• 제목/요약/키워드: Radiation Shielding Materials

검색결과 236건 처리시간 0.064초

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

고 에너지 전자선 치료를 위한 3D 프린터 물질의 차폐 성능평가 (Evaluation of Shielding Performance of 3D Printer Materials for High-energy Electron Radiation Therapy)

  • 오창우;배상일;문영민;양현경
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.687-695
    • /
    • 2022
  • 고 에너지 전자선 치료 시 차폐체로 사용되는 납을 대체할 수 있는 3D 프린터 소재를 찾기 위해 MCNP6 프로그램을 사용하였다. 고 에너지 전자선을 방출하는 선형가속기의 PDD(Percent Depth Dose), Flatness, Symmetry를 측정하고, MCNP6로 선형가속기를 모의 모사 후 비교하여 실측과 모의 모사와의 선원항이 일치함을 확인하였다. 납 차폐체를 모의 모사하여, 흡수선량의 95 % 이상을 차폐할 수 있는 납 차폐체의 적정 두께를 선정하였다. 3 mm 두께의 납 차폐체에 대한 흡수선량 데이터를 기준으로 하여 ABS + W(10%), ABS + Bi(10%), PLA + Fe(10%) 소재들의 1, 5, 10, 15 mm 두께 별로 모의 모사로 분석하여 차폐성능을 분석하였다. 3D 프린터로 각각의 시제품을 제작하여 모의 실험과 같은 조건으로 측정하여 분석한 결과 ABS+W(10%) 소재가 최소 10 mm 이상의 두께로 형성되었을 때, 3 mm 두께의 납을 대체할 수 있는 차폐성능을 가지는 것을 확인하였다. 주사전자현미경(SEM)과 EDS 스펙트럼을 이용하여 ABS + W(10%) 소재의 원소조성 및 표면형상을 분석하였다. 이러한 결과를 통해, 상용화 된 납 차폐체를 ABS + W(10%) 소재로 대체하면 납과 같은 차폐효과를 낼 뿐만 아니라 3D 프린터를 이용하여 환자 맞춤형으로 제작할 수 있어 고 에너지 전자선 치료에 매우 유용할 수 있음을 확인하였다.

Whole Abdomen CT촬영 시 차폐 재료에 따른 생식선 선량 감쇠 효과 (The Effects of Reducing a Dose on the Genital Gland at a CT Scan on the Whole Abdomen According to the Shielding Material)

  • 강은보;박철우
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.419-425
    • /
    • 2016
  • whole abdomen CT촬영에서 표재성 장기에 해당하는 생식선 부위의 선량을 줄이고 화질에 영향을 적게 주기 위한 차폐재를 제작하여 유용성을 확인하였다. 기존의 bismuth 재질과 비슷한 효과를 가지는 silicone 22 mm, aluminum 7.3 mm를 제작하였다. non shield, bismuth, silicone 22 mm, aluminum 7.3 mm 차폐재를 이용하여 생식선의 피폭 선량 감쇠, 영상의 CT number와 noise 변화, AAPM 팬텀에서 CT number, noise, uniformity를 측정하여 비교 실험하였다. 결과에서 bismuth 29.96%, silicone 22 mm 13.10%, aluminum 7.3 mm 18.27%로 피폭 선량이 감소되었다. 그러나 bismuth 재질의 경우 영상의 CT number 변화가 크고, AAPM 팬텀 영상검사 uniformity 항목에서 부적합으로 측정되어 생식선과 같은 표재성 장기에서 화질 변화가 큰 것으로 나타났다. 생식선과 같은 표재성 장기의 경우 silicone 22 mm, aluminum 7.3 mm의 차폐재를 사용한다면 화질 변화를 줄이면서 방사선 피폭을 줄이는데 도움이 될 것이라 판단된다.

몬테카를로 시뮬레이션을 이용한 차폐체 원소 평가 (A Study on the Shielding Element Using Monte Carlo Simulation)

  • 김기정;심재구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.269-274
    • /
    • 2017
  • 본 연구에서는 기존의 납을 대체할 수 있는 의료방사선 차폐시트 적용을 위해 몬테카를로 시뮬레이션을 이용하여 각각에 대한 원소별 차폐능을 모의 추정하였다. 원소들의 선정은 차폐성능이 큰 것으로 알려진 원자번호가 큰 원소와 금속원소를 중심으로 최근에는 다양한 복합재들이 차폐성능을 향상시킨다는 보고에 따라 경량화, 가공성, 활동성 등을 고려하여 21개 원소를 선정하였다. 몬테카를로 시뮬레이션 코드를 이용한 전산모사 투과도 실험으로 21개의 원소를 대상으로 시뮬레이션 하여 추정한 결과 납을 대체할 차폐물질로 적당한 원소의 투과율은 텅스텐(w) 98.82%, 가돌리늄(Gd) 92.96%, 주석(Sn) 86.87%, 인듐(In) 86.38%, 안티몬(Sb) 86.33%, 바륨(Ba) 78.51%로 평가되었으며, 각 원소별 차폐성능을 모의 추정한 결과 텅스텐과 금이 98.82%와 98.44%로 차폐율이 가장 높은 것으로 추정되었다. 경제성과 가공성을 고려할 때 위 원소를 화합한 물질로 차폐체를 만드는 것이 적절할 것으로 사료된다.

$R-{\theta}$ 좌표계에 의한 원자로 압력용기 차폐해석체계 개발 (Development of Shielding Analysis System for the Reactor Vessel by $R-{\theta}$ Coordinate Geometry)

  • 김하용;구본승;김교윤;이정찬;지성균
    • Journal of Radiation Protection and Research
    • /
    • 제30권1호
    • /
    • pp.39-44
    • /
    • 2005
  • 노심 및 원자로의 구조 및 구성 물질이 확정되어 있지 않은 개발단계의 신형원자로의 압력용기에 대한 $R-{\theta}$좌표에서 차폐해석을 수행하려면, 매번 선원항에 대한 모델작업을 하는데 많은 노력과 시간이 소요된다. 따라서 $R-\theta$좌표에 의한 반경방향의 원자로 압력용기에 대한 차폐해석에 있어서 노심의 기하학적 구조에 영향을 받지 않고 해석할 수 있는 체계를 개발하였다. 개발된 해석체계를 이용하여 육방형 노심배열을 갖는 일체형 원자로의 압력용기에 대한 차폐해석을 수행하여, 그 결과를 MCNP 해석결과와 비교 분석하였다. 분석결과 개발된 해석체계가 좀 더 보수적인 결과를 나타내었으며 이는 차폐해석측면에서 타당하다. 또한 이 해석체계를 개발함으로써 그 동안 수작업으로 작성하였던 노심내부에 대한 모델에 대한 오차를 줄일 수 있으며 이에 소요되는 시간 및 노력을 줄일 수 있을 것으로 판단된다.

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material

  • Mohammad W. Marashdeh;Fawzy H. Sallam;Ahmed M. Abd El-Aziz;Mohamed I. Elkhatib;Sitah f. Alanazi;Mamduh J. Aljaafreh;Mohannad Al-Hmoud;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2740-2747
    • /
    • 2024
  • The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ℃ for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm-1 (at 0.103 MeV), 0.304-0.338 cm-1 (at 0.662 MeV), and 0.160-0.178 cm-1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications.

방사성의약품 투여 시 피폭선량 저감에 대한 연구 (The Study of Radiation Reducing Method during Injection Radiopharmaceuticals)

  • 조석원;정석;박준영;오신현;남궁혁;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.80-85
    • /
    • 2012
  • 전신 골 스캔은 골친화성 방사성의약품으로 뼈의 생리적 변화를 영상화하는 검사방법으로, 140 keV의 감마선을 방출하는 방사성핵종이 표지된 방사성의약품을 주사 후 촬영하는 영상기법이다. 외부피폭으로부터 방사선방호의 3원칙은 시간, 거리, 차폐이다. 방사성의약품은 투여 시 개봉선원이 되기 때문에 방사선방호 원칙에 따라 피폭을 줄이기 위하여 빠른 시간 내에 주사하는 것이 좋다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없는 제한점이 있다. 본 연구는 방사성의약품으로부터 거리에 따른 피폭선량 변화를 확인하고, 차폐체를 사용 후 피폭량의 변화를 관찰하여 방사선 종사자의 피폭 관리에 도움이 되고자 한다. 방사성의약품 투여 시 소요되는 주사시간의 평균을 구하기 위하여 훈련된 주사 담당자가 환자에게 주사하는 시간을 총 50회 측정하였고, 그 평균값(약 2분)을 구하였다. 1 mL주사기에 옥시드로산테크네슘 925 MBq를 0.2 mL 로 맞춘 다음 50 cm, 100 cm, 150 cm, 200 cm에서 방사선 측정기(FH-40, Thermo Scientific, USA)로 선량을 측정하였다. 그리고 방사선차폐체(납 6 mm)를 선원으로부터 25 cm에 설치 한 후 50 cm 거리에서 선량을 측정하였다. 모든 선량측정은 각각 20회에 걸쳐 재현성을 검증하였다. 차폐 전과 차폐 후의 선량의 상관관계는 SPSS (ver. 18)을 사용하여 paired t-test로 검증하였다. 차폐체를 설치하지 않은 선원으로부터 거리에 따른 2분간 받는 피폭량은 50 cm에서 $1.986{\pm}0.052{\mu}Sv$, 100 cm에서 $0.515{\pm}0.022{\mu}Sv$, 150 cm에서 $0.251{\pm}0.012{\mu}Sv$, 200 cm에서 $0.148{\pm}0.006{\mu}Sv$로 나타났다. 차폐를 설치 후 측정 시 피폭량은 $0.035{\pm}0.003{\mu}Sv$로 차폐체 사용 전과 후의 피폭선량은 통계적으로 유의한 차이가 있는 것으로 나타났다($p$<0.001).전신 골스캔은 핵의학 검사에서 많은 비중을 차지하고 있기 때문에 방사성의약품 투여 시 피폭을 줄이기 위해서 외부피폭의 방어원칙을 적절히 병행하여 피폭 저감을 위해 노력해야 한다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없고, 환자의 혈관 확보가 어려운 경우 주사시간이 길어질 수 있다. 본 연구를 통해 거리가 멀어짐에 따라 피폭선량이 감소하는 것을 확인하였고, 선원으로부터25 cm 거리에 차폐체 설치 시 피폭선량이 감소하는 것을 확인할 수 있었다. 본 연구를 통해 방사성의약품 투여 시 차폐체를 사용함으로써 방사선 피폭 저감에 도움이 될 것으로 사료된다.

  • PDF

고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐 (Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy)

  • 추성실;서창옥;김귀언
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 의료용 선형가속기에서 발생되는 고 에너지 광자선은 콜리메이터에 의하여 누출되며 치료두부(head), 콜리메이터, 환자를 포함한 치료실내의 모든 벽과 구성 물질들에 의하여 많은 산란선이 발생된다. 방사선치료는 종양에 따라서 최소한 40 Gy에서 80 Gy까지 조사되기 때문에 주위건강조직 특히 생식가능한 사람에 대한 생식선의 피폭선량을 평가하여야하며 종양치료에 영향을 주지 않은 범위에서 가능한 방법을 동원하여 피폭선량을 줄여야한다. 방사선 안전관리등의 기술기준에 관한 규칙(과학기술부령 제17호) 제3절 의료분야의 특별기준, 제44조(진료환자의 방사선 피폭)에 의하면 진료를 위한 환자 피폭선량을 합리적으로 달성 가능한 최소의 수준으로 유지하기 위한 절차를 구비하여야 하며 과학기술부 장관은 이에 준하는 의료시설 및 장비취급의 기술기준을 정하고 고시하여야한다고 명시 되어있다. 고 에너지방사선은 악성종양환자들의 치료성과를 향상시키는 동시에 치료후 방사선에 의한 만성효과가 발생 될 수 있기 때문에 주선속의 다양한 산란선과 누출선의 선질변화와 선량을 측정하고 생식선과 같은 주요장기를 산란선으로부터 차폐할 수 있는 기구를 제작 사용함으로서 방사선 피폭선량을 최대한으로 감소시킬 수 있었다. 고 에너지 방사선은 의료용 선형가속기(CLINAC 2100C/D. 2100C. 600C)에서 발생시킨 4, 6, 10 MV x-ray와 코발트원격치료장치(ALCYON II)의 코발트선원에서 방출되는 1.25 MV의 감마선을 이용하였다. 선량측정은 폴리스틸렌과 인체팬텀(Rando)사용하였으며 측정기는 이온함, TLD 및 필름을 사용하였다. 고 에너지 방사선에 의한 산란선은 장치의 콜리메이터 뿐만 아니라 치료실 벽 인체내부등 모든 방향에서 방사됨으로 납 벽돌에 의한 차폐율측정은 많은 변수를 가졌으며 고환인 경우에는 3면이 모두 차폐되도록 항아리모양으로 제작하였다. 태아인 경우 태아가 위치하고 있는 골반위에 육교모양의 선반을 만들고 그 위에 납 벽돌을 장치하도록 고안하였다. Co-60 감마선, 4 MV x-선, 10 MV x-선에서 발생되는 누출선량과 산란선량에 의한 평균 피폭선량은 조사면 중심으로부터 10, 30, 60cm 거리에서 조사면내 최대선량에 대하여 각각 $10^{-2},\;10^{-3},\;10^{-4}$의 비율로 측정되었으며 거리에 따라 지수함수로 줄어들었다. 흉부에 국한된 종양을 10 MV x-ray, $12{\times}12 cm^2$ 조사면으로 치료하였을 때 자궁에 받는 피폭선량은 0.9 mGy/Gy이며 고환이 받는 피폭선량은 0.6 mGy/Gy 이었으며 체장과 신장은 각각 4.8 mGy/Gy 와 2.5 mGy/Gy이다 10 MV x-선, $14{\times}14cm^2$ 조사면 경계로부터 10 cm 밖에서 납벽돌의 반가층 두께는 약 9.0 mm 이였고 20cm 밖에서는 반가층 두께가 약 6.5 mm로 측정되었다. 복부에 위치한 악성종양을 60 Gy 조사하였을 경우 태아가 위치하고 있는 자궁의 피폭선량은 약 370 mGy이고 이곳을 10 mGy이하가 되도록 차폐하려면 약 6.2 cm두께의 납 벽돌을 자궁위에 장착하여야 하며 골반치료시 고환에 10 mGy이하가 되도록 차폐하려면 약 5 cm 두께의 납 항아리가 요구된다. 고 에너지 고 준위 방사선치료시 고환은 3면을 항아리모양으로 차폐할 수 있어 피폭선량을 상당히 줄일 수 있으며 자궁인 경우 체내에서 산란된 선량의 차폐는 불가능하였다.

격자-강화된 다기능 복합재 구조체의 방사차폐에 관한 연구 (A Study on Radiation Shielding for Grid-stiffened Multi-Functional Composite Structures)

  • 장태성;이주훈;서현석;현범석;김택영;서정기
    • 한국항공우주학회지
    • /
    • 제42권8호
    • /
    • pp.629-639
    • /
    • 2014
  • 강성이 우수하고, 경량으로 제작이 가능한 격자강화 복합재 구조체를 다기능 구조체의 기층구조로 적용함으로써, 전기전자회로를 용이하게 내장할 수 있으며 방사차폐 특성을 갖춘 다기능 구조체에 대한 설계 및 제작을 수행하였다. 피치계열 탄소섬유 복합재료의 적용을 통해 열전달특성을 향상시키고, 전자회로의 하우징 구조물이 없어도 우주방사환경에 충분한 내구성을 갖도록 경량 국부 강화 방사차폐 방법을 제안하고, 양성자 조사시험을 통하여 선택적 방사차폐의 효과를 검증하였다.