribution at Junctional Area Using the Divergency Cutout Block in the Abutted Field of Photon and Electron Beams (광자선과 전자선의 인접조사에서 선속 퍼짐현상이 고려된 전자선 차폐물을 이용한 접합 조사면의 선량분포 특성)

  • Im, In-Chul;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.168-173
    • /
    • 2011
  • This study investigated characteristics of dose distribution at junction field of X-ray and electron beams according to the method for fabricating the insert block on the electron cone. Insert block were fabricated to the divergency cutout block and the straight cutout block. For the 6 MV X-ray and 10 MeV nominal energy of electron beam, we was adjacent to the light field of X-ray and electron beam at a surface of matrix chamber and measured to beam profile of abutted field in the 0, 1, 2, 3 cm measurement depth. As a result, characteristics of dose distribution at junction field, straight block was existent that over dose area exceed the give dose more than 5% and under dose area with a rapid change in dose distribution. However, divergency block had remarkably decreased the over dose area caused by the lateral scattering effects of decrease, and being existed uniformity dose distribution in the junction field. Therefore, divergency block were the benefits of radiation dose delivery, in order to applied the clinical, measurement of electron beams according to the fabrication method of the block should be considered carefully.

Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam (횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향)

  • Oh, Young Kee;Kim, Ki Hwan;Shin, Kyo Chul;Kim, Jhin Kee;Kim, Jeung Kee;Jeong, Dong Hyeok;Cho, Mun Jun;Kim, Jun Sang;Yoon, Sun Min;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.209-213
    • /
    • 2007
  • In this work we have measured the dose distribution and the percent depth dose of 20 MeV electron beam using the X-OMAT films in order to verify the effects of transverse magnetic field on high energy elecrtron beam in a phantom. The result shows about 30% increase of the percent depth dose at 4.5 cm depth under the transverse magnetic field of 1.5 Tesla at 7.5 cm depth. We have verified that these were in an agreement with other theoretical results.

  • PDF

Dose Attenuation in the Mid-Cranial Fossa with 6 MV Photon Beam Irradiations (6 MV X-선 조사시 중두개와에서의 선량감쇠)

  • Park, Jeong-Ho;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.125-131
    • /
    • 1990
  • In X-ray irradiation, dose distribution depends on multiple parameters, one of them being tissue inhomogeneity to change the dose significantly. considerable dose attenuation through the mid-cranial fossa is expected because of various bony structures in it. Dose distribution around the mid-cranial fossa, following irradiation with 6 MV photon beam, was measured with LiF TLD micro-rod, and compared with the expected dose inthe same sites. In our calculation with $C_f$(correction factor), the expected dose attenuation revealed about $3.74\%$ per 1 cm thickness of bone tissue. And the differences between the expected dose with correction for bone tissue and the measured dose by TLD was small, agreeing within an average variation of $\pm0.21\%$.

  • PDF

The usefulness of Forward IMRT for Head and Neck Cancer (두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰)

  • Baek Geum Mun;Kim Dae Sup;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 2003
  • I. Purpose The dose distribution in normal tissues and target lesions is very important in the treatment planning. To make the uniform dose distribution in target lesions, many methods has been used. Especially in the head and neck, the dose inhomogeneity at the skin surface should be corrected. Conventional methods have a limitation in delivering the enough doses to the planning target volume (PTV) with minimized dose to the parotid gland and spinal cord. In this study, we investigated the feasibility and the practical QA methods of the forward IMRT. II. Material and Methods The treatment plan of the forward IMRT with the partial block technique using the dynamic multi-leaf collimator (dMLC) for the patients with the nasopharyngeal cancer was verified using the dose volume histogram (DVH). The films and pinpoint chamber were used for the accurate dose verification. III. Results As a result of verifying the DVH for the 2-D treatment plan with the forward IMRT, the dose to the both parotid gland and spinal cord were reduced. So the forward IMRT could save the normal tissues and optimize the treatment. Forward IMRT can use the 3-D treatment planning system and easily assure the quality, so it is easily accessible comparing with inverse IMRT IV. Conclusion The forward IMRT could make the uniform dose in the PTV while maintaining under the tolerance dose in the normal tissues comparing with the 2-D treatment.

  • PDF

Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen (이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Dose Volume Histogram Analysis for Comparison of Usability of Linear Accelerator Flattening Filter

  • Ji, Yun-Sang;Dong, Kyung-Rae;Ryu, Jae-Kwang;Choi, Ji-Won;Kim, Mi-Hyun
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.297-302
    • /
    • 2018
  • The wedge filter has two movements, fixed and dynamic. In this study, the depth dose distribution was analyzed to determine the stability of the dose distribution and dose volume histograms obtained by evaluating the usability of the critical normal tissue dose around the tumor dose. The depth dose was analyzed from the dose distribution from a Linac (6 MV and 10 MV irradiation field of energy $20{\times}20cm^2$, wedge filter with a SSD of 100 cm and $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ Y1-in (Left -7 cm), Y2-out(Right +7 cm). To analyze the fluctuations of the depth dose, a fixed wedge and dynamic wedge toe portion was examined according to the energy and angle because the size of the fluctuations was included in the error bound and did not show significant differences. The neck, breast, and pelvic dosimetry in tumor tissue are measured more commonly with a dynamic wedge than a fixed wedge presumably due to the error range. On the other hand, dosimetry of the surrounding normal tissue is more common using a fixed wedge than with a dynamic wedge.

The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution (2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향)

  • Kim, Sung Joon;Lee, Seoung Jun;Park, In Kyu;Lee, Jeong Eun;Park, Shin Hyung;Seol, Ki Ho;Kim, Jae Chul
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • We evaluated the influence of volume effect on the measurement of IMRT dose distribution by comparing a 2D-array ion chamber and other dosimeters. Matrix phantom which is a 2D-array ion chamber having volume effect was compared with beam image system and film for the measurement of dose distribution. Five intensity-modulated radiation therapy plans were created using five fields in thevirtual phantom. The measured dose distribution was compared with the calculated one by radiation treatment planning system and analysis program. We evaluated the conformity of dose distribution by calculating correlation coefficients and gamma values. The highest error rate of 1.3% was associated with matrix phantom in which volume effect in small field sizes was substantial.

Dose Distributions for Ll NAC Radiosurgery with Dynamically Shaping Fields (선형가속기를 이용한 방사선 수술시 Dynamical Field Shaping에 의한 선량분포)

  • Suh Tae Suk;Yoon Sei Chul;Kim Moon Chan;Jang Hong Seok;PArk Yong Whee;Shinn Kyung Sub;Park Charn Il;Ha Sung Whan;Kang Wee Saing
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.431-437
    • /
    • 1993
  • An important problem in radiosurgery is the utilization of the proper beam parameters, to which dose shape is sensitive. Streotactic radiosurgery techniques for a linear accelerator typically, use circular radiation fields with multiple arcs to produce an spherical radiation distribution. Target volumes are irregular in shape for a certain case, and spherical distributions can irradiate normal tissues to high dose as well as the target region. The current improvement to dose distribution utilizes treating multiple isocenters or weighting various arcs to change treatment volume shape. in this paper another promising study relies upon dynamically shaping the treatment beam to fit the beam's eye view of the target. This conformal irradiation technique was evaluated by means of visual three dimensional dose distribution, dose volume histograms to the target volume and surrounding normal brain. It is shown that using even less arcs than multiple isocenter irradiation technique, the conformal therapy yields comparable dose gradients and superior homogeneity of dose within the target volume.

  • PDF