• Title/Summary/Keyword: Radiation benefits

Search Result 114, Processing Time 0.031 seconds

Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge (Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가)

  • Kang, Su-Man;Jang, Eun-Sun;Lee, Byung-Koo;Jung, Bong-Jae;Shin, Jung-Sub;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.343-349
    • /
    • 2012
  • Intensity Modulated Radiotherapy (IMRT) is increasing its use recently due to its benefits of minimizing the dose on surrounding normal organs and being able to target a high dose specifically to the tumor. The study aims to measure and evaluate the dose distribution according to its dynamic changes in Mapcheck. In order to verify the dose distribution by EDW angle($10^{\circ}$,$15^{\circ}$,$20^{\circ}$,$25^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$), field size (asymmetric field) and depth changes (1.5 cm, 5.0 cm) using IMRT in Clinac ix, a solid phantom was placed on the Mapcheck and 100MU was exposed by 6 MV, 10MV X-ray. Using a 6MV, 10MV energy, the percentage depth dose according to a dynamic changes at a maximum dose depth (1.5 cm) and at 5.0 cm depth showed the value difference of maximum 0.6%, less than 1%, which was calculated by a treatment program device considering the maximum dose depth at the center as 100%, the percentage depth dose was in the range between 2.4% and 7.2%. Also, the maximum value difference of a percentage depth dose was 4.1% in Y2-OUT direction, and 1.7% in Y1-IN direction. When treating a patient using a wedge, it is considered that using an enhanced dynamic wedge is effective to reduce the scattered dose which induces unnecessary dose to the surroundings. In particular, when treating a patient at clinic, a treatment must be performed considering that the wedge dose in a toe direction is higher than the dose in a heel direction.

Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI (PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석)

  • Kim, Jung Wook;Park, Se Yun;Jo, Young Jun;Park, Jong Yeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.25-28
    • /
    • 2012
  • Purpose : It is important to reduce radiation dose associated with computed tomography (CT) scanning to as low as reasonably achievable (ALARA). With Dose Modulation Technic, user select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. In this paper, we presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of Dose Modulation Technic depending on Body Mass Index(BMI). Materials and Methods : In this study, 149 patients were examined(The mean age : $58{\pm}12.4$ years old). Biograph True Point 40 (Siemens, USA) and Gemini TF 64 (Philips. Cleveland) were used for equipment. When we used Care Dose 4D (Siemens, USA) and D-dom (Philips, Cleveland), we measured dose reduction and Computed Tomography Dose Index (CTDI) depending on BMI. Then we analyze data using SPSS Ver.18. Results : When we used Care Dose 4D, p-value is considered statistically significant by groups with the result that we compared Care Dose 4D with D-dom. On the other hand, p-value isn't considered statistically significant by groups using D-dom. Conclusion : Dose modulation based on the projection angle didn't affect degree of obesity. And When using Care Dose 4D, dose reduction rate in the normal patients were higher than the obese. In this study, there are errors on somato type. So I think more research have to be done. Then application of Dose Modulation technic can help in maintaining acceptable image quality while reducing radiation dose by 20-60% in most instances.

  • PDF

High VPP Combination Chemotherapy for Advanced Non-Small Cell Lung Cancer (진행된 비소세포 폐암에 대한 High-VPP 복합화학요법의 효과)

  • Hong, Seok-Cheol;Han, Pyo-Seong;Lee, Jong-Jin;Cho, Hai-Jeong;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.367-377
    • /
    • 1993
  • Background: The benefits of combination chemotherapy in unresectable non-small cell lung cancer remain uncertain. But, according to the recent reports, the response rates of cisplatin-based polychemotherapy regimens are higher than those of single agent. Also, the response rates of high-dose cisplatin group are higher than those of low-dose cisplatin group. In attemp to answer the question whether treatments, combination chemotherapy (high VPP) and combination chemotherapy with radiation therapy, improve survival in advanced non-small cell lung cancer, we begin to study. Method: Thirty-five patients above stage III, diagnosed histologically as non-small cell lung cancer, were enrolled. Among them, nineteen received a combination chemotherapy consisting of VP-16 & high-dose cisplatin (100 $mg/m^2$) and/or radiation therapy. The other group (16 subjects) received no therapy. To investigate the differences of survival and response rates between two groups and the side effects related to therapy, we reviewed patients' records. Results: 1) The overall objective response rate was 47%(9/19) with one complete remission. 2) In patients who received polychemotherapy and radiation therapy, the response rate was 60%(6/10) with one complete remission and survival rates of 3 months, 6 months and 12 months were 100%, 70% and 40%. 3) In patients who received polychemotherapy, the response rate was 33% (3/9) with no complete remission and survival rates of 3 months, 6 months and 12 months were 78%, 67% and 33%. 4) Overall, treated patients survived significantly longer (p<0.05) than non-treated patients (median survival 307 days versus 95 days). 5) Analysis of the various prognostic factors disclosed that good performance status, stage III and squamous cell type showed the good response rates. 6) The toxicities were nausea and/or vomiting (100%), alopecia (90%), anemia (79%), leukopenia (69%), thrombocytopenia (2%), increased creatinine (16%) and neurotoxicity (5%). Conclusion: According to above results, there are relatively good results that high VPP combination chemotherapy in advanced non-small cell lung cancer improves survival in the treated group than in the non-treated group. Thus, it is considerd that we select the patients with proper indications and treat them with effective chemotherpy and radiation therapy. But, because improvement related to high VPP ploychemotherapy is not marked in this study, it is necessary that we should investigate follow-up studies in many cases.

  • PDF

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Comparison Study of Image Quality of Direct and Indirect Conversion Digital Mammography System (직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구)

  • Park, Hye-Suk;Oh, Yu-Na;Jo, Hee-Jeong;Kim, Sang-Tae;Choi, Yu-Na;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.239-245
    • /
    • 2010
  • The purpose of this study is to comprehensively compare and evaluate the characteristics of image quality for digital mammography systems which use a direct and indirect conversion detector. Three key metrics of image quality were evaluated for the direct and indirect conversion detector, the modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), which describe the resolution, noise, and signal to noise performance, respectively. DQE was calculated by using a edge phantom for MTF determination according to IEC 62220-1-2 regulation. The contrast to noise ratio (CNR) was evaluated according to guidelines offered by the Korean Institute for Accreditation of Medical Image (KIAMI). As a result, the higher MTF and DQE was measured with direct conversion detector compared to indirect conversion detector all over spatial frequency. When the average glandular dose (AGD) was the same, direct conversion detector showed higher CNR value. The direct conversion detector which has higher DQE value all over spatial frequency would provide the potential benefits for both improved image quality and lower patient dose in digital mammography system.

Video-Assisted Thoracic Surgery (VATS) (비디오 흉강경을 이용한 흉부수술에 대한 고찰)

  • Kim, Jin;Kim, Min-Ho;Kuh, Ja-Hong;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1143-1147
    • /
    • 1996
  • Video-assisted thoracic surgery(VATS) is emerging as a potentially less invasive means of managing a wide variety of thoracic disorders. VATS was performed in 46 cases, in the Department of Thoracic & Cardiovascular Surgery of Chonbuk national University Hospital from August 1992 to July 1995. There were 20 men and 26 women, whose age ranged from 14 to 56 years. They were diagnosed hyperhidrosis in 21 cases, mediastinal tumor in 12 cases, pneumothorax in· 10 cases, and one case each of lelomyoma of the esophagus, Raynaud's syndrome, Burger's disease. Operation time averaged 89.7 minutes, and no patient was converted to d thoracotomy. The number of troche used, period of chest tube drainage, and postoperative hospitalization were 3, 1.8 days, and 4.B days, respectively. The postoperative complication ocurred in 5 cases (remnant pneumothorax 1 case, phrenic nerve aralysis 1 case, persistant air leakage 2 cases, compensatory hyperhidrosis 1 case). One patient with persistent air leak was managed by thoracotomy on postoperative) days, and the other patient by chemical pleurodesis. One patient diagnosed pathologically as thymic carcinoma, was managed by radiation therapy. There was no postoperative death. VATS has the benefits of reduced postoperative pain and postoperative hospitalization, and good cutsmetic effect.

  • PDF

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

Research Trends in Hormetic Stimulation Effects of Herbicides in Plants (식물에서 제초제의 양면성 촉진반응 연구동향)

  • Pyon, Jong-Yeong;Uddin, Md. Romij;Kim, Sang-Woo;Park, Kee-Woong
    • Korean Journal of Weed Science
    • /
    • v.32 no.3
    • /
    • pp.159-169
    • /
    • 2012
  • Hormesis is a dose-response phenomenon that is characterized by low-dose stimulation and high-dose inhibition. This biphasic dose-responses have had a long and extensive history in the fields of chemical toxicology, radiation biology and pharmacology. Hormesis has been found from bacteria, fungi, plants and animals, but hormesis in plants has received relatively little attention. Thus principles, occurrence, factors affecting the expression of hormetic responses, and their mechanisms in plants induced by herbicides are reviewed to provide the potentials for crop enhancement. Bromacil, bromoxynil, chloramben, propachlor, terbacil, EPTC, MSMA, and glyphosate at low doses showed stimulatory response in growth. Subtoxic dose of glyphosate increased sucrose content in sugarcane that is used worldwide in sugarcane production. Low dose of protoporphyrinogen-inhibiting herbicides induced increased pathogen defence, and low dose of triazine herbicides improved nitrogen metabolism and increased protein content in some crops. Further researches on potential benefits and risks of hormesis and its mechanism are needed for application of crop enhancement in agriculture.

Three-Dimensional Printing Technology in Orthopedic Surgery (정형외과 영역에서의 삼차원 프린팅의 응용)

  • Choi, Seung-Won;Park, Kyung-Soon;Yoon, Taek-Rim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.103-116
    • /
    • 2021
  • The use of 3-dimensional (3D) printing is becoming more common, and its use is increasing in the orthopedic surgery. Currently, there are four major methods of using 3D printing technology in orthopedic surgery. First, surgical planning simulation using 3D printing model; second, patient-specific surgical instruments; third, production of customized prosthesis using 3D printing technique; fourth, patient-specific prosthesis produced by 3D printing. The areas of orthopedic surgery where 3D printing technology can be used are shoulder joint, spine, hip and pelvis, knee joints, ankle joint, and tumors. Since the diseases and characteristics handled by each area are different, the method of using 3D printing technology is also slightly different in each area. However, using 3D printing technology in all areas can increase the efficiency of surgery, shorten the surgery time, and reduce radiation exposure intraoperatively. 3D printing technology can be of great help in treating patients with particularly complex and difficult orthopedic diseases or fractures. Therefore, the orthopedic surgeon should make the most of the benefits of the 3D printing technology so that patient can be treated effectively.

The Usability Test of Manufactured Rounded Extension in Proton Therapy (자체 제작한 양성자 치료용 Rounded Extension의 유용성 평가)

  • Park, Ji-Yeon;Jang, Yo-Jong;Kang, Dong-Yun;Yeom, Du-Seok;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose: Long Extension (LE) is used in proton therapy for lung and abdomen. However, it has limitations in surface area, produces collision in posterior oblique beam which creates limitations in various gantry angles in planning therapy and increases air gap (distance between patient and compensator). Therefore, this study investigates the usability of manufactured Rounded Extension (RE) in comparison to LE to use the most suitable extension in proton therapy. Materials and Methods: To compare structural features of LE and RE. This study investigated usable gantry angle for snout sizes 100, 180 and 250 and CT scanned Humanoid phantom. And it compared the air gap in posterior oblique direction. Results: The structural features of two extensions are as follow. Because of the existence of supporting bar, the width of LE was 40 cm and RE was 50 cm. Result of the investigation of usable gantry angle for snout sizes 100, 180 and 250 are as follow. LE is ${\pm}36$ (average) at 180 degree and RE is ${\pm}70$ (average). And also, the air gap of RE is decreased by 11.3 cm in average at the same gantry angle. Conclusion: Manufactured RE for proton therapy has several benefits than LE. Its therapy surface area is wider and range of usable gantry angle is also wider. Also, the air gap at the posterior oblique beam has decreased. Therefore the usability of RE in proton therapy of lung and abdomen will be increased compared to LE. However, the air gap of proton therapy at the lateral direction may be increased, so there may be need for make up to decrease air gap at the lateral direction in the future.

  • PDF