• 제목/요약/키워드: Radiation Leakage

검색결과 206건 처리시간 0.024초

댐체 물성 평가를 위한 S파 반사법에 관한 연구 (A Study on S-wave Reflection method for the assessment of physical property of dam body)

  • 김형수;김중열;하익수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.392-399
    • /
    • 2005
  • Shear modulus (or rigidity) of dam material is an important parameter which can be directly associated with the deformation of dam. Seepage or leakage of water can cause the defects or cracks of dam body. The existence of cracks and rigidity of dam body are decisive information for the estimation of dam safety. Rigidity of material is mainly determined from S-wave velocity and the defects of dam body can be detected by seismic reflection survey. Therefore, seismic reflection survey will be a desirable method which can give a solution about dam safety problem. Among various physical properties of dam body, S-wave velocity is the most important information but it is not easy to get the information. In this study, diverse measuring techniques of S-wave reflection survey were attempted to get the information about S-wave velocity of dam body. Ultimately, S-wave velocity could be estimated by the analysis of SH reflection events which can be easily observed in shot gather data obtained from SH measuring technique. Meanwhile, P-wave reflection survey was also performed at the same profile. P-beam radiation technique which can reduce the surface waves and reinforce the P-wave reflection events was applied for giving a help to analyse P-wave velocity. In the end, P-and S-wave velocity, Vs/Vp, Poisson's ratio distribution of the vertical section under the profile could be acquired.

  • PDF

PILOT LNG저장탱크의 화재안전성 평가에 관한 연구 (Study on the Fire Safety Estimation for a Pilot LNG Storage Tank)

  • 고재선;김효
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.57-73
    • /
    • 2004
  • Pilot LNG Tank에서 LNG가 누출되어 화재가 발생할 경우의 정량적 안전성 평가를 고장수목법을 이용하여 4가지 형태의 주요 시나리오를 도출하고 이에 대한 분석을 수행하였다. 첫째 방출관에서 누출할 경우에 특정 Low Flammable Limit(LFL)반경은 형성하지 않았으며, 둘째는 탱크파손으로 인한 LNG 유출이라는 최악의 시나리오 분석을 수행하였고, 그 결과를 살펴보면 총 누출량이 같더라도 시간에 따라 여러 가지 확산범위가 나타남을 확인할 수 있었다. 셋째는 inlet/outlet파이프의 손상으로 인한 누출로 10달과 타분 두 경우에 대해 분석하였으나, 각각의 경우 LFL의 반경은 큰 차이를 보이지 않았다. 따라서, 이와 같은 LNG누출 사고의 경우 초기 방출량의 크기가 확산의 주요 인자임을 알 수 있었다. 넷째는 방류둑에서 LNG배관이 파손될 경우 LFL의 크기를 산출하였다. 한편 복사열 및 불꽃의 크기에 대한 피해결과 분석을 동시에 수행하였다.

비파괴 검사 시스템의 융합 적용 사례 (The Convergence Application Example of Non-destructive Inspection System)

  • 이정익
    • 한국융합학회논문지
    • /
    • 제8권3호
    • /
    • pp.191-197
    • /
    • 2017
  • 본 개발은 중간 크기 미만의 외형 결함을 검출함에 있어 X-Ray 광원을 사용하는 비파괴 장비이다. 본 연구개발물의 차별성은 X-Ray광원을 이용 중소형 생산제품들의 외부결함 유무를 실시간 검사할 수 있으며 표면 방사선 누설선량에 있으면서 검사 속도제어가 가능하다. 이를 소프트웨어로 해결하였다. 또한 작업 중 작업자 안전을 위해 도어 차단이 가능하고 동시에 장비 내부 구동 영상의 획인이 가능하다는 점이다. 이런 원리로 현재는 중소형 부품에서부터 크게는 컨테이너와 같은 검사시스템의 기반 기술로 활용이 가능하다. 본 연구는 자동차 산업 외에 다른 다양한 비파괴 시장 산업에 큰 영향을 미칠 것이다. 마지막으로 개발된 비파괴 장비는 $0.2Sv{\mu}$ 하에서 제어된다는 사실은 아주 중요한 사실이다.

부분적으로 물에 잠긴 백에 작용하는 유체역학적 힘 (On the Hydrodynamic Forces acting on a Partially Submerged Bag)

  • 이경중
    • 대한조선학회논문집
    • /
    • 제29권4호
    • /
    • pp.104-113
    • /
    • 1992
  • 압력이 차 있는 백이 물에 부분적으로 잠겨서 동요하고 있을 때의 유체역학적 문제가 다루어졌다. 쌍동형 공기부양선(SES)의 선미에는 공기의 유출을 막기위해 공기압이 채워진 백을 설치하고 있는데, 백에 의한 힘이 종동요에 큰 영향을 미친다. 백의 모양은 안과 밖의 압력차에 의해서 결정되므로, 유체동압력을 구하면 백의 모양을 알 수 있는데, 백의 모양변화를 알아야지만 유체동압력을 구할 수가 있다. 따라서 백 표면에서의 경계조건의 형태는 자유표면 경계와 더불어서 움직이는 경계가 된다. 본 논문에서는 이 문제를 정식화하고 선형화를 하였다. 또한 백이 동요할 때의 방사문제에 대한 계산예를, 백을 강체로 가정했을 때의 비교하여, 보여주고 있다. 여러가지의 백내의 압력값, 또 물에 잠긴 깊이에 대해서 계산이 이루어졌다.

  • PDF

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • 최치원;강상식;조성호;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

유리공장이식편을 이용한 인두 및 경부식도 재건술 (Pharyngoesophageal Reconstruction Using Free Jejunal Graft)

  • 김효윤
    • Journal of Chest Surgery
    • /
    • 제27권2호
    • /
    • pp.140-147
    • /
    • 1994
  • Reconstruction of the pharynx and cervical esophagus presents a tremendous challenges to surgeons. Over the past 2 years[1990, Dec.-1993, Jun], the free jejunal graft has been performed in 17 cases in Korea Cancer Center Hospital.The indications of this procedures were almost malignant neoplasms involving neck and upper aero-digestive tract; Hypopharyngeal cancer[12 cases, including 2 recurrent cases], laryngeal cancer[2 cases], thyroid cancer[2 cases, including 1 recurrent case], cervical esophageal cancer[1 case]. There were fifteen men and two women, and the mean age was 59.6 years. The anastomosis site of jejunal artery were common carotid artery[16 cases] or external carotid artery[1 case] and that of jejunal vein were internal jegular [15 cases] or facial[1 case] and superior thyroid vein[1 case]. The length of jejunal graft was from 9 cm to 17 cm[mean 13 cm] and the mean ischemic time was 68 minutes. There was one hospital mortality which was irrelevant to procedures[variceal bleeding] and one graft failure[1/16]. Other postoperative complications were neck bleeding or hematoma[3 cases], abdominal wound infection or disruption[5 cases], anastomosis site leakage[1 case], pneumonia[2 cases], graft vein thrombosis[1 case], and food aspiration[1 case]. The function of conduit was excellent and ingestion of food was possible in nearly all cases. Postoperative adjuvant radiation therapy was also applicable without problem in 7 cases. During follow-up periods, the anastomosis site stenosis developed in four patients, and the tracheal stoma was narrowed in one case but easily overcome with dilation. In conclusion, we think that the free jejunal graft is one of the excellent reconstruction methods of upper digestive tract, especially after radical resection of malignant neoplasm in neck with a high success rate and low mortality and morbidity rate.

  • PDF

IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증 (Verification of Clinical Usefulness of Jaw Tracking in IMRT)

  • 김진영;김기환
    • 한국방사선학회논문지
    • /
    • 제14권2호
    • /
    • pp.105-109
    • /
    • 2020
  • 세기조절방사선치료(IMRT)는 치료범위의 선량분포를 향상시키고 주변 정상조직을 보호한다는 점에서 두경부, 전립선, 뇌와 같은 부위에 널리 사용되고 있다. 그러나 이러한 세기조절방사선치료는 입체조형방사선치료에 비해 많은 방사선조사량으로 인해 누적선량이 증가하고 다엽콜리메이터의 누설선량이나 투과선량으로 인한 저선량이 증가하는 양상을 보인다. 이러한 누적선량이나 저선량의 증가는 악성 종양의 재발생율을 증가시키는 것으로 보고되고 있다. 본 논문에서는 뇌종양의 방사선치료에 있어 기존 선형가속기의 단점을 보완하고 다엽콜리메이터의 누설선량이나 투과선량을 줄이기 위해 개발된 Varian사의 TRUEBEAM 의 Jaw Tracking 기능의 임상적인 유용성을 검증하고자 하였다. Jaw tracking 기능의 임상적 유용성을 검증하기 위해 Varian사의 Eclipse11을 이용하여 치료범위에서 1) Organ At Risk(OAR)에 2 cm 이상 떨어진 경우 2) OAR에 2 cm 이하로 떨어진 경우 3) OAR를 포함하는 경우 3 가지의 원본 치료계획을 만들고 이를 복사한 후, Smart LMC Version 11.0.31을 이용하여 Jaw tracking 기능을 사용한 치료계획을 만들었다. 비교는 두 치료계획 간의 Cumulative Dose Volume Histogram(DVH) 에서 OAR의 평균선량 및 최대선량의 차이를 통해 평가하였다. 두 치료계획 간의 DVH 비교 결과 PTV가 OAR에 2 cm 이상 떨어진 경우 두 치료계획 간의 차는 최대 0.5 % 차이, 2 cm 이하로 떨어진 경우 최대 0.6 % 차이, PTV가 OAR을 포함하는 경우 최대 2.3 % 차이를 가졌다. 이 결과에 의하면 OAR과 PTV 간의 거리가 가까워짐에 따라 인접해있는 OAR 평균선량 및 최대선량에 있어 두 치료계획간 차가 커짐을 알 수 있다. 따라서 Jaw Tracking을 사용한 경우 일관성 있게 선량 감소가 있고 표면선량이 증가하지 않으므로 임상적인 유용성을 검증할 수 있었다. 향후 본 연구결과를 토대로 뇌, 두경부, 전립선과 같은 부위에 방사선 치료 시 선량감소 정도에 대한 추가 연구를 진행하여 각 부위에 따른 Jaw Tracking의 임상적 유용성 검증이 가능할 것으로 사료된다.

KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구 (A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards)

  • 이병설;최충석
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.63-72
    • /
    • 2017
  • 본 논문에서는 저압용 10회로 분전반을 전기공업협동조합(KEMC) 2102-610 규정에 근거하여 제작하였다. 또한, 개발된 10회로 분전반의 특성 평가를 실시하여 안전성을 확보하고자 한다. 개발된 10회로 분전반은 내식성, 절연 재료의 특성, 자외선 복사의 내성, 기계적 충격 등에 적합하도록 설계되었다. 개발된 분전반은 외함의 보호 등급, 감전방지와 보호회로, 개폐 장치와 구성품, 내부 전기 회로와 연결부, 외부 도체의 단자, 절연 특성, 온도 상승 시험, 열저항 등이 적합하도록 제작하였다. 개발된 10회로 분전반은 단상 회로와 3상 회로 등으로 구분되어 있다. 분기된 각각의 차단기 부하측에 센서 모듈을 설치하여 부하의 전선로에서 발생되는 누설전류의 크기를 실시간 측정할 수 있다. 그리고 부하의 용도 및 목적 등에 따라 회로를 증설할 수 있고, 각각의 부하 상태 역시 실시간 부하 관리 및 점검이 가능하다. 개발된 10회로 분전반의 온도 상승 시험을 실시한 곳은 인입 접속부, 주회로 및 분기회로 모선, 모선지지물 등 18 개소이다. 온도가 가장 높게 측정된 곳은 분기회로 모선용 MCCB 전원측 접속부의 R-phase으로 $65.3^{\circ}C$, 부하측은 T-phase으로 $61.6^{\circ}C$로 기록되었다. 그리고 내열 실험 장치를 이용하여 MCCB를 $180^{\circ}C$에서 6시간 동안 열적 스트레스를 인가하였을 때 작동 손잡이의 변형이 확인되었고, 트립 상태로 이동한 것이 확인되었다.

비디오 흉강경을 이용한 흉부수술에 대한 고찰 (Video-Assisted Thoracic Surgery (VATS))

  • 김진;김민호;구자홍;김공수
    • Journal of Chest Surgery
    • /
    • 제29권10호
    • /
    • pp.1143-1147
    • /
    • 1996
  • 최근들어 비디오 흉강경을 이용한 흉부수술은 다양한 흉부질환에 이용되고 있다. 전북대학교 의과대학 흉부외과학교실에서 1992년 8월부터 1995년 7훨까지 비디오 흉강경을 이용한 흉부수술을 46예 시행 하였다. 20명이 남자, 26명이 여자이었고 이들의 연령 분포는 14세에서 56세이었다. 대상질환은다한증 21예, 종격동 종양 12예, 기홍 10예, 식도의 평활근종 1예, 그리고 Raynaud's syndrome과 Burger's disease가 각각 1예씩이었다. 평균 수술시간은 89.7분이었고, 개흉술로 전환한 경우는 없었다. 사용한 트로카의 평균 숫자는 3개, 수술 후 흉관 거치 기간은 평균 1.8일, 그리고 수술 후 평균 입원 기간은 4.3일이 었다. 수술후 합병증은 5예(잔류기흉 1예, 횡격신경마비 1예, 지속적 공기 누출 2예, 대상성 과발한 1예)가 있었다. 지속적인 공기누출이 있었던 환자중 1예에서는 술후 3일째 개흉하여 폐부분절제술을 시행하였고 다른 1예에서는 술후 4일째 화학적 흉막유착술을 시행하여 공기 누출을 막을 수 있었다. 종격동 종양 절제술을 받은 환자중 1예에서는 조직검사상 흉선암으로 판명되어 6주간 5600cgy의 방사선 치료를 받 았다. 전체적으로 수술후 사망한 환자는 없었다. 흉강경을 이용한 흉부수술은 수술후 통증과 입원 기간을 감소시킬 수 있었고, 미용상의 이점이 있었다.

  • PDF

MOCVD로 성장한 β-Ga2O3 박막에 대한 Mg 불순물 주입 효과 (The effects of Mg impurities on β-Ga2O3 thin films grown by MOCVD)

  • 박상훈;이서영;안형수;유영문;양민
    • 한국결정성장학회지
    • /
    • 제28권2호
    • /
    • pp.57-62
    • /
    • 2018
  • 본 연구에서는 Mg acetate 수용액을 사용한 간편한 도핑방법으로 불순물을 주입하여 성장한 $Ga_2O_3$ 박막의 불순물 주입 효과에 대해 연구하였다. MOCVD 방법을 이용해 Si 기판 위에 undoped $Ga_2O_3$ 박막과 Mg-doped $Ga_2O_3$ 박막을 각각 $600^{\circ}C$$900^{\circ}C$의 성장온도에서 30분간 성장하였다. 표면 형상 분석 결과 Mg 불순물 주입에 따른 큰 차이는 확인되지 않았으며 $900^{\circ}C$에서 성장한 박막의 표면이 $600^{\circ}C$에서 성장한 박막의 표면보다 큰 거칠기를 가지고 다결정화 되는 것을 확인하였다. 광학적 특성 분석 결과, 도핑된 샘플의 경우 전체적인 발광 피크가 red shift 되었고 UV 방출 세기가 커지는 특성을 보였다. I-V 측정 결과로부터 Mg 불순물에 의해 $600^{\circ}C$ 성장 박막의 누설전류가 감소하고, $900^{\circ}C$ 성장 박막의 광전류는 증가하는 효과를 확인하였다.