• Title/Summary/Keyword: Radial pulse

Search Result 193, Processing Time 0.03 seconds

A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer (3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구)

  • Kang, Hee-Jung;Kwon, Young-Sang;Kim, Dal-Lae;Kim, Kyung-Cheol;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

A Study on the Radial Pulse Detection System for the Total Macjin( I ) (총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ))

  • Kim, K.S.;Yang, S.Y.;Han, S.C.;Park, Y.B.;Kim, J.K.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave (3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법)

  • Yu, Seung-Yeon;Park, Eun-Sung;Choi, Ye-Bin;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

Observational Clinical Study on Mibyeong Based on Korean Medicine Diagnosis, Questionnaire, and Radial Artery Tonometry (한의사의 진단, 설문지, 맥진을 이용한 미병 관리에 관한 관찰적 임상연구)

  • Heeyoung Moon;Minsoo Kim;Su Hyun Lim;Younbyoung Chae;In-Seon Lee
    • Korean Journal of Acupuncture
    • /
    • v.40 no.2
    • /
    • pp.44-53
    • /
    • 2023
  • Objectives : This study was conducted to reveal the relationship between multiple factors of traditional Korean Medicine diagnosis and consider the further probabilities of treating people with physical and mental problems not defined as diseases, which is called 'Mibyeong' in traditional Korean Medicine. Methods : 40 healthy participants were included in the observational clinical trial. The participants were asked to complete health questionnaires (e.g. State-Trait Anxiety Inventory, Pittsburgh Sleep Quality Index, Stress Response Inventory) and they went through a traditional diagnosis process, including four stages of diagnosis (looking, listening/smelling, inquiring, and pulse taking), by a Korean Medicine doctor. Both the Korean Medicine doctor and an artery tonometry device performed the pulse diagnosis. Results : Although all participants were healthy people with no history of disease, more than half of participants had a problem related with severe level of fatigue (n=19), sleep disturbance (n=26) and stress (n=27) status according to the related questionnaires. Participants diagnosed with phlegm syndrome by the Korean Medicine doctor showed significantly greater score in phlegm pattern questionnaires than participants who were not. However, there was little agreement between the doctor's pulse diagnosis and radial artery tonometry results. Conclusions : We conducted a pulse diagnosis and measured health-related information along with the traditional Korean Medicine diagnose procedure, including four stages of diagnosis, and we found a linkage between diagnosis of phlegm and the phlegm pattern questionnaire score. The results suggest that a number of healthy participants, with no disease diagnosed, have Mibyoung symptoms which need further clinical management. Thus, we suggest that Mibyoung management programs based on qualified diagnosis tools and traditional Korean medicine diagnosis procedures be developed, and that future research using various diagnostic tools be carried out on a large population.

Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field (자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발)

  • Lee, Nam-Kyu;Kim, Keun-Ho;Lee, Sang-Suk;Yu, Ji-Hye;Yu, Jun-Sang;Sun, Seung-Ho;Chang, Sei Jin;Hong, Yu-Sik
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.104-109
    • /
    • 2013
  • Clip-type pulsimeter equipped with Hall device and a minute permanent magnet as sensing the minute movement of a radial artery was developed. The clinical data of the 120 number of subject acquisited through the clip-type pulsimeter did treated with a typical statistical logistic regression analysis. The prediction algorithm for the replete pulse and vacuous pulse was studied. The reflective peak time and the notch peak time were major parameters to discern the replete pulse and vacuous pulse. The discrimination rate was 65%. It suggests that the logistic regression equations are possible to use the diagnosis index to predict and discern the oriental pulse wave.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

A New TE/TR Reduction Technique in MR Pulse Sequences and Its Application to Radial Imaging

  • 김용권;류연철;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.18-18
    • /
    • 2003
  • 목적: MRI 시스템에서 얻어지는 Data는 TR(Repetition Time)과 TE(Echo Time)에 따라서 신호 대잡음비(SNR), 조직들간의 대조도(Contrast), Artifact 및 촬영시간이 결정된다. 이 연구에서는 TR/TE를 줄이는 기법을 이용한 Radial Imaging 영상기법을 제시하고자 한다. 대상 및 방법: 일반적인 Radial Imaging 기법에 HASTE 기법과 Non-uniform sampling 기법의 특징을 이용하여 구현하였으며, TR/TE를 줄일 수 있었으며 얻어진 K-space Data는 가변주파수 역 Fourier Transform을 이용하여 Projection Data를 재구성한 후 Back Projection 기법을 이용하여 최종 영상을 재구성한다.

  • PDF

Numerical Analysis of the Expansion of a Metalic Cylinder Under Electormagnetic Pulse (전자장 pulse 하의 금속 Cylinder의 팽창에 대한 연구)

  • Seo, Ju Ha
    • Journal of Industrial Technology
    • /
    • v.8
    • /
    • pp.71-80
    • /
    • 1988
  • 높은 전압으로 충전된 Capacitor를 순간적으로 원통형 coil에 방전하면 순간적으로 강한 전자장 impulse가 발생한다. 이때 coil를 둘러 싼 금속 tube는 radial 방향의 힘을 얻어 팽창한다. 본 논문은 이때 tube내의 전자장분포와 tube 벽의 움직임을 integral equation method를 사용하여 해석하였다.

  • PDF

Computerized pulse diagnosis system (컴퓨터 맥진시스템)

  • Lee, Ho-Jae;Huh, Woong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF