• Title/Summary/Keyword: Radiation Protection Product

Search Result 74, Processing Time 0.024 seconds

Assessing the Activity Concentration of Agricultural Products and the Public Ingestion Dose as Result of a Nuclear Accident

  • Keum, Dong-Kwon;Jeong, Hyojoon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.2
    • /
    • pp.39-49
    • /
    • 2018
  • Background: A model to assess the activity concentration of agricultural products and the public ingestion dose as result of a nuclear accident is necessarily required to manage the contaminated agricultural systems by the accident, or to estimate the effects of chronic exposure due to food ingestion at a Level 3 PSA. Materials and Methods: A dynamic compartment model, which is composed of three sub-modules, namely, an agricultural plant contamination assessment model, an animal product contamination assessment model, and an ingestion dose assessment model has been developed based on Korean farming characteristics such as the growth characteristics of rice and stockbreeding. Results and Discussion: The application study showed that the present model can predict well the characteristics of the activity concentration for agricultural products and ingestion dose depending on the deposition date. Conclusion: The present model is very useful to predict the radioactivity concentration of agricultural foodstuffs and public ingestion dose as consequence of a nuclear accident. Consequently, it is expected to be used effectively as a module for the ingestion dose calculation of the Korean agricultural contamination management system as well as the Level 3 PSA code, which is currently being developed.

Experimental Study of Leaching Phenomena of Cs-137 From a Cement Matrix Generated at PWR Plant (가압 경수로에서 생성된 시멘트 고화체로부터 Cs-137의 용출 현상의 실험적 연구)

  • Doh, Jeong-Yeul;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.91-103
    • /
    • 1986
  • Experimental study for the leaching behavior of Cs-137 was carried out using the simulated evaporator bottom product of PWR plant. The method of leach test proposed by the IAEA was partially modified using ANS method. The effect of various factors, i.e., sampling method, curing temperature, curing time, leachant temperature, vermiculite addition and volume-to-surface ratio, was considered in this experiment. Diffusion model in semi-infinite slab was in a good agreement with the data obtained from 4-weeks cured specimens. The effective diffusion coefficient of the specimens which were cured at the temperature of $24^{\circ}C$ for 4 weeks was found to be $1.20{\sim}1.47{\times}10^{-11}cm^2/sec$. With the experimentally obtained diffusion coefficient ($1.47{\times}10^{-11}cm^2/sec$), long-term prediction for the leaching of Cs-137 was carried out using finite-slab approximation. The estimated fraction of Cs-137 which remains in the environment is found to be less than 0.25 percent of initial amount after 100 years. About 25 years after the beginning of leaching, its fractional amount in the environment reachs the maximum value, 0.66 percent of initial amount.

  • PDF

SPF Evaluation and Safety of Sunscreen Products (자외선 차단 제품의 SPF 측정과 안전성)

  • 김종일;이병곤;고재숙
    • Proceedings of the SCSK Conference
    • /
    • 1992.09a
    • /
    • pp.5-26
    • /
    • 1992
  • Many methods of in vitro SPF evaluation have been developed in order to measure SPF of sunscreen products. In this study, we compared two spectrophotometric in vitro measurements using the skin cast made of Luviset CAP- $X^{R}$ resin and Transpor $e^{R}$ tape as substrate with two in vivo measurements using guinea pig and human. And we also observed the radiation reaching on the earth's surface in Seoul for one year and the change of the primary skin irritancy along the change of SPF value. According to the our research, the first, in vivo measurement using guinea pig had the close agreement with SPF measurement using human and showed the tendancy that guinea pig SPF was lower than human SPF. The second, there was the good relationship between in vitro SPF by using Transpor $e^{R}$ tape and in vivo SPF, and it is possible to predict human SPF from Protection Index(PI) by using tape. The third, it is thought that SPE 20 is reasonable value because of UV intensity in Seoul and the primary skin irritancy of higher SPF than 25. So we propose that it is important to distinguish the sunscreen product having higher than approximate 25 from the category of general cosmetics including lower SPF sunscreen product.oduct.

  • PDF

Effect of a Herb Mixture (HIM-I) on the Protection of the Hematopoietic-Immune System and Self-renewal Tissues against Radiation Damage (면역조혈계 및 재생조직의 방사선 손상에 대한 생약복합물(HIM-I)의 방호 효과)

  • Park, Hae-Ran;Kim, Sung-Ho;Yee, Sung-Tae;Byun, Myung-Woo;Jo, Sung-Kee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.5
    • /
    • pp.605-612
    • /
    • 2005
  • In previous studies, we evaluated the effect of the 6 energy-tonic or blood-building prescriptions of traditional oriental medicine, and observed that Si-Wu-Tang and Bu-Zhong-Yi-Qi-Tang showed high activity in the protection of the gastrointestinal and hematopoietic organs in irradiated mice. But any of these prescriptions did not show a high activity in the activation of the immune cells. We performed this study to design an herb mixture which protects the self-renewal tissues and also promotes recovery of the immune system against radiation damage. In order to meet all the requirements, we designed a new mixture of 3 edible herbs listed in Korean Food Code. The mixture of Angelim gigas radix, Cnidium officinale rhizoma and Paeonia japonica radix was decocted with hot water, and the activities of the water extract (HIM-I) were evaluated. HIM-1 stimulated the immune cells in a much higher extent than the traditional prescriptions, and promoted dramatically the growth of bone marrow stem cells in vitro. Also, HIM-1 protected digestive and hematopoietic organs against radiation as effectively as the 2 prescriptions, Si-Wu-Tang and Bu-Zhong-Yi-Qi-Tang. On the other hand, it showed high in vitro antioxidative activity that might be considered as a mechanism of the protective effects against radiation. Although the detailed mechanisms of those effects remain to be elucidated, these results indicated that HIM-I might be a useful agent for protection and recovery of body from various risk factor as well as radiation, especially since it is a relatively nontoxic natural product.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Radioprotective Potential of Panax ginseng: Current Status and Future Prospectives (고려인삼의 방사선 방어효과에 대한 연구현황과 전망)

  • Nam, Ki-Yeul;Park, Jong-Dae;Choi, Jae-Eul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.19 no.4
    • /
    • pp.287-299
    • /
    • 2011
  • Pharmacological effects of Panax ginseng have been demonstrated in cardiovascular system, endocrine secretion and immune system, together with antitumor, anti-stress and anti-oxidant activities. Modern scientific data show protective effect of ginseng against bone marrow cell death, increased survival rate of experimental animals, recovery of hematopoietic injury, immunopotentiation, reduction of damaged intestinal epithelial cells, inhibition of mutagenesis and effective protection against testicular damages, caused by radiation exposure. And also, ginseng acts in indirect fashion to protect radical processes by inhibition of initiation of free radical processes and thus reduces the radiation damages. The research has made much progress, but still insufficient to fully uncover the action mechanism of ginseng components on the molecule level. This review provides the usefulness of natural product, showing no toxic effects, as an radioprotective agent. Furthermore, the further clinical trials on radioprotection of ginseng need to be highly done to clarify its scientific application. The effective components of ginseng has been known as ginsenosides. Considering that each of these ginsenosides has pharmacological effect, it seems likely that non-saponin components might have radioprotective effects superior to those of ginsenosides, suggesting its active ingredients to be non-saponin series. These results also show that the combined effects of saponin and non-saponin components play an important role in the radioprotective effects of ginseng.

Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography (심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가)

  • Yong-In Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

Image quality-based dose optimization in pediatric cone-beam computed tomography: A pilot methodological study

  • Hak-Sun Kim;Yoon Joo Choi;Kug Jin Jeon;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.264-270
    • /
    • 2024
  • Purpose: This study aimed to propose a methodological approach for reducing the radiation dose in pediatric cone-beam computed tomography (CBCT), focusing exclusively on balancing image quality with dose optimization. Materials and Methods: The dose-area product (DAP) for exposure was reduced using copper-plate attenuation of an X-ray source. The thickness of copper (Cu) was increased from 0 to 2.2 mm, and 10 different DAP levels were used. The QUART DVT_AP phantom and pediatric radiologic dentiform were scanned under the respective DAP levels. The contrast-to-noise ratio (CNR), image homogeneity, and modulation transfer function (MTF) were analyzed using the QUART DVT_AP phantom. An expert evaluation (overall image grade, appropriateness of field of view, artifacts, noise, and resolution) was conducted using pediatric dentiform images. The critical DAP level was determined based on phantom and dentiform analysis results. Results: CNR and image homogeneity decreased as the DAP was reduced; however, there was an inflection point of image homogeneity at Cu 1.6 mm (DAP=138.00 mGy·cm2), where the value started increasing. The MTF showed constant values as the DAP decreased. The expert evaluation of overall image grades showed "no diagnostic value" for dentiform images with Cu 1.9-2.2 mm (DAP=78.00-103.33 mGy·cm2). The images with Cu 0-1.6 mm (DAP=138.00-1697.67mGy·cm2) had a "good," "moderate," or "poor but interpretable" grade. Conclusion: Reducing DAP beyond a 1.6-mm Cu thickness degraded CBCT image quality. Image homogeneity and clinical image grades indicated crucial decision points for DAP reduction in pediatric CBCT scans.

A Study on the Determination of Radionuclide Concentrations in Animal Feedstuffs for Use Following a Nuclear Emergency (원자력 비상시 가축의 사료로 이용을 위한 사료내 방사성 핵종농도 결정에 대한 연구)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Choi, Young-Gil;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.87-91
    • /
    • 2001
  • The optimized derived intervention levels for animal products were evaluated based on cost-benefit analysis. From these results, the radionuclide concentrations in animal feedstuffs for use were derived. It was shown that radionuclide concentrations in animal feedstuffs for use depend strongly on animal products, radionuclides and feeding period (period from the starting time to be led with contaminated feedstuffs to production time of animal products). In case of feedstuffs contaminated with long-lived radionuclides ($^{l37}Cs,\;^{90}Sr$), the feedstuffs with lower contamination should be supplied to animals with increase of feeding period due to the bioaccumulation of radionuclides. While, in case of feedstuffs contaminated with short-lived radionuclides ($^{131}I$), the feeding of higher contaminated feedstuffs was possible with increase of feeding period due to radionuclide decay. It was shown that $^{137}Cs$ concentration in animal feedstuffs lot use was lower than $^{90}Sr$ concentration. It is primarily, due to the higher feed-animal product transfer factor of $^{137}Cs$.

  • PDF

Estimation of In-plant Source Term Release Behaviors from Fukushima Daiichi Reactor Cores by Forward Method and Comparison with Reverse Method

  • Kim, Tae-Woon;Rhee, Bo-Wook;Song, Jin-Ho;Kim, Sung-Il;Ha, Kwang-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.114-129
    • /
    • 2017
  • Background: The purpose of this paper is to confirm the event timings and the magnitude of fission product aerosol release from the Fukushima accident. Over a few hundreds of technical papers have been published on the environmental impact of Fukushima Daiichi accident since the accident occurred on March 11, 2011. However, most of the research used reverse or inverse method based on the monitoring of activities in the remote places and only few papers attempted to estimate the release of fission products from individual reactor core or from individual spent fuel pool. Severe accident analysis code can be used to estimate the radioactive release from which reactor core and from which radionuclide the peaks in monitoring points can be generated. Materials and Methods: The basic material used for this study are the initial core inventory obtained from the report JAEA-Data/Code 2012-018 and the given accident scenarios provided by Japanese Government or Tokyo Electric Power Company (TEPCO) in official reports. In this research a forward method using severe accident progression code is used as it might be useful for justifying the results of reverse or inverse method or vice versa. Results and Discussion: The release timing and amounts to the environment are estimated for volatile radioactive fission products such as noble gases, cesium, iodine, and tellurium up to 184 hours (about 7.7 days) after earthquake occurs. The in-plant fission product behaviors and release characteristics to environment are estimated using the severe accident progression analysis code, MELCOR, for Fukushima Daiichi accident. These results are compared with other research results which are summarized in UNSCEAR 2013 Report and other technical papers. Also it may provide the physically based arguments for justifying or suspecting the rationale for the scenarios provided in open literature. Conclusion: The estimated results by MELCOR code simulation of this study indicate that the release amount of volatile fission products to environment from Units 1, 2, and 3 cores is well within the range estimated by the reverse or inverse method, which are summarized in UNSCEAR 2013 report. But this does not necessarily mean that these two approaches are consistent.