• Title/Summary/Keyword: Radiant Temperature

Search Result 307, Processing Time 0.031 seconds

Application Study of the Predictive Pulse Control for Floor Heating System (바닥난방을 위한 부하 예측식 펄스제어 방식의 적용성 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Yong-Bong;Na, Hee-Hyeong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.167-175
    • /
    • 2007
  • A predictive pulse control strategy as a means of improving the energy efficiency of radiant floor heating systems is explored. Experiments at the apartment with floor heating system are conducted to assess and compare the energy performance of the predictive pulse control strategy with an existing conventional control strategy. The Results showed that new suggested PPCM( Predictive Pulse Control Method) was available to decrease the gap of $1{\sim}1.5^{\circ}C$ between maximum and minimum indoor temperature of each rooms. Therefore PPCM method was favor to radiant floor heating system which have a delay time of 10-20 minutes for heat transfer by floor layers.

  • PDF

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.

Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies (바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석)

  • Lee, Joon-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

A Case Study on Thermal Performance for Transparent Glazing Space Considering Solar Radiation in Summer (여름철 일사를 고려한 투명 투과체 공간의 열환경 특성에 관한 사례연구)

  • Ryu, Young-Hee;Seo, Hye-Soo;Lee, Min-Jung;Nam, Ji-yeon;Song, Mi-Na;Chun, Chung-Yoon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, buildings with transparent glazing on exterior walls have increased. The transparent glazing on exterior walls gives an impression of opening through introducing external environment's elements to inside of the building, and has various merits and so on, but has defects in controling indoor environments. Especially, the excess of solar radiation in summer increases cooling load causing discomforts to occupants providing radiant environment with high temperature. Cooling load mainly depends on electricity comparing to heating load and intents to centralize specific time. So it is necessary to work out a countermeasure. In this study, showed P building with transparent glazing on exterior walls as a case, investigated indoor thermal performance, numerical analysis of P building in summer through comparing dry-sauna which is represented as radiant environment with high temperature. In the results of this study, transparent glazing space has radiant environment with high temperature such as dry-sauna because of the excess of solar radiation. Accordingly countermeasures are considered in building planning. As concrete methods, there are adiabatic effects using double glazing, use of sunscreen, blind, ventilation facilitation using natural draft, decrease of surface temperature through evaporation cooling and cooling coils.

A Study on the Combustion Characteristics and Radiation Efficiency of Metal Fiber Burners (메탈 화이버 버너에서의 연소 특성 및 복사 효율에 관한 실험적 연구)

  • Park, Ju-Won;Chung, Tae-Yong;Shin, Dong-Hoon
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.13-18
    • /
    • 2006
  • Radiant burners are applicable to drying, preheating and curing in materials manufacturing processes. High radiation efficiency is one of the most important performance criteria for these burners. The wide variation in reported radiation efficiencies are partly due to the differences in the measurement techniques. In the present work, water cooled radiant heat flux meter was used to measure radiant heat flux from a metal fiber mat burner. Non-contact type thermometer was also utilized to measure the surface temperature of the burner. Combustion gas was measured by gas analyzers. According to the thermal loads and stoichiometric ratios, radiant heat transfer ratio and combustion performance were discussed here in.

  • PDF

A Study on the Combustion Characteristics and Radiation Efficiency of Metal Fiber Burners (메탈 화이버 버너에서의 연소 특성 및 복사 효율에 관한 실험적 연구)

  • Park, Ju-Won;Chung, Tae-Yong;Shin, Dong-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2006
  • Radiant burners are applicable to drying, preheating and curing in materials manufacturing processes. Radiation efficiency is one of the important performance criteria for these burners. The wide variation in reported radiation efficiencies are partly due to the differences in the measurement techniques. In the present work, water cooled radiant heat flux meter was used to measure radiant heat flux from a metal fiber mat burner. Non-contact type thermometer was also utilized to measure the surface temperature of the burner. Combustion gas was measured by gas analyzers. According to the thermal loads and stoichiometric ratios, radiant heat transfer ratio and combustion performance were discussed here in.

  • PDF

A study on the applicability of radiant cooling using Ondol (온돌을 이용한 복사냉방의 가능성에 관한 연구)

  • 구소영;김용이;석호태;이현우;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.200-208
    • /
    • 2000
  • The use of air-conditioning systems for cooling in residential buildings has negative effects on the environment and causes the problem in peak electric power demand in summer. The objective of this study is to demonstrate the potential of radiant cooling systems using ondol as an alternative cooling system in our residential buildings. Computer simulation has been performed for the floor radiant cooling system performance. The results of this study show that. 1) This system can control the temperature of Ondol room within comfort limits. 2) This system can be operated with a little risk of condensation but the control of latent heat will make this system more potential.

  • PDF

A Study on the Suggestion of Thermal Comfort Range in Radiant Floor Ondol Heating System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.108-112
    • /
    • 2004
  • The purpose of this study is to investigate the characteristics of thermal comfort index and to present the thermal comfort range through regression analyses and experiment in a radiant floor heating system laboratory. The results were compared to the comfort zone of ISO-7730, and the applicability of the thermal comfort index to a radiant floor heating system was studied. On comparing the sedentary posture on the floor to sitting on the chair, the comfort zone and the neutral point of comfort index showed different values. It is considered that the influence of conduction from floor to the human is sufficient. Moreover, we could find a correlation between the thermal sensation votes of subjects, and the comfort indexes were lower than those by calculation.

A Study on GRNN Control Strategies for Floor Radiant Heating System in Residential Apartments (공동주택 바닥복사 난방시스템의 GRNN 제어 적용에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.830-836
    • /
    • 2012
  • In this study, the effects of heating control methods on heating control performance and energy consumption in the floor radiant heating control system of residential apartments were research by computer simulation. A general regression neural network(GRNN) control method for reducing indoor temperature overshoot and saving energy in floor radiant heating system is suggested. The GRNN control method shows good responses in comparison with the conventional and outdoor reset control methods for improving indoor thermal environment and reducing energy consumption.

A study on Fire Hazard of Electric Radiant Heating Systems with Thermal Storage Using Off-peak Electricity (심야용 축열식 전기온풍기의 화재 위험성에 관한 연구)

  • Park, Min-Yeong;Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • The purpose of this study is to identify the fire danger of the electric radiant heating system and check the way how to use it and the problems that could be possible through a actual case. We carry out an experiment to identify the possibility of the fire in the similar condition of the actual fire case. The results of this study are as follows. It is a possible condition to fire if the air blast of the electric radiant heating system is blocked by some combustible materials such as plastic bags continuously. A temperature sensor and a residual current device are necessary to disconnect the power source. It is also necessary to attach a notice in front of the electric radiant hearing system that shows users the fire danger to forbid the possible fire. Fires could be happened by internal defects of the electronic products. However, we can also find many external reasons to happen fires. Therefore, we need to check all reasons to make fires in the scene of a fire.

  • PDF