• 제목/요약/키워드: Radiation Limits

검색결과 174건 처리시간 0.029초

Visual Sample Plan을 활용한 미신고 시설 핵활동 분석 시료 채취 계획 (Soil sampling plan for Analysis of Nuclear Facility Activities utilizing Visual Sample Plan)

  • 박수희;한지영;박제완;김용민
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.15-21
    • /
    • 2024
  • The Non-Proliferation Treaty (NPT) is the basis of global efforts to prevent the spread of nuclear weapons. In Republic of Korea, safety measures are integrated with NPT approval through agreements with the International Atomic Energy Agency (IAEA) and the Safeguards Agreement. In contrast, Democratic People's Republic of Korea (DPRK), initially an NPT member, withdrew, refusing IAEA nuclear inspections. This inhibits the precise management of DPRK's nuclear facilities and limits access to related information. The Korean Peninsula, politically divided, sees DPRK in control of nuclear weapons. Although the IAEA periodically evaluates DPRK's nuclear facilities, there's a research gap in contamination and site management with nuclear activities. Recognizing the presence or absence of such activities is crucial for peaceful nuclear endeavors. This proposal suggests the number and locations for environmental sample collection using the Visual Sample Plan (VSP) software for nuclear activity analysis. VSP software is sample collection locations and quantities through statistical tests on collected data, ensuring reliability for decision-making. The proposal identifies sites and facilities for nuclear activity analysis based on IAEA safety reports, utilizing the software's embedded methods. Suggested sampling locations for undisclosed nuclear activities employ VSP's embedded techniques, including 'Show that at least some high % of the sampling area is acceptable' to confirm contamination and 'Estimate the Mean' to evaluate the average contamination level.

방사선사(放射線士) 교육(敎育)의 임상실습(臨床實習) 개선(改善)에 관(關)한 연구(硏究) (A Study of the Improvement of Clinical and Practical Trainings in the Education of Radiologic Technologists)

  • 이만구;강세식;윤한식;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제6권1호
    • /
    • pp.117-129
    • /
    • 1983
  • This study, in order to improve clinical and practical trainings in the education of radiologic technologists, applies to 76 medical institutions of 91 ones which are used as the hospitals of clinical and practical training in 9 existing junior colleges except 3 new ones of 12 ones throughout all over the country from November 1, in 1982 to April 30, in 1983. And the purpose of this study is to research the percent conditions of basic practical trainings and clinical ones enforced in each college, and the percent conditions, equipments, contents, and opinions in clinical and practical trainings enforced in each hospital. The results are summarized as follows; 1. In the case of junior colleges in the whole country the curriculum of basic practical trainings averages 336.66 hours and the limits are between 120 and 510 hours. The actual hours in practice average 140 hours and the limits are between 60 and 240 hours, which correspond to 41.58% of the curriculum of basic practical trainings. 2. There were three junior colleges among nine that had a reserved hospital for clinical and practical trainings(only 33.33%). 3. The period of the practice was almost vacation in 4 junior colleges. The practice was conducted only for students to want the practice(44.45%), junior colleges that all students in them conducted the practice was 2 junior colleges and presented 22.22%. 4. In the field of students engaging in the practice, each field of radiation therapy and nuclear medicine presented 16.5%, 20.3% and almost students didin't have experience for the practice. 5. In medical institutions the educational institutions for intern showed 67.11%. Hospital with radiologist showed 26.32%. Radiotechnologist who had experience below 5 years presented 60.17%. 6. In the equipment for radiation diagnosis, each hospital had no difference. The number of hospitals passessing diagnostic equipments above 125 KVP was 56.26%. But radiation therapy equipment and nuclear medicine equipment had extremely low rate. 7. In the diagnosis of patient in the practice hospital, conventional radiography-to Skull, Chest, Abdomen, Skeleton, Urogenital system-reached the criterion. But special radiography was comparatively low. There appeared low rate, 32.89% in the field of nuclear medicine, 15.79% in the field of radiation therapy. 8. Students who carried out the practice were 1-89 students, days in practice were 1-30 days. There were differences in that point among among hospitals. Junior colleges conducting the practice were 2 colleges per hospital. Scope of the object were 1-8 junior colleges. 9. The practice conducted for the request of the colleges presented 72.37%, in addition, The prctices were conducted for growth of the younger generation and the same coperation with the colleges establishment of sisterhood with the colleges, relationship with students. 10. The practice conducted without the establishment of plan presented 59.21% The need for guiding book to the practice and evaluating was recognized over 90%. 11. In the relation between the practice with achievement of credit. There were big differences in opinion between hospitals-Group and the colleges-Group; hospital-Group had opinion that must follow achievement of credit with the practice. The colleges-Group had opinion that must conduct the practice after achieving credit. 12. After conducting the practice, in the practice leaders satisfaction degree dissatisfactory opinion presented the most rate 80.26%. Very much satisfactory opinion, as one hospital, presentd only 1.32%. 13. Both hospitals-Group and the colleges-Group had an opinion that the practice leader must have actual experiences, lectures and achievement, an opinion that actual experiences is over 5 years. 14. In the guide of human relation, cooperation, responsibility, courtesy to patients. Both hospitals-Group and the colleges-Group had an opinion that the guide must be involved in the period of the practice and must be instructed.

  • PDF

Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리 (Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy)

  • 심수정;심장보;이상훈;민철기;조광환;신동오;최진호;박성일;조삼주
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.33-41
    • /
    • 2012
  • 최근 환자맞춤형방사선치료를 위해 임상에서 활용하고 있는 입체적세기조절회전방사선치료의 정도관리를 수행하고자 기존의 세기조절방사선치료에서 수행하는 정도관리 프로그램을 본 원의 실정에 맞게 치료계획단계 정도관리(Treatment planning QA), 치료전 전달단계 정도관리(Pretreatment delivery QA), 치료단계 정도관리(Treatment QA)인 세 가지 단계로 나누어 설정하였다. 각 정도관리 단계에서는 정도관리 프로그램에 따라 점검할 항목과 측정하여 평가할 항목을 설정하여 문서화를 위해 서식화 하였다. 본 원에서는 서식화한 정도관리 프로그램에 따라 실제 치료환자에 적용하였으며 본원의 치료전 전달 정도관리의 임상 허용기준을 위해 국소적 신뢰수준(confidence limit, CL)을 평가하였다. 그 결과 고선량 영역 점선량 측정, 저선량영역 점선량 측정의 CL는 모두 기존의 IMRT 수준과 유사한 결과를 얻었으며 이를 토대로 본원의 임상허용 기준은 고선량영역은 3%, 저선량 영역은 5%로 설정하였다. 입체적세기조절회전방사선치료의 특성상 Intensity map 평가는 360도 전 방향에서 Intensity map을 측정할 수 있는 ArcCheck 기기를 사용 하여 감마 지표(Gamma Index) 평가를 하였으며 그 결과는 IMRT의 개별적 intensity map 평가와 유사한 결과를 얻었으며 본원의 CL은 93%로 설정하였다. 등선량분포 평가는 2D detector array인 Mapcheck을 사용하였으며 95% 이상의 일치도를 보여 본원의 CL은 95%로 설정하였다. 방사선치료 정도관리에서 임의의 불확도와 계통 오차를 줄이려면 실제 환자 적용에 앞서 다 기관이 참여하는 팬톰을 이용한 국소적 CL 평가를 권장하고 있다. 국내 여건상 다 기관이 참여하는 연구가 여의치 않다면 본 연구와 같이 개별 기관에서 자체적으로 허용검사가 끝난 후에 실제 임상에서는 환자 치료 부위별로 세분화 하여 국소적 CL을 평가하는 방법이 유용할 것으로 사료된다.

전폐형 유도전동기 엔드와인딩 표면의 열전달에 미치는 회전자팬의 영향 (Rotor fan effects on end winding heat transfer in totally enclosed fan cooled induction motor)

  • 윤명근;고상근
    • 대한기계학회논문집B
    • /
    • 제21권7호
    • /
    • pp.928-938
    • /
    • 1997
  • The end winding is an important part in induction motor for thermal analysis. But there is little information on the heat transfer coefficient of that surfaces because of geometrical complexity. So our experimental object is to know the heat transfer coefficient of end winding and find the optimum design parameter of rotor fan. Carbon coated papers were used for a uniform heat generating surfaces which were easy to fabricate. The experiments of some parameters were performed as varying rotation speed of rotor fan. We obtained the local and average Nusselt number of the end winding surfaces by correcting radiation and conduction losses errors. The results showed that the average Nusselt number increased with rotor fan blade number and width but decreased with end winding length. However, the increasing limits existed in the case of rotor fan width and blade number. So optimum design value were obtained for rotor fan width and blade numbers.

THE QUEST FOR COSMIC RAY PROTONS IN GALAXY CLUSTERS

  • PFROMMER C.;ENSSLIN T. A.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.455-460
    • /
    • 2004
  • There have been many speculations about the presence of cosmic ray protons (CRps) in galaxy clusters over the past two decades. However, no direct evidence such as the characteristic $\gamma$-ray signature of decaying pions has been found so far. These pions would be a direct tracer of hadronic CRp interactions with the ambient thermal gas also yielding observable synchrotron and inverse Compton emission by additionally produced secondary electrons. The obvious question concerns the type of galaxy clusters most likely to yield a signal: Particularly suited sites should be cluster cooling cores due to their high gas and magnetic energy densities. We studied a nearby sample of clusters evincing cooling cores in order to place stringent limits on the cluster CRp population by using non-detections of EGRET. In this context, we examined the possibility of a hadronic origin of Coma-sized radio halos as well as radio mini-halos. Especially for mini-halos, strong clues are provided by the very plausible small amount of required CRp energy density and a matching radio profile. Introducing the hadronic minimum energy criterion, we show that the energetically favored CRp energy density is constrained to $2\%{\pm}1\%$ of the thermal energy density in Perseus. We also studied the CRp population within the cooling core region of Virgo using the TeV $\gamma$-ray detection of M 87 by HEGRA. Both the expected radial $\gamma$-ray profile and the required amount of CRp support this hadronic scenario.

Xenon in molten salt reactors: The effects of solubility, circulating particulate, ionization, and the sensitivity of the circulating void fraction

  • Price, Terry J.;Chvala, Ondrej;Taylor, Zack
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1131-1136
    • /
    • 2020
  • Xenon behaves differently in molten salt reactors (MSRs) compared to solid fuel reactors. This behavior needs exploring due to the large reactivity effect of the 135Xe isotope, given the current interest in MSR power plant development for commercial deployment. This paper focuses on select topics in xenon transport, reviews relevant past works, and proposes specific research questions to advance the state of the art in each of the focus areas. Specifically, the paper discusses the issue of xenon solubility in MSRs, the behavior of particulates circulating in MSR fuel salt and its influence on the xenon transport, the possibility of ionization of xenon atoms which changes its effective size and thus affects its mass transport, and finally the issue of circulating void fraction and how it is measured. This work presents specific recommendations for MSR designers to research the limits of Henry's law validity, circulating particulate scrubbers, validity of mass transport coefficients in high radiation fields, and the effects of pump speed on circulating void fraction.

팬과 히트 싱크를 이용한 LED 전조등의 냉각성능 해석 (Cooling Performance of LED Head Lamp with Heat Sink and Cooling Fan)

  • 고만석;이주한;오상준;조현석;서태범
    • 대한기계학회논문집B
    • /
    • 제33권12호
    • /
    • pp.947-951
    • /
    • 2009
  • LED has the merits of high reliability, semi-permanent life, rapid-response and its small size for use as light source of head lamp. But the dependence of its performance and life on temperature affect on its practical use. Which dependence makes problem when the LED is heated up to a higher temperature level by self-generation of heat, due to "highly integration" to get enough quantity of light. To solve this problem, effective cooling system is needed that consider conduction, convection and radiation. This study points out the limits of natural convection cooling system and propose of forced convection with heat sink. Also, it describes a correlation between heat sink area and fluid velocity using numerical analysis to optimize the cooling system.

Multiplex PCR Detection of Waterborne Intestinal Protozoa: Microsporidia, Cyclospora, and Cryptosporidium

  • Lee, Seung-Hyun;Joung, Mi-Gyo;Yoon, Se-Joung;Choi, Kyoung-Jin;Park, Woo-Yoon;Yu, Jae-Ran
    • Parasites, Hosts and Diseases
    • /
    • 제48권4호
    • /
    • pp.297-301
    • /
    • 2010
  • Recently, emerging waterbome protozoa, such as microsporidia, Cyclospora, and Cryptosporidium, have become a challenge to human health worldwide. Rapid, simple, and economical detection methods for these major waterborne protozoa in environmental and clinical samples are necessary to control infection and improve public health. In the present study, we developed a multiplex PCR test that is able to detect all these 3 major waterborne protozoa at the same time. Detection limits of the multiplex PCR method ranged from $10^1$ to $10^2$ oocysts or spores. The primers for microsporidia or Cryptosporidium used in this study can detect both Enterocytozoon bieneusi and Encephalitozoon intestinalis, or both Cryptosporidium hominis and Cryptosporidium paNum, respectively. Restriction enzyme digestion of PCR products with BsaBI or BsiEI makes it possible to distinguish the 2 species of microsporidia or Cryptosporidium, respectively. This simple, rapid, and cost-effective multiplex PCR method will be useful for detecting outbreaks or sporadic cases of waterborne protozoa infections.

Smoothness of the Zodiacal Light and Emission from the AKARI North Ecliptic Pole Monito rObservations

  • Pyo, Jeong-Hyun;Matsumoto, Toshio;Tange, Tsutomu;Jeong, Woong-Seob;Matsuhara, Hideo;Matsuura, Shuji;Wada, Takehiko;Seo, Hyun-Jong;Hong, Seung-Soo
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.52.1-52.1
    • /
    • 2010
  • The Japanese infrared (IR) space mission AKARI monitored the brightness in the fields very close to the north ecliptic pole (NEP) with nine wavebands in Infrared Camera (IRC), which cover the wavelength range from 2 to $24{\mu}m$. We reduced the NEP monitor observations and examined the smoothness of the sky background brightness. Our analysis shows that the background brightness is smooth over a frame of about $10'\times10'$ within about 0.1% deviation in mid-IR. Because the zodiacal light (ZL) and emission (ZE) dominate the diffuse sky brightness in the near- and mid-IR wavelengths, the background brightness varies with season through a year. We tried sinusoidal fittings to the observed NEP background brightness. The fitting analysis shows that the sine function is successful in describing the seasonal variation of the ZL and ZE within 2% deviations from the observed brightness, especially for the 15, 18, and $24{\mu}m$ bands, within 0.3%. These results will provide limits and caveats for the studies of the cosmic infrared background radiation.

  • PDF

원전주변 지역 식물의 방사능 오탁에 관한 연구 - 해송과 아왜나무를 대상으로 - (Study on Radioactive Contamination of Plant Nearby Nuclear Power Plant - Focused on Pinus thunbergii Parl. and Viburnum awabuki K. KOCH -)

  • 강태호;조홍하;정진욱;국성도
    • 한국환경복원기술학회지
    • /
    • 제16권3호
    • /
    • pp.55-62
    • /
    • 2013
  • Generally, the radioactivity from NPP(Nuclear Power Plants) operation can be released below 3% of DRLs(Derived Release Limits) to environment. It was tried to understand which plant was efficient for absorbing radioactivity in this study. Pinus thunbergii Parl. and Viburnum awabuki K. KOCH were analyzed for radioisotope absorption. The samples were collected at three different locations depending on the distance from NPP at the vicinity 10km away, and 30km away. Gamma radionuclide was not detected from the samples, which means that the direct transition into the plant was not significant. Meanwhile, the very low level of radioactive tritium was detected in the samples. One remark was that every plant has different ability for tritium absorption. These results are expected to be applied to propagation and transplanting in radioactively contaminated area or reducing radioactivity in the soil and water near the plants.