• 제목/요약/키워드: Radiation correction method

검색결과 122건 처리시간 0.03초

솔라패널을 이용한 라디오존데 온도센서의 일사보정 (Compensation for The Solar Radiation Effect of Radiosonde's Temperature Sensor Using Solar Panel)

  • 박명석;이진욱;정세진;장재원
    • 대기
    • /
    • 제29권3호
    • /
    • pp.283-294
    • /
    • 2019
  • For the upper air observations, a temperature measurement using radiosonde is a common method, and the compensation of solar radiation effects in the radiosonde temperature sensor is an important factor. In this paper, we present various experiments and compensation methods of the radiosonde temperature sensor to overcome the errors caused by the movement of the radiosonde rotation, etc. The methods and procedures of this study are as follows. First, we used the solar simulator to analyze the temperature variation and solar effect of the temperature sensor in the radiosonde according to the insolation. We also analyzed the temperature variation and solar effect of the temperature sensor according to the incident angle between the solar simulator and radiosonde. Second, we measured and analyzed solar radiation absorbed by solar cells attached to radiosonde. Third, we present combined compensate solution of the first and the second experiment results, to overcome errors caused by insolation effects in the radiosonde temperature sensors. Fourth, we compared that the reference temperature in similar environment with the upper air conditions, to verify the new radiated compensation performance of the radiosonde temperature sensor. Finally, the radiosonde fabricated in this study was raised to the atmosphere, and the laser correction algorithm proposed through experiments was reviewed. As a result of the radiosonde SRS-10 produced in this study, the temperature deviation from Vaisala RS92 was $0.057^{\circ}C$ in nighttime observation, $0.17^{\circ}C$ in daytime observation, It is expected that the GRUAN under WMO will be able to obtain a high test rating of 5.0.

방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템 (Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods)

  • 윤용현;조문재;김용태;이명호
    • 한국음향학회지
    • /
    • 제29권6호
    • /
    • pp.355-364
    • /
    • 2010
  • 초음파 진단장치의 음향출력 특성은 전기음향 변환 장치인 배열 탐침자의 성능에 크게 영향을 받으며, 생물학적안전 측면에서 매우 중요하다. 본 논문에서는 초음파 진단장치용 배열 탐침자로부터 방사되는 음향파워를 소자별로 측정할 수 있는 자동화 시스템을 구성하였으며, 곡선형 탐침자의 경우 각 소자의 지향성이 측정에 미치는 영향을 확인하고 이를 보정하는 기법을 개발하였다. 선형, 위상형, 곡선형 배열 탐침자를 대상으로 음향파워 측정결과, 본 논문에서 제시하는 측정기법은 배열 탐침자의 음향파워 특성을 평가하는데 적합함을 확인하였다.

단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구 (Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study)

  • 김진성;주상규;홍채선;정재원;손기홍;신정석;신은혁;안성환;한영이;최두호
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.85-91
    • /
    • 2013
  • 초고압 전산화단층촬영(megavoltage computed tomography, MVCT)이 단층치료(Tomotherapy) 환자의 치료 자세 교정 방법으로 사용되고 있다. MVCT는 부가적인 방사선 피폭뿐만 아니라 전체 치료 시간이 길어지는 단점을 가지고 있다. 이러한 문제점 해결을 위해 비디오 영상기반 환자 치료 자세 교정 시스템(video image-guided setup system, VIGS)을 개발했다. 단층치료 장치내 갠트리에 직각으로 2대의 비디오 카메라를 장착하고 이로부터 얻은 영상을 이용하여 환자의 자세 오차를 측정하는 프로그램을 자체 개발했다. 개발된 시스템은 사용자에 의해 정의된 관심 영역에서의 에지 검출(edge detection) 결과를 기반으로 자동 정합을 통해 자세 오차를 찾도록 고안되었다. 두경부 환자를 묘사하기 위해 휴먼 팬톰을 이용하여 컴퓨터 단층 치료계획 영상을 획득한 후 전산화 치료계획을 수행했다. 실제 치료 상태를 재현하기 위해 고정 용구를 이용하여 팬톰을 고정했으며 전산화치료계획 결과로 부터 팬톰 자세 검증을 위한 기준 MVCT 영상을 획득했다. 팬톰을 치료 위치에 위치시킨 후 MVCT 영상을 얻고 이를 기준 MVCT영상과 비교하여 치료계획시와 동일환 자세가 되도록 위치를 교정했다. 교정된 자세에서 VGIS를 이용하여 기준 비디오 영상을 획득했다. 10회 걸쳐 MVCT 영상을 이용한 자세 교정과 VIGS를 이용한 비디오 영상기반 자세 교정을 각각 수행하여 두 방법간의 교정 값 차이(상관 분석)와 분석 시간을 비교했다. 팬톰 위치 교정 시간은 VIGS 시스템($41.7{\pm}11.2$ seconds)이 MVCT 방법($420{\pm}6$ seconds)에 비해 현저히 적게 조사됐다(p<0.05). 하지만 두 방법간의 위치 오차 분석 결과 통계적으로 유의한 차이는 보이지 않았다(x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). VIGS시스템이 짧은 시간에 정확한 위치 오차 감지 능력을 보여 이의 개발이 단층치료의 절차를 효율적으로 개선하는데 효과적일 것으로 생각된다.

액체섬광계수기 장비의 계측조건 확립에 관한 연구 (Research on Measurement Condition Establishment of a Liquid Scintillation Counter System)

  • 박응섭;한상준;이승진;김희강;이나영;문지연
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.155-164
    • /
    • 2006
  • 액체섬광계수기를 이용하여 환경시료를 분석하는 모든 과정에서 계측 조건 및 방법론 차이에 의한 불확실성이 존재할 수 있을 것으로 판단하여 본 연구에서는 이에 대한 평가를 정량적으로 수행함으로써 비교적 정확하게 환경시료를 분석하고자 하였다. 이를 위해 결과에 영향을 미칠 수 있는 변수를 도출한 후 각 변수에 대한 영향을 평가한 결과, 분석시료를 제조하는 과정에서의 인적 및 물리적인 불확실성은 무시할 정도로 미미하였고, 측정용기의 무게 차이에 따른 영향은 나타나지 않았다. 외부선원의 조사시간을 단계적으로 증가시킨 결과 시간이 증가함에 따라 데이터의 분산 정도는 감소하면서 $75{\sim}90$ sec에서 포화상태에 도달하였고, Repeat 방법이 Replicate 방법에 비해 데이터의 신뢰성이 높게 나타났다. 또한 방치시간에 따른 영향을 평가한 결과 분석 냉 암소에서 약 1,000 min 이상 방치시킨 후 시료에 대한 분석을 수행해야만 잔상 및 이상 유동에 의한 영향은 거의 없는 것을 알 수 있었고, 결과에 대한 검증을 수행하기 위해 방사능 오차분석과 함께 Chi-square test를 수행한 결과 신뢰성 있는 결과를 보여주었으며 이러한 분석 및 검증 결과에 근거하여 계측 결과에 대한 오차 및 불확실성을 감소시킬 수 있었다.

일사 수광량 보정에 의한 산악지대 매시기온의 공간내삽 (Spatial Interpolation of Hourly Air Temperature over Sloping Surfaces Based on a Solar Irradiance Correction)

  • 정유란;윤진일
    • 한국농림기상학회지
    • /
    • 제4권2호
    • /
    • pp.95-102
    • /
    • 2002
  • 관측밀도가 낮고 지형이 복잡한 산악지역을 대상으로 낮 시간대 기온의 경시변화를 기존의 방법으로 내삽할 경우 일사수광량의 불균일한 분포 때문에 심각한 추정오차가 발생할 수 있다. 이를 해결하기 위해 기존의 기온감율을 고려한 거리역산가중 내삽모형에 일사수광량 보정항을 추가하고 오차경감 정도를 평가하였다. 강원도 평창군 일대 14km$\times$22km 지역을 10m 해상도의 수치고도모형으로 표현하고, 각 격자점에 대해 태양과 지표면 사이의 기하학적 관계를 바탕으로 시간대별 실제 일사 수광량을 직달, 산란, 반사 등 성분별로 계산하였다. 수평면 일사량과의 편차를 산출한 다음 이 지역에서 경험적으로 얻은 일사-기온 변환당량을 적용하여 보정값을 얻었다. 기존의 방법에 의해 내삽된 기온값에 이 보정값을 적용하여 대상지역 전역의 기온분포도를 작성하였다. 대상 지역 내 경사향이 서로 다른 8개 지점에서 기온을 측정하여 기온분포도와 비교한 결과 추정오차가 크게 줄어들었음을 확인할 수 있었다.

SOME PROPERTIES OF SIMEX ESTIMATOR IN PARTIALLY LINEAR MEASUREMENT ERROR MODEL

  • Meeseon Jeong;Kim, Choongrak
    • Journal of the Korean Statistical Society
    • /
    • 제32권1호
    • /
    • pp.85-92
    • /
    • 2003
  • We consider the partially linear model E(Y) : X$^{t}$ $\beta$+η(Z) when the X's are measured with additive error. The semiparametric likelihood estimation ignoring the measurement error gives inconsistent estimator for both $\beta$ and η(.). In this paper we suggest the SIMEX estimator for f to correct the bias induced by measurement error, and explore its properties. We show that the rational linear extrapolant is proper in extrapolation step in the sense that the SIMEX method under this extrapolant gives consistent estimator It is also shown that the SIMEX estimator is asymptotically equivalent to the semiparametric version of the usual parametric correction for attenuation suggested by Liang et al. (1999) A simulation study is given to compare two variance estimating methods for SIMEX estimator.

고온 환경에서의 적외선 열화상 측정에 관한 연구 (Research on Measurement of Infrared Thermograpphy under High Temperature Condition)

  • 이준식;전재욱
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진 (PTV Margins for Prostate Treatments with an Endorectal Balloon)

  • 김희정;정진범;하성환;김재성;예성준
    • Radiation Oncology Journal
    • /
    • 제28권3호
    • /
    • pp.166-176
    • /
    • 2010
  • 목 적: 직장 내 풍선삽입을 하는 전립선 암 환자의 3차원 입체조형방사선치료(3D CRT)와 세기조절치료에 대한 적절한 계획표적부피 마진을 구하기 위하여 본 연구를 수행하였다. 대상 및 방법: 환자는 반듯이 누운 자세에서 치료계획용 CT 촬영과 매 치료 전에 환자의 직장에 풍선이 삽입되었고 70 mL의 공기로 풍선을 팽창시켰다. Anterior-posterior (AP)와 측면에서의 전자식 조사문영상 이미지와 디지털 화재구성사진을 이용하여 치료간 환자 치료위치 및 풍선의 위치 변화를 분석하였다. 두 이미지를 정합하기 위하여 Visual $C^{++}$ 기반의 프로그램을 개발하여 사용하였다. 기존의 방법을 기반으로 풍선에 의한 선량 흐려짐 효과를 고려한 계획표적부피 마진을 구하는 방법 고안하였다. 결 과: 환자치료위치의 치료간 변화는 모든 방향에서 평균 1 mm 이내로 나타났다. 풍선의 치료간 변화는 left-right (LR) 방향에 비해 superior-inferior (SI)와 AP 방향으로 크게 나타났다. 풍선의 무작위오차를 포함시켜 새로 고안된 1차원 계획표적부피 마진 구하는 방법을 사용하여 마진을 구한 결과, 3D CRT의 경우에는 LR 방향으로 3.0 mm, SI 방향으로 8.2 mm, AP 방향으로 8.5 mm로 계산되었다. Intensity modulated radiation therapy의 경우, LR 방향으로 4.1 mm, SI 방향으로 7.9 mm, AP 방향으로 10.3 mm로 마진이 계산되었다. 결 론: 풍선의 무작위오차는 전립선 모양의 변형을 일으켜서 선량분포에 영향을 준다. 따라서, 새로 고안된 계획표적부피 마진을 구하는 방법에는 풍선에 의한 선량 흐려짐 효과가 고려되었다. 이 방법은 풍선의 무작위오차만 계산에 포함하기 때문에 풍선의 계통오차에 대한 보정을 전제로 한다.

다양한 두께의 알루미늄 판을 이용한 MTF 측정에 관한 연구 (Modulation Transfer Function with Aluminum Sheets of Varying Thickness)

  • 이동주;김미영;문영민;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.55-63
    • /
    • 2016
  • 본 연구에서는 방사선치료기용 CBCT의 영상과 같이 해상도가 낮은 경우에 적용할 수 있는 MTF (modulation transfer function) 평가 방법을 고안하였다. 본 연구에서는 두꺼운 알루미늄 판의 영상을 이용하여 중복 표본(oversampling) 방법과 두께 보정 방법을 적용하여 MTF를 결정하였다. 다양한 알루미늄 판의 두께(0.3~1.2 mm)에 대해 MTF를 분석하였으며 경사 영상과 평행 영상의 경우에 대해서도 비교하였다. 연구 결과 치료계획용 CT인 경우에 알루미늄의 두께가 0.8 mm 이하 일 경우 MTF 측정이 가능한 것으로 나타났다. 따라서 두꺼운 알루미늄 판과 두께 보정을 이용한 MTF 측정이 CT 영상에서 가능하였다.

설마천 유역 CO2 Flux 실측 자료에 의한 총일차생산성 (GPP)과 MODIS GPP간의 비교 평가 (Evaluation of MODIS Gross Primary Production (GPP) by Comparing with GPP from CO2 Flux Data Measured in a Mixed Forest Area)

  • 정충길;신형진;박민지;조형경;김성준
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.1-8
    • /
    • 2011
  • In this study, In order to evaluate reliable of MODIS GPP, the MODIS GPP and Flux tower measured GPP were compared to evaluate the use of method on 8 days composite MODIS GPP. The 2008 Flux data ($CO_2$ Flux and air temperature) measured in Seolmacheon watershed ($8.48\;km^2$) were used. The Flux tower GPP was estimated as the sum of $CO_2$ Flux and $R_{ec}$ (ecosystem respiration) by Lloyd and Taylor method (1994). The summer Monsoon period from June to August mostly contributed the underestimation of MODIS GPP by cloud contamination on MODIS pixels. The 2008 MODIS GPP and Flux tower GPP of the watershed were $1133.2\;g/m^2/year$ and $1464.3\;g/m^2/year$ respectively and the determination coefficient ($R^2$) after correction of cloud-originated errors was 0.74 (0.63 before correction). Even though effect of Cloud-Originated Errors was eliminated, Solar radiation and Temperature are affected at GPP. Measurement of correct GPP is difficult. But, If errors of MODIS GPP analyze on Cloud Moonsoon Climate in korea and eliminated effect of Cloud-Originated Errors, MODIS GPP will be considered GPP increasing of 9 %. There, Our results indicate that MODIS GPP show reliable and useful data except for summer period in Moonsoon Climate.