• Title/Summary/Keyword: Radiating

Search Result 601, Processing Time 0.028 seconds

The effect of Radiating Qui Therapy on human skin temperature (외기요법이 체표온도 변화에 미치는 영향)

  • Ro, Il-Ho;Kim, Byung-Wan;Jung, Kwang-Jo;Jo, Jung-Hyo;Hwang, Sang-Jun;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.12 no.1
    • /
    • pp.147-168
    • /
    • 2003
  • This study is about the relationship between the effect of Radiating Qui Therapy on human body and the resulting subjective qui sensation. Patients were between 30 and 50 years of age. n=21 persons received DITI (n=14 patients were provided, n=9 control group) twice examination with Radiating Qui Therapy. First all patients were examined by DITI. After treatment with Radiating Qui Therapy (n=14) both the treated and the control groups were eaxmined again. Radiating Qui Therapy is provided upright position. After Radiating Qui Therapy 92% of the treated group felt a significant qui sensation and 43.5 % felt a warmth at the abdomen and over the whole body. A data of this study show Radiating Qui Therapy has s stimulating effect on human skin temperature. As disease region and Qui sensation are very closely related to each other results strongly suggest that Radiating Qui Therapy could be used as a treatment for a several disease.

  • PDF

Change in Radiating Leg Pain After Traffic Accidents in Patients With and Without Herniated Intervertebral Disc

  • Youn, Deok-Won;Jeong, Hui-Gyeong;Kwon, Oh-Hoon;Choi, Ji-Hoon
    • Journal of Acupuncture Research
    • /
    • v.34 no.4
    • /
    • pp.185-189
    • /
    • 2017
  • Background: The aim of this study was to assess the change in radiating leg pain after traffic accidents in patients with and without herniated intervertebral disc (HIVD) and improvement of radiating leg pain after traffic accidents. Methods: This was an retrospective study of 188 patients. Patients who had been admitted to the Hospital of Korean Medicine with the complaint of radiating leg pain after traffic accidents, and who had undergone lumbar spine magnetic resonance imaging to determine the presence or absence of HIVD were observed from April to June 2016. We analyzed sex, age, length of admission, direction (to a single leg or to both legs) and locations, (medial, anterior, lateral or posterior side of the lower limb) of radiating leg pain, presence or absence of HIVD, and number, grade and position of HIVD. The Numeric Rating Scale (NRS) and Oswestry Disability Index (ODI) were used to evaluate the impact of radiating leg pain on patients. Results: Radiating leg pain NRS score decreased significantly in both the HIVD group (from $6.12{\pm}2.39$ to $4.31{\pm}1.87$, p < 0.001) and the no HIVD group (from $5.76{\pm}1.64$ to $3.85{\pm}1.41$, p < 0.001). ODI score also decreased significantly in both groups (HIVD, from $44.67{\pm}17.38$ to $26.83{\pm}13.18$; no HIVD, from $39.24{\pm}15.58$ to $19.69{\pm}12$.; both p < 0.001). Conclusion: There was no significant change in radiating leg pain after traffic accidents in patients with and without HIVD and improvement of radiating leg pain after traffic accidents.

The Effect of Cervical Traction on Pain & Symptom for Patients with Cervical Pain (경추부 견인이 경추부 통증 환자의 증세 및 통증에 미치는 영향)

  • Kim, Sung-Ho;Kim, Myung-Joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.67-75
    • /
    • 2001
  • The purpose of this study was to investigate the influence of cervical pain and radiating pain after cervical traction for patients with cervical pain. This evaluation was made 81 persons who cervical pain or radiating pain. The result of this study were as following ; 1. There were statistically significant decrease in cervical pain and radiating pain after cervical traction. 2. A type group(only neck pain ; n=5) and B type group(neck to elbow radiating pain ; n=11), there were pain decreased but there were not significant difference (p>0.05), C type group(neck to shoulder radiating pain group ; n = 14) and D type group(neck to hand radiating pain group ; n = 50), there were pain decreased before test then after test by VAS and significant difference(p<0.05).

  • PDF

Effect of far-infrared radiating products on cold hypersensitivity of lower limbs using Cold Stress Test (CST) : A pilot study (냉부하검사(CST)로 살펴 본 원적외선 기능성 제품이 족부냉증에 미치는 영향 : A pilot study)

  • Lee, Yoon-Jae;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.69-75
    • /
    • 2008
  • Purpose: We investigated the effect of far-infrared radiating products on cold hypersensitivity of lower limbs using CST. Methods: 7 patients with cold hypersensitivity of lower limbs were investigated in this study. Exclusive criteria was skin diseases, spinal nervous disease and external wounds. They were asked to answer the VAS of cold hypersensitivity at baseline and after 3 weeks. We measured temperature of lower limbs with Spectrum 9000 MB (Dorex Inc, USA). We performed cold stress test (CST) by 3 thermographic observation using DITI : 1st was taken after 15 minutes resting at $25^{\circ}C$, the 2nd was immediately taken after 1 minute soak in $20^{\circ}C$ water, the 3rd was taken at 15 minutes after soak. We performed 3 times of CST : 1st CST was perfomed at baseline, 2nd CST was perfomred after 1 week and just observation, 3rd CST was performed after 1 week using far-infrared radiating products (lasner, UMT, Korea). Results: After using products, temperature of foot incresed more than thigh area, but there was no significance. There was no statistical difference of VAS, change of temperature and CST between before and after using far-infrared radiating products. Conclusion: There was no statistical effect of far-infrared radiating products on change of temperature of lower limbs.

  • PDF

A Study on Smart Heat Radiating Sheet for Protecting Electronic Equipments on the Ship

  • Choi, Dong-Soo;Kim, Dong-Il;Kim, Doh-Yeol;Choi, Dong-Han;Kil, Gyung-Suk;Kim, Jae-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.35 no.7
    • /
    • pp.569-573
    • /
    • 2011
  • In this paper, we developed a Smart Heat Radiating Sheet(SHRS) having the absorption ability of more than 15 dB, and thermal conduction rate more than 20 W/mk for port logistics RFID(Radio Frequency IDentification) system by using AMP(Amorphous Metal Powder) and shielding sheet. Firstly, the EM(Electro_Magnetic) wave absorber samples were fabricated by using AMP and CPE (Chlorinated Polyethylene) with different composition ratios of 80 : 20 wt.% and 85 : 15 wt.%, respectively. Secondly, we fabricated the Smart Heat Radiating Sheet using the shielding sheet to attach EM Wave Absorber. As a result, the Smart Heat Radiating Sheet with absorption ability of 16 dB at 433 MHz and thermal conduction rate is 24 W/mk has been developed with the composition ratio of Amorphous Metal Powder : CPE = 85 : 15 wt.% and thickness of 5.5 mm.

New Radiating Edges-Coupling (REC) Model for the Gap Between Two Rectangular Microstrip Patch Antennas (구형 마이크로스트립 안테나의 간격에 대한 새로운 Radiating Edges-Coupling(REC) 모델)

  • Hong, Jae-Pyo;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.56-65
    • /
    • 1989
  • In this paper, a new model is presented which characterizs the coupling of the radiating edges between two rectangular microstrip patch antennas. This model, namely Radiating Edges-Coupling (REC) model, is derived from the equivalent circuit of the slitted parallel-plate waveguide filled with homogeneous dielectric. Applying the REC model to two coupled rectangular microstrip patch antennas, we obtain numerical S-parameter values of |$S_{11}$| and |$S_{12}$|for the various coupling separations, $S_e$=0.5, 1.0, 1.5, and 2.0mm. Theoretical results are in fairly good agreement with experimental results.

  • PDF

A Study on Fault Diagnosis for Planar Active Phased Array Antenna (평면 능동위상배열안테나 결함소자 진단방법에 관한 연구)

  • Jin-Woo Jung;Seung-Ho Kang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.11-22
    • /
    • 2023
  • A radiating elements fault diagnosis method with simplified radiation pattern measurement procedure was presented for planar active phased array antenna system. For presenting the mentioned method, the technique for linear approximation based on the radiation characteristics of a planar array configuration and a technique for solving a unique solution problem that occur in process of diagnosing a fault in a radiating elements were presented. Based on the presented method and a genetic algorithm, experimental simulations were performed for radiating element defect diagnosis according to various planar active phased array antenna configurations. As a result, it was confirmed that the presented radiating element fault diagnosis method can be smoothly applied to planar active phased antennas having various configurations.

Investigation on Numerical Integration for Radiation Heat Transfer in Radiating Fluid (복사유체의 복사열전달 수치 적분에 관한 연구)

  • Han Cho Young
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.43-51
    • /
    • 2004
  • Interaction between fluid flow and thermal radiation has received considerable attention due to its numerous applications in engineering field. In this case the thermofluid properties of radiating fluid vary with the variation of temperature field caused by absorption and emission of radiant heat. To analyze the radiation heat transfer in radiating fluid, the simultaneous solution of the radiative transfer equation (RTE) and the fluid dynamics equations is required. This means that the numerical procedure used for the RTE must be computationally efficient to permit its inclusion in the other submodels, and must be compatible with the other transport equations. The finite volume method (FVM) and the discrete ordinates method (DOM) are usually employed to simulate radiation problems in generalized coordinates. These two representative methods are examined and compared, especially in view of the numerical integration of the radiation intensity over solid angle. The FVM shows better accuracy than the DOM owing to less constraints of the selection of control angle.

Investigation on Numerical Integration for Radiation Heat Transfer in Radiating Fluid (복사유체의 복사열전달 수치 적분에 관한 연구)

  • Han Cho Young
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.62-70
    • /
    • 2004
  • Interaction between fluid flow and thermal radiation has received considerable attention due to its numerous applications in engineering field. In this case the thermofluid properties of radiating fluid vary with the variation of temperature field caused by absorption and emission of radiant heat. To analyze the radiation heat transfer in radiating fluid, the simultaneous solution of the radiative transfer equation (RTE) and the fluid dynamics equations is required. This means that the numerical procedure used for the RTE must be computationally efficient to permit its inclusion in the other submodels, and must be compatible with the other transport equations. The finite volume method (FVM) and the discrete ordinates method (DOM) are usually employed to simulate radiation problems in generalized coordinates. These two representative methods are examined and compared, especially in view of the numerical integration of the radiation intensity over solid angle. The FVM shows better accuracy than the DOM owing to less constraints of the selection of control angle.

  • PDF

Null Steering of Circular Array Using Array Factor for GPS Anti-Jam

  • Kwon, Taek-Sun;Lee, Jae-Gon;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.4
    • /
    • pp.267-269
    • /
    • 2018
  • In this letter, the null steering of a circular array is presented using a modified array factor (AF) for a global positioning system (GPS) anti-jam. The seven radiating elements were designed using a mu-zero resonance (MZR) circularly polarized (CP) antenna arranged toward the center. Since the radiating elements, which are arranged toward the center, have a CP characteristic, the AF of the seven radiating elements has to be modified considering the rotation angle of the nth radiating element. The phases of input ports can be calculated to implement a nulling of radiation patterns where the modified AF is zero. To verify the modified AF for null steering in the desired direction, two cases of power dividers operating in $L_2$ band (1.2276 GHz) were fabricated to achieve pattern nulling at a certain angle. The modified AF can be confirmed by a comparing the simulated and measured radiation patterns.