The Quotient of Absorbed Dose and the Collision Part of Kerma for Photon Beams

  • Jun, Jae-Shik;Loevinger, Robert
    • Journal of Radiation Protection and Research
    • /
    • 제5권1호
    • /
    • pp.7-10
    • /
    • 1980
  • With the conceptual definition of the quotient(${\beta}$) of absorbed dose and the collision part of kerma for photon beams, the procedure of computing ${\beta}$ is briefly described. A series of calculations of ${\beta}$ was carried out for photons of 0.4, 0.5, 1 and 2 MeV in polystyrene, carbon, air and aluminum. Resultant values are tabulated and evaluated.

  • PDF

kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰 (Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography)

  • 나종억;이도근;김진수;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.67-74
    • /
    • 2009
  • 목 적: 전립선암 환자를 대상으로 kV 콘빔CT를 이용한 영상유도방사선치료 시 촬영조건에 따른 인체의 각 장기들에 미치는 흡수선량(absorbed dose)과 유효선량(effective dose)을 비교 평가해 보고자 한다. 대상 및 방법: 환자를 대상으로 직접 실험할 수 없으므로 인체의 구성과 조직이 흡사한 인체 모형 팬텀(Anderson rando Phantom, Alderson Research Laboratories Inc., USA)과 전산화 단층 모의치료기(Lightspeed RT CT, GE, USA)를 이용하여 국제 방사선 방호 위원회(International Commission on Radiological Protection, ICRP)에서 권고된 신체 내 중요 장기들을 묘사하였다. 팬텀 내부의 묘사된 주요 장기에 선량 측정을 위하여 열형광선량계(TLD 100 Lif rods, Harshaw Chemical Co., USA)를 1~8개 삽입한 후 팬텀의 중심을 전립선에 위치시키고, On board imager (OBI) System이 부착된 의료용 선형 가속기(Clinac iX, Varian, USA)를 이용하여 두 가지 촬영모드인 표준모드(Standard-mode, A-mode)와 저선량모드(Low-dose mode, B-mode)에서 kV 콘빔 CT 촬영을 각 3회씩 반복해서 측정하였다. 결 과: 인체 모형 팬텀을 이용하여 전립선암 환자를 대상으로 한 kV 콘빔 CT 촬영을 시행한 결과 전립선, 방광, 직장에 대한 흡수선량은 A-mode인 경우 각각 5.5 cGy/1회, 6.5 cGy/1회, 5.7 cGy/1회, B-mode인 경우 1.1 cGy/1회, 1.3 cGy/1회, 1.2 cGy/1회 결과를 보였다. 각 장기에 대한 조직가중치를 고려한 유효선량은 A-mode와 B-mode에서 19.1 mSv, 4.4 mSv의 결과로 나타났다. kV 콘빔CT 촬영 시 인체에 미치는 유효선량을 측정한 결과, 전립선암 영상유도방사선치료 시 A-mode 콘빔CT는 B-mode 콘빔CT보다 환자가 받는 선량이 약 4배 이상 증가하는 것을 알 수 있었다. 결 론: 그러므로 전립선암 영상유도방사선치료 시 환자가 받는 치료 이외의 선량을 고려했을 때 가능한 B-mode 또는 낮은 촬영 조건을 설정하여 환자가 받는 치료이외선량을 가능한 한 줄일 필요가 있다고 사료된다.

  • PDF

Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가 (Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor)

  • 천금성;김창욱;김회남;허경훈;송진호;홍주영;정재용
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.97-103
    • /
    • 2010
  • 목 적: 상이한 치료장비를 이용하여 동일 부위에 중복하여 방사선치료 시 전산화치료계획장치간에 호환이 되지 않아 정상조직(Normal Tissue)의 총 흡수선량에 대한 평가의 한계점이 있다. 본 연구에서는 토모테라피(Tomotherapy)와 선형가속기(Linear accelerator)를 이용하여 동일 부위를 중복 치료할 때 환자가 받는 선량을 평가하고자 한다. 대상 및 방법: 인체모형팬텀(Anthropomorphic Phantom)을 대상으로 종양 및 정상조직을 묘사하여 선형가속기 치료계획장치 (Pinnacle 8.0: RTP)로 종양에 45 Gy 선량을 처방하고, 토모테라피 치료계획장치에서 종양에 15 Gy 선량을 처방하여 치료계획을 수립하였다. 토모테라피에서 수립된 치료계획을 통합가능 치료계획장치(Oncentra: RTP)에 전송한 후 동일한 조건으로 토모테라피 치료계획을 재현한 후 선형가속기에서 치료한 45 Gy를 합하여 총 선량 60 Gy의 치료계획을 구현하였다. 흡수선량 평가를 위해 두 개의 방사선 치료계획장치에서 얻어진 흡수선량(최소, 최대, 평균 선량) 및 관심 선량체적에 대해 서로 합(Total)한 값과 하나로 통합(Integration)하여 얻어진 값을 비교 분석하였다. 이를 바탕으로 본원에서 치료받은 환자 중 선형가속기와 토모테라피로 동일 부위에 치료 받은 5명(두경부 2명, 복부 1명, 골반부 2명)에 대하여 동일한 방법으로 종양 및 정상 조직의 흡수선량을 비교 분석하였다. 결 과: 인체모형팬텀에서 하나로 통합하여 얻어진 값과 서로 합한 값의 비교에서 최소선량은 비장(Spleen, 12.4%), 최대선량은 소장(Small bowl, 10.2%)과 척수(Spinal cord, 5.8%)에서 큰 차이를 나타냈다. 두경부 환자의 경우 최소선량은 구강(Oral cavity, 20.3%), 오른쪽 수정체(Rt lens, 7.7%)에서 큰 차이를 나타냈으며, 최대선량은 척수(22.5%), 뇌간(Brain stem; 12.0%), 시 신경교차(Optic chiasm; 8.9%), 오른쪽 수정체(11.5%), 하악골(Mandible bone, 8.1%), 뇌하수체(Pituitary gland, 6.2%)에서 뚜렷한 차이가 나타났다. 복부 환자의 경우 최대선량은 왼쪽 신장(Lt kidney, 20.3%), 위(Stomach, 8.1%)에서 큰 차이가 나타났고, 골반 부위 환자의 경우 최소 선량은 방광(Bladder, 15.2%), 최대선량은 소장(5.6%), 방광(5.5%)에서 큰 차이를 나타냈다. 또한 동일 부위 방사선치료계획 시 정량화되지 못했던 신장의 20 Gy를 받은 체적($V_{20}$)에서 37%, 간(Liver)의 25 Gy를 받은 체적($V_{25}$)에서 23%가 선량체적히스토그램(DVH)에서 나타났다. 결 론: 하나로 통합하여 얻어진 값과 서로 합한 값의 비교에서 최소선량은 높게, 최대선량은 낮게, 평균선량은 동일한 값으로 나타났다. 또한 관심장기의 선량 체적($V_{20}$)보다 낮은 선량을 처방했을 때 구현하지 못했던 종양 및 정상조직의 흡수선량에 대하여 평가를 할 수 있었다. 향후 상이한 치료 장치들을 이용한 동일 부위 치료 시 흡수선량의 통합 평가뿐만 아닌 정확한 선량분포를 구현할 수 있는 치료계획장치의 개발이 요구되어지며, 이에 관련된 연구가 진행되어져야 한다.

  • PDF

Evaluation of the Lens-absorbed Dose of the Scattered Radiation Generated During Tomotherapy IMRT to the H&N Cancer Patient

  • Choi, Jae-Won;Lee, Hae-Kag;Cho, Jae-Hwan;Choi, Cheon Woong;Ju, Myung Sik;Chang, Bok Soon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.141-145
    • /
    • 2017
  • This paper uses a glass dosimeter to evaluate the lens-absorbed dose of scattered radiation generated in tomotherapy intensity modulated radiation therapy (IMRT). The head and neck portion of the rando phantom was subjected to a CT scan. The tomotherapy plan was designed to ensure delivery of the prescribed total 70 Gy day 2.2 Gy. With the lens portion of the glass dosimeter, a 5mm bolus was subjected to the scattered radiation treatment, and the dose was measured in each of the three megavoltage CT (MVCT) modes. The result is multiplied by 30 times and was determined once as the mean value. The measurement at the MVCT Coarse mode is RT mode 10.797 mGy, that for the Normal mode is 13.360 mGy, for the Fine mode is a maximum of 22.872 mGy, and for the treatment mode is 895.830 mGy. A small amount of scattered radiation in the MVCT is measured in the lens scattered radiation, but scattered radiation during treatment was measured to be near 1 Gy on the lens. Compared to a one-time radiation treatment of 2.2 Gy, the survey showed something unexpected in that it was half the value of that research to the patient. Therefore, will be aware of how much of an influence there will be on sensitive organs, such as the lens by scattered radiation generated during intensity modulated radiation therapy.

TLD를 이용한 X-선 수중 흡수선량 측정 및 해석 (Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD)

  • 오장진;전재식;하석호;김원식;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.21-28
    • /
    • 1988
  • LiF : PTEE를 사용하여 중경 X-선(HVL : 0,29, 0.84, 1.60, 2.62mmCu) 영역에 대한 수중 흡수선량을 측정 해석하였다. 이때 선량계 (0.4mm ${\times}\;{\phi}$12.5mm, hot-pressed LiF TLD-700)는 루사이트로 둘러 싸여 있고 물의 흡수선량은 각각의 TL출력 값에 Burlin의 공동이론을 적용하여 해석하였다. 그 결과 물 팬텀 속 깊이 5cm에서 흡수선량률의 측정 오차는 최대 ${\pm}5%$로 나타났다. 이 측정값을 측정 오차가 ${\pm}2%$의 간접절대측정방법인 이온화법에 의한 측정값과 비교한 결과 두 값의 차이는 LiF : PTFE의 측정오차 범위 내에서 일치하였다. 이와같은 결과로 LiF : PTFE를 이용한 수중 흡수선량 측정의 신뢰성을 확인할 수 있게 되었으며 이는 중경 X-선 영역에 대한 선량당량 평가의 근거로 활용 될 수 있을 것이다.

  • PDF

형광유리선량계의 계측 직선성 연구 (A Study on the Measurement Linearity of Photoluminescent Dosimeter)

  • 정경환;정동경;서정민
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.841-847
    • /
    • 2021
  • 방사선을 이용하는 관련 기관은 국내에 연구, 의료, 교육 등 다양하다. 최근에는 검진 및 의료기관의 방문 횟수가 증가하고 있다. 이로 인해 의료기관에서 방사선학적 검사 횟수가 증가하고 있다. 방사선작업종사자의 피폭뿐만 아니라 방사선 안전관리가 필요하다. 안전관리를 위해서 우선적으로 개인피폭선량계의 올바른 착용 및 착용 후 정확한 측정이 필요하다. 본 연구는 진단용 방사선발생장치의 방사선에 의한 PLD 소자의 계측 직선성을 평가하고 검증하려고 한다. 방사선 분할 조사 시간간격은 10, 30, 60 sec로 10회 조사와 거리에 따라 흡수선량 변화를 측정하기 위해서 조사거리를 30 ~ 100 cm까지 10 cm 간격으로 조사 후 측정하였다. 그 결과 시간 간격에 의한 흡수선량은 차이가 없었다. 이는 고흡수선량 연구에 진단용발생장치를 이용하여 다양한 연구에 도움이 될 것으로 여겨진다.

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가 (Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation)

  • 이준성;김양수;김민걸;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

Novel reforming of pyrolized fuel oil by electron beam radiation for pitch production

  • Jung, Jin-Young;Park, Mi-Seon;Kim, Min Il;Lee, Young-Seak
    • Carbon letters
    • /
    • 제15권4호
    • /
    • pp.262-267
    • /
    • 2014
  • Pyrolized fuel oil (PFO) was reformed by novel electron beam (E-beam) radiation, and the elemental composition, chemical bonds, average molecular weight, solubility, softening point, yields, and density of the modified patches were characterized. These properties of modified pitch were dependent on the reforming method (heat or E-beam radiation treatment) and absorbed dose. Aromaticity ($F_a$), average molecular weight, solubility, softening point, and density increased in proportion to the absorbed dose of E-beam radiation, with the exception of the highest absorbed dose, due to modification by free radical polymerization and the powerful energy intensity of E-beam treatment. The H/C ratio and yield exhibited the opposite trend for the same reason. These results indicate that novel E-beam radiation reforming is suitable for the preparation of aromatic pitch with a high ${\beta}$-resin content.

전악치근단방사선사진촬영, 파노라마방사선사진촬영 및 협각단층촬영시의 흡수선량 (Absorbed Dose in the Full-mouth Periapical Radiography, Panoramic Radiography, and Zonography)

  • 최순철;최항문
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.255-260
    • /
    • 1999
  • Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  • PDF