• Title/Summary/Keyword: Radiation Limits

Search Result 174, Processing Time 0.025 seconds

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Immune Protection Factor of Sunscreens in Humans is Dependent on Protection from UVA and Cannot be Predicted from the Sun Protection Factor

  • Halliday, Gary M.;Poon, Terence S.C.;Damian, Diona L.;Barnetson, Ross St.C.
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.236-239
    • /
    • 2002
  • Sunscreens have been advocated as an important means of preventing skin cancer. UV-induced immunosuppression is important for skin cancer development, yet the effectiveness of sunscreens in protecting the human immune system from UV radiation is unclear. The only currently accepted method of sunscreen rating is the Sun Protection Factor (SPF) based on prevention of erythema. We developed an in vivo non-invasive method for evaluating protection of the human immune system from UV radiation based on recall contact sensitivity to nickel, a common allergen. Using this system we showed that broad-spectrum sunscreens provide greater protection to the immune system than sunscreens which protect from UVB only. UVA was found to be immunosuppressive. We developed this technique to enable the study of solar simulated UV radiation dose responses and determined Immune Protection Factors (IPFs) for six commercially available sunscreens based on limits of protection from the dose response data. We found that the IPF did not correlate with the SPF and that protection from erythema therefore cannot be used to predict protection of the immune system. However, IPF was significantly correlated to the UVA protective capability of the sunscreens, indicating that sunscreen protection from UVA is important for prevention of immunosuppression. We recommend that sunscreens should be rated against their immune protective capability to provide a better indication of their ability to protect against skin cancer.

  • PDF

Protective Effects of Trithioformaldehyde against Radiation Damage of Mouse Jejunal Crypt Cells (TTFA의 마우스 공장 소낭선에 대한 방사선 방호작용)

  • Lee, Jong-Hwoa;Kwon, Jun-Tack;Cho, Byung-Heon
    • The Korean Journal of Pharmacology
    • /
    • v.24 no.2
    • /
    • pp.217-220
    • /
    • 1988
  • At present, the treatment of the radiation-induced diseases are only performing by the palliative treatment technique. Moreover, radioprotective drugs are a little toxic for human being and this seriously limits their application with various complication in clinical uses. Accordingly, new radioprotectors need developing. In our Lab., we synthesized trithioformaldehyde (TTFA), containing three sulfur atom, and examined the effect on mouse jejunal crypt cells after irradiation. Mice treated with TTF A (2.0 g/ kg) showed 78% survival ratio at 30 day after 800 rad irradiation. 1.0 g/kg and 2.0 g/kg of TTF A increased resistance of jejunal crypt cells to single doses of radiation by protection factors of 1.17 and 1.23, respectively.

  • PDF

Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

  • Jeong, Jongtae;Baik, Min Hoon;Kang, Mun Ja;Ahn, Hong-Joo;Hwang, Doo-Seong;Hong, Dae Seok;Jeong, Yong-Hwan;Kim, Kyungsu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1368-1375
    • /
    • 2016
  • A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incidentfree (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

BLACK HOLE-IGM FEEDBACK, AND LINKS TO IGM FIELDS AND CR'S

  • KRONBER PHILIPP P.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.501-507
    • /
    • 2004
  • The uniquely large dimensions of Giant radio galaxies (GRGs) make it possible to probe for stringent limits on total energy content, Faraday rotation, Alfven speeds, particle transport and radiation loss times. All of these quantities are more stringently limited or specified for GRG's than in more 'normal' FRII radio sources. I discuss how both global and detailed analyses of GRG's lead to constraints on the CR electron acceleration mechanisms in GRG's and by extension in all FRII radio sources. The properties of GRG's appear to rule out large scale Fermi-type shock acceleration. The plasma parameters in these systems set up conditions that are favorable for magnetic reconnection, or some other very efficient process of conversion of magnetic to particle energy. We conclude that whatever mechanism operates in GRG's is probably the primary extragalactic CR acceleration mechanism in the Universe.

A 2.4 GHz 802.11b Throughput Estimation In a Noisy Environment Using an Experimental Noise Parameter

  • Hur Min-Ho;Lim Sung-Jin;Kwon Sewoong;Yoon Young-Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2005
  • In this paper, a numerical permissible disturbance model is proposed to preserve a throughput performance of a 2.4 GHz wireless LAN service. The model is composed of two parameters, a peak value and a time rate of noise signal. The model parameters are experimentally determined from an APD parameter measurement. The APD parameter is measured by using the APD measurement method which is recommended from CISPR/A/447/CD.

THREE-DIMENSIONAL INFINITE ELEMENTS FOR WAVE FORCE EVALUATION ON OFFSHORE STRUCTURES (해양구조물의 파력산정을 위한 3-차원 무한요소)

  • Park, Woo-Sun;Yoon, Chung-Bang;Pyun, Chong-Kun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.04a
    • /
    • pp.8-14
    • /
    • 1991
  • The finite element technique incorporating infinite elements is applied to analyzing the general three dimensional wave-structure interaction problems within the limits of linear wave theory. The hydrodynamic farces are assumed to be inertially dominated, and viscous effects are neglected. In order to analyze the corresponding boundary value problems efficiently, two types of elements are developed. One is the infinite element for modeling the radiation condition at infinity, and the other is the fictitious bottom boundary element for the case of deep water. To validate those elements, numerical analyses are performed for several floating structures. Comparisons with the results from culler available solution methods show that the present method incorporating tile infinite and the fictitious bottom boundary elements gives good results.

  • PDF

HOW TO MONITOR AGN INTRA-DAY VARIABILITY AT 230GHZ

  • Kim, Jae-Young;Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • We probe the feasibility of high-frequency radio observations of very rapid flux variations in compact active galactic nuclei (AGN). Our study assumes observations at 230GHz with a small 6-meter class observatory, using the SNU Radio Astronomical Observatory (SRAO) as an example. We find that 33 radio-bright sources are observable with signal-to-noise ratios larger than ten. We derive statistical detection limits via exhaustive Monte Carlo simulations assuming (a) periodic, and (b) episodic flaring flux variations on time-scales as small as tens of minutes. We conclude that a wide range of flux variations is observable. This makes high-frequency radio observations-even with small observatories-a powerful probe of AGN intra-day variability; especially, those which complement observations at lower radio frequencies with larger observatories like the Korean VLBI Network (KVN).