• Title/Summary/Keyword: Radiation Effect

Search Result 3,580, Processing Time 0.034 seconds

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Future Development of Genetics and the Broiler (BROILER 육종기술의 전망)

  • 오봉국
    • Korean Journal of Poultry Science
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 1981
  • In trying to predict the effect of genetics on the broiler in the year 2000, this is a relatively short period of time as far as broiler genetics in concerned. Modern broiler genetics started around 1945 and tremendous gains when made in past 35 years. Futher improvements on broiler will depend on the evolution and revolution: 1. Evolution: (1) Growth rate has been made 4-5% per year. (2) Feed conversion has improved approximately 1% per year. (3) Abdominal fat is becoming a major complaint in broiler. (4) Because of the changing life-style, broiler meat sales in the future will be more and more in cut-up form. (5) Breeding for stress resistance and selection for docile temperament can be important in order to funker improve fled efficiency. (6) In female parent stock, reproduction characteristics are in many can negatively correlated with the desired broiler traits. (7) Egg production and hatchability in moot commercial parent nod m at a fairly high level. (8) In male parent stock, the heavier and mon super-meat-type male lines are desired to Product better broilers. 2. Revolution: Trying to forecast revolutionary change in broiler genetics is highly speculative, as sudden change are aften unpredictable. (1) Species hybridization, such as a turkey-chicken cross (2) Biochemical tools, such as blood typing. (3) Mutation breeding by radiation or chemical mutagentia. (4) Broiler breeding would be to change the phenotypic appearance by single gene, such as naked, wingless. (5) Changes in production techniques. such as growing in cage or growing in filtered air positive pressure houses.

  • PDF

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.

Correlation Coefficients between Pine Mushroom Emergence and Meteorological Elements in Yangyang County, Korea (양양지역 송이 발생과 기상요소의 상관관계)

  • Shim, Kyo-Moon;Ko, Cheol-Soon;Lee, Yang-Soo;Kim, Gun-Yeob;Lee, Jeong-Taek;Kim, Soon-Jung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.3
    • /
    • pp.188-194
    • /
    • 2007
  • The relationships between pine mushroom emergence and meteorological factors were analyzed with three years (from 2003 to 2005) of measurement data at Yangyang site, in order to evaluate the effect of micrometeorological environment on pine mushroom production. fine mushroom was daily monitored and collected in the survey area during the its producing period (approximately one month). Pine mushroom production was highest in 2005 with the meteorological conditions of high temperature and frequent rainfalls in October. The production was lowest in 2004 due to dry conditions from mid September to late October, The meterological factors related to humidity (i.e., relative humidity, soil water content, and precipitation) were better correlated than those related to temperature (i.e., air and soil temperature, soil heat flux and solar radiation) with pine mushroom production. However, all of the correlation coefficients were statistically insignificant with values ranging from 0.15 to 0.46. Such poor correlations may be attributed to various other environmental conditions (e.g., topography, soil, vegetation, other fungi, the relationship between pine mushroom and pine forest) affecting pine mushroom production. We found that a mycelium requires a stimulation of low temperature (of three-day moving average) below $19.5^{\circ}C$, in order to farm a mushroom primordium which grows to pine mushroom after 16 days from the stimulation. We also found that the pine mushroom production ended when the soil temperature (of three-day moving average) fell below $14.0^{\circ}C$.

Palliative Effect of Radiation Therapy in Management of Symptomatic Osseous Metastases (골 전이암에서 고식적 방사선치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.1
    • /
    • pp.102-109
    • /
    • 1992
  • Bone metastases represent an important and frequent clinical problem in patients with advanced cancers. Especially, painful bone metastases are common features in these patients. Radiotherapy is an effective tool for palliative aim of painful metastatic osseous lesions. Various treatment results have been previously reported. The present retrospective study was aimed to evaluate the efficacy of palliative irradiation on pain relief, with the goal of selecting appropriate irradiation dose schedule. Radiotherapy consisted of 5times a week with a various fractional dose between 180 and 400cGy. The response of pain relief and the survival time after completion of radiotherapy are related to total dose and most of the patients have shown a similar response by the end of radiotherapy. The higher dose and the more aggressive multimodality treatment, the better pain control and the longer survival time.

  • PDF

Radurization Effect of Korean Mackerel (한국산 고등어의 방사선 조사효과)

  • CHO S. J.;CHOE Y. K.;LEE S. Y.;BYUN S. M.;CHUNG J. R.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.219-226
    • /
    • 1985
  • To investigate potential application of radurization technique as an effective tool for controlling histamine accumulation, histamine contents were determined in fresh Korean mackerel meat samples irradiated at six dose levels of gamma radiation up to 1 Mrad during 35 day-storage at $0^{\circ},\;5^{\circ}\;and\;10^{\circ}C$. Total bacterial counts, total volatile bases and trimethylamine contents were also estimated. The minimum and maximum doses for Korean mackerel were determined to be 0.2 and 0.5 Mrad, respectively. Irradiation induced redening of fish muscle tissue and redening appeared to be dose dependent. At low doses, this redening contributed positively to the overall sensory qualities. At 0.5 and 1.0 Mrad, on the other hand, meat samples were excessively redened to the extent that red and white muscle layers were not readily distinguishable. No appreciable histamine accumulation occured during entire 35 day-storage in fresh mackerel meats, whether irradiated or not, when they were kept at ice temperature. At $5^{\circ}C$, histamine started to accumulate slightly during late storage in the samples irradiated at low doses. Even in the unirradiated samples, the histamine accumulation did not exceed the level of 10.0 mg per 100g meat until the 28th day at $5^{\circ}C$. At $10^{\circ}C$, however, histamine accumulation in the unirradiated was phenomenal from very early storage and the values reached 827.5 mg per 100g meat by the 35th day, while histamine accumulation in the irradiated was severely suppressed. Irradiation invariably brought about a significant reduction of initial microflora, disrupting normal spoilage pattern. This was reflected in the suppression of not only histamine but also total volatile bases and trimethylamine accumulation during post-irradiation storage at refrigerated temperatures.

  • PDF

Cell Protective Effects of Enzymatic Hydrolysates of Citrus Peel Pectin (귤피 펙틴 유래 효소적 가수분해물의 세포 보호 효과)

  • Kwon, Soon Woo;Ko, Hyun Ju;Bae, Jun Tae;Kim, Jin Hwa;Lee, Geun Soo;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.1
    • /
    • pp.75-85
    • /
    • 2016
  • Pectin, a naturally occurring polysaccharide, has in recent years attracted considerable attention. Its benefits are increasingly appreciated by scientists and consumers due to its safety and usefulness. The chemistry and gel-forming characteristics of pectin have enabled to be used in pharmaceutical industry, health promotion and treatment. Yet, it has been rarely used in cosmetics because of its incompatibility with many cosmetic ingredients, including alcohols, and unstable viscosity of pectin gels under various pH and salt conditions. However, low-molecular-weight pectin oligomers have excellent biological activities, and depolymerization of pectin to produce cosmetic ingredients would be very useful. In this study, we attempted the development of cosmetic ingredients using pectin with an excellent effect on human skin. We developed a bio-conversion process that uses enzymatic hydrolysis to produce pectin hydrolysates containing mainly low-molecular-weight pectin oligomers. Gel permeation chromatography was used to determined the ratio of hydrolysis. The molecular weight of the pectin hydrolysates obtained varied between 200 and 2,700 Da. The two newly developed low-molecular-weight pectin hydrolysates, LMPH A and B, had higher anti-oxidative activities than pectin or D-galacturonic. Exposure to UVB radiation induces apoptotic cell death in epidermal cells. Annexin V binding and propidium iodide uptake were measured by flow cytometry to evaluate UVB-induced cell death in HaCaT cells. Both LMPH A and B reduced UVB-induced cell death and increased cell proliferation by 22% and 30% at 0.5% concentration respectively, while pectin had no significant activity. In conclusion, this study suggests that the newly developed low-molecular-weight pectin hydrolysates can be used as safe and biologically active cosmetic ingredients.

Antioxidative Effects and Component Analysis of Extracts of the Rumex acetosa L. (수영 전초 추출물의 항산화 활성 평가 및 성분 분석)

  • Jeong, Yoo Min;Kim, Ho Jae;Lee, Su Hyun;Jang, Do Yun;Choi, Yae Chan;Min, Na Young;Gong, Bong Ju;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.4
    • /
    • pp.391-402
    • /
    • 2014
  • In this study, the antioxidative effects and component analysis for the extracts of Rumex acetosa L. were investigated. All experiments were performed with 50% ethanol extract, ethyl acetate fraction and aglycone fraction obtained from dried R. acetosa L.. Free radical scavenging activities (1,1-diphenyl-2- picrylhydrazyl) size of, in the order of aglycone fraction > ethyl acetate fraction > 50% ethanol extract, aglycone fraction ($45.10{\mu}g/mL$) showed the highest radical scavenging activity. Reactive oxygen species (ROS) scavenging activity (total antioxidant capacity, $OSC_{50}$) on ROS generated in $Fe^{3+}-EDTA/H_2O_2$ system was also, in the order of ethyl acetate fraction> aglycone fraction> 50% ethyl acetate fraction, ethyl acetate fraction ($2.68{\mu}g/mL$) was shown a great antioxidant capacity. The total antioxidant capacity of the ethyl acetate fraction was found to be greater than L-ascorbic acid, known as a typical hydrophilic antioxidant ($6.88 {\mu}g/mL$). The cellular protective effects of R. acetosa L. extracts on the $^1O_2$-induced cellular damage of human erythrocytes were exhibited at all concentration-dependent ($1{\sim}25{\mu}g/mL$). Especially, aglycone fraction (${\tau}_{50}$, 104.80 min) in $25{\mu}g/mL$ showed the most protective effect among extracts. Components of the ethyl acetate fraction obtained from R. acetosa L. extracts were analyzed by TLC, HPLC chromatogram, LC/ESI-MS/MS. As a result, the ethyl acetate fraction contained several flavonoids, such as orientin, isoorientin, vitexin, isovitexin. These results indicate that the R. acetosa L. extracts can be used as antioxidants in biological systems, particularly skins exposed to UV radiation by quenching and/or scavenging $^1O_2$ and other ROS. Thus, the extracts of R. acetosa L. could be applicable to new anti-aging cosmeceutical ingredients.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.