• Title/Summary/Keyword: Radiation Leakage

Search Result 206, Processing Time 0.025 seconds

The Analysis of Electrical Conduction and Corrosion Phenomena in HVDC Cooling System and the Optimized Design of the Heat Sink of the Semiconductor Devices (HVDC 냉각시스템의 전기전도현상 및 부식현상 기술 분석과 스위칭 소자의 방열판 최적 설계 검토)

  • Kim, Chan-Ki;Park, Chang-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.484-495
    • /
    • 2017
  • In HVDC thyristor valves, more than 95% of heat loss occurs in snubber resistors and valve reactors. In order to dissipate the heat from the valves and to suppress the electrolytic current, water with a high heat capacity and a low conductivity of less than 0.2 uS/cm must be used as a refrigerant of the heat sink. The cooling parts must also be arranged to reduce the electrolytic current, whereas the pipe that supplies water to the thyristor heat sink must have the same electric potential as the valve. Corrosion is mainly caused by electrochemical reactions and the influence of water quality and leakage current. This paper identifies the refrigerants involved in the ionization, electrical conductivity, and corrosion in HVDC thyristor valves. A method for preventing corrosion is then introduced. The design of the heat sink with an excellent heat radiation is also analyzed in detail.

Comparison of theoretical and machine learning models to estimate gamma ray source positions using plastic scintillating optical fiber detector

  • Kim, Jinhong;Kim, Seunghyeon;Song, Siwon;Park, Jae Hyung;Kim, Jin Ho;Lim, Taeseob;Pyeon, Cheol Ho;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3431-3437
    • /
    • 2021
  • In this study, one-dimensional gamma ray source positions are estimated using a plastic scintillating optical fiber, two photon counters and via data processing with a machine learning algorithm. A nonlinear regression algorithm is used to construct a machine learning model for the position estimation of radioactive sources. The position estimation results of radioactive sources using machine learning are compared with the theoretical position estimation results based on the same measured data. Various tests at the source positions are conducted to determine the improvement in the accuracy of source position estimation. In addition, an evaluation is performed to compare the change in accuracy when varying the number of training datasets. The proposed one-dimensional gamma ray source position estimation system with plastic scintillating fiber using machine learning algorithm can be used as radioactive leakage scanners at disposal sites.

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

Nuclear power utilization as a future alternative energy on icebreakers

  • M. Bayraktar;M. Pamik
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.580-586
    • /
    • 2023
  • Diversified fuel types such as methanol, hydrogen, liquefied natural gas, ammonia, biofuels, have been come to fore in consideration of the limitations, regulations, environmental perception and efficient use of resources on maritime sector. NE is described as a substantial alternative energy source on the marine vessels in the sense of de-carbonization and fuel efficiency activities carried out by IMO. Although NPVs have been constructed for the merchant, navy and supply fields over the years, their numbers are few and working ranges are quite limited. NE generation techniques, reactor types, safety and security issues in case of any leakage or radiation pollution are analyzed and comparisons are performed between fossil-based fueled and NP based on icebreakers. The comparison are conducted on the basis of dimensions, resistances and operational competences by the VIKOR. NP icebreakers operated in recent years occupy a notable position in the ranking, although fossil fueled ones are most prevalent. Consequently, refueling period and emissions are the principal benefits of NPVs. Nevertheless, the use of such systems on marine vessels especially for merchant ships may come to the fore when all concerns in terms of safety, security and society are resolved since the slightest mistake can have irreversible consequences.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Postoperative Complications after Preoperative Chemoradiotherapy Combined with Hyperthermia in Locally Advanced Rectal Cancer (국소 진행성 직장암의 수술전 동시 화학방사선치료와 온열치료병합시 수술후 부작용)

  • Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • We investigated whether regional hyperthermia (HT) increased post-surgical complications in patients with locally advanced rectal cancer treated with preoperative concurrent chemoradiotherapy (CCRT). Between 1996 and 2007, 205 patients treated with preoperative CCRT and curative surgery were evaluable for the analysis of acute and late toxicities. A total dose of 39.6 Gy or 45 Gy was delivered concurrently with one or two cycles of chemotherapy (5-fluorouracil, leucovorin). Eighty-eight patients received regional HT twice a week using an 8-MHz radiofrequency capacitive heating device. Surgery was performed 4~6 weeks after the completion of preoperative CCRT. The median age was 59 years (range, 18~83) and the median follow-up period was 61months (range, 2~191). The 5-year overall survival and complication-free survival rate of all patients was 77.4% and 73.7%, respectively. Early leakage, delayed leakage, anastomotic stricture, fistula, and small bowel obstruction occurred in 1.0%, 2.9%, 1.5%, 5.9%, and 17.1%, respectively. HT did not increase all kinds of complications. The 5-year complication-free survival rate was 71.8% in the non-HT group and 76.3% in the HT group (p=0.293). Regional HT did not increase postoperative complications in patients with locally advanced rectal cancer treated with preoperative CCRT followed by curative surgery.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Results of Preoperative Concurrent Chemoradiotherapy for the Treatment of Rectal Cancer (직장암의 수술 전 동시적 항암화학방사선치료 결과)

  • Yoon, Mee-Sun;Nam, Taek-Keun;Kim, Hyeong-Rok;Nah, Byung-Sik;Chung, Woong-Ki;Kim, Young-Jin;Ahn, Sung-Ja;Song, Ju-Young;Jeong, Jae-Uk
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate anal sphincter preservation rates, survival rates, and prognostic factors in patients with rectal cancer treated with preoperative chemoradiotherapy. Materials and Methods: One hundred fifty patients with pathologic confirmed rectal cancer and treated by preoperative chemoradiotherapy between January 1999 and June 2007. Of the 150 patients, the 82 who completed the scheduled chemoradiotherapy, received definitive surgery at our hospital, and did not have distant metastasis upon initial diagnosis were enrolled in this study. The radiation dose delivered to the whole pelvis ranged from 41.4 to 46.0 Gy (median 44.0 Gy) using daily fractions of $1.8{\sim}2.0\;Gy$ at 5 days per week and a boost dose to the primary tumor and high risk area up to a total of $43.2{\sim}54\;Gy$ (median 50.4 Gy). Sixty patients (80.5%) received 5-fluorouracil, leucovorin, and cisplatin, while 16 patients (19.5%) were administered 5-fluorouracil and leucovorin every 4 weeks concurrently during radiotherapy. Surgery was performed for 3 to 45 weeks (median 7 weeks) after completion of chemoradiotherapy. Results: The sphincter preservation rates for all patients were 73.2% (60/82). Of the 48 patients whose tumor was located at less than 5 cm away from the anal verge, 31 (64.6%) underwent sphincter-saving surgery. Moreover, of the 34 patients whose tumor was located at greater than or equal to 5 cm away from the anal verge, 29 (85.3%) were able to preserve their anal sphincter. A pathologic complete response was achieved in 14.6% (12/82) of all patients. The downstaging rates were 42.7% (35/82) for the T stage, 75.5% (37/49) for the N stage, and 67.1% (55/82) for the overall stages. The median follow-up period was 38 months (range $11{\sim}107$ months). The overall 5-year survival, disease-free survival, and locoregional control rates were 67.4%, 58.9% and 84.4%, respectively. The 5-year overall survival rates based on the pathologic stage were 100% for stage 0 (n=12), 59.1% for stage I (n=16), 78.6% for stage II (n=30), 36.9% for stage III (n=23), and one patient with pathologic stage IV was alive for 43 months (p=0.02). The 5-year disease-free survival rates were 77.8% for stage 0, 63.6% for stage I, 58.9% for stage II, 51.1% for stage III, and 0% for stage IV (p<0.001). The 5-year locoregional control rates were 88.9% for stage 0, 93.8% for stage I, 91.1% for stage II, 68.2% for stage III, and one patient with pathologic stage IV was alive without local recurrence (p=0.01). The results of a multivariate analysis with age (${\leq}55$ vs. >55), clinical stage (I+II vs. III), radiotherapy to surgery interval (${\leq}6$ weeks vs. >6 weeks), operation type (sphincter preservation vs. no preservation), pathologic T stage, pathologic N stage, pathologic overall stage (0 vs. I+II vs. III+IV), and pathologic response (complete vs. non-CR), only age and pathologic N stage were significant predictors of overall survival, pathologic overall stage for disease-free survival, and pathologic N stage for locoregional control rates, respectively. Recurrence was observed in 25 patients (local recurrence in 10 patients, distant metastasis in 13 patients, and both in 2 patients). Acute hematologic toxicity ($\geq$grade 3) during chemoradiotherapy was observed in 2 patients, while skin toxicity was observed in 1 patient. Complications developing within 60 days after surgery and required admission or surgical intervention, were observed in 11 patients: anastomotic leakage in 5 patients, pelvic abscess in 2 patients, and others in 4 patients. Conclusion: Preoperative chemoradiotherapy was an effective modality to achieve downstaging and sphincter preservation in rectal cancer cases with a relatively low toxicity. Pathologic N stage was a statistically significant prognostic factor for survival and locoregional control and so, more intensified postoperative adjuvant chemotherapy should be considered in these patients.