• Title/Summary/Keyword: Radial angle

Search Result 380, Processing Time 0.025 seconds

ON INTEGRAL MEANS OF DERIVATIVES OF UNIVALENT FUNCTIONS

  • Elhosh, M.M.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.24 no.1
    • /
    • pp.13-17
    • /
    • 1987
  • Let S denote the class of nivalent functions normalized so that f(0)=f'(0)-1=0 in vertical bar z vertical bar <1. Let $S_{\alpha}$$^{*}$, -.pi./2<.alpha.<.pi./2, denote the subclass of S that satisfies Re $e^{i{\alpha}}$zf'(z)/f(z).geq.0 in vertical bar z vertical bar <1; then f is called .alpha.-spiral-like and the case .alpha.=0 is the class of normalized starlike functions [6, pp.52]. Let T denote the class of functions f normalized as above and satisfying Im z[Im f(z)]..geq.0 in vertical bar z vertical bar <1; then f is called typically real and T contains those functions of S whose coefficients are real [6, pp.55]. Also, in view of [6, pp.231], let B(.lambda.) be the class of function normalized as above and map vertical bar z vertical bar <1 onto the complement of an arc with radial angle .lambda.(0<.lambda.<.pi./2). The radial angle is meant to be the angle between the tangent and radial vectors to the arc. This note includes a sharp version for Corollary 1 of [2] when f.mem. $S_{\alpha}$$^{*}$ as well as a logarithmic coefficient estimate.nt estimate.

  • PDF

SHAPING ABILITY OF NICKEL-TITANIUMROTARY FILES (다양한 엔진 구동형 파일의 근관 성형 능력 비교)

  • Park, Wan-Ky;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2004
  • This study compared the shaping ability of nickel-titanium rotary files with different rake angle and radial land. The nickel-titanium files used in this study were Profile(Dentsply, Maillefer, Ballaigues, Switzerland), Hero 642(Micromega, Besancon, France) and K3 (SybronEndo, Glendora, Ca, USA) file. Resin blocks substituted for root canals. 36 resin blocks were divided into 3 groups with 12 canals each The time for canal preparation was recorded. The images of pre- and postoperative resin canal were scanned and those were superimposed Amounts of canal deviation, total canal widths, inner canal widths, and outer canal widths were measured at apical 1, 2 ,3, 4, 5, 6, and 7mm levels. The amount of canal deviation was the smallest in Profile group , and the time far canal preparation was the shortest in Hero 642 group. K3 group resulted in competent characteristics in both measurements. Positive rake angle seemed to result in fast shaping of root canal and radial land guide the instrument in center of the canals and around curvatures. Radial land also tended to reduce the sense of screwing into the root canal. The proper selection of the nickel-titanium fie based on the knowledge about file design is needed for the safer, simpler and faster root canal therapy.

Immersion Ration Estimation Using Spindle Motor Current during Milling (밀링공정에서 주축모터전류를 이용한 절입비 추정)

  • Cho, K.-J.;Kwon, W.-T.;Cho, D.-W.;Chu, C.-N.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.222-229
    • /
    • 1999
  • In order to regulate cutting torque in milling, monitoring system should be set to a certain threshold. Radial immersion ratio is an important factor to determine the threshold and should be estimated in process for automatic regulation. In this paper, on-line estimation of the radial immersion ration using spindle motor current in face milling is presented. When a tooth finishes sweeping, a sudden drop of cutting torque occurs. This torque drop is equal to cutting torque acting on a single tooth at the swept angle of cut and can be acquired form cutting torque signals. Average cutting torque per revolution can also be calculate form cutting torque signals. The ratio of cutting torque acting on a single tooth at the swept angle of cut to the average cutting torque per revolution is a function of the swept angle of cut and the number of teeth. Using the magnitude of this ratio, the radial immersion ratio is estimated. Identical algorithm is adopted to estimate the immersion ratio based on the spindle motor current measurement. The experiments performed under different cutting conditions show that the radial immersion ratio can be estimated within 10% error range by the proposed method using spindle motor current.

  • PDF

In-process Immersion Ratio Estimation Using Spindle Motor Current during Face Milling (정면밀링공정중 추축모터전류를 이용한 절입비의 실시간 추정)

  • 조규진;오영탁;권원태;주종남
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2000
  • In order to regulate cutting torque in milling, monitoring system should be set to a certain threshold. Radial immersion ratio is an important factor to determine the threshold and should be estimated in process for automatic regulation. In this paper, on-line estimation of the radial immersion ratio using spindle motor current in face milling is presented. When a tooth finishes sweeping, a sudden drop of cutting torque occurs. This torque drop is equal to the cutting torque acting on a single tooth at the swept angle of cut and can be acquired from cutting torque signals. Average cutting torque per revolution can also be calculated from cutting torque signals. The ratio of cutting torque acting on a single tooth at the swept angle of cut to the average cutting torque per revolution is a function of the swept angle of cut and the number of teeth. Using the magnitude of this ratio, the radial immersion ratio is estimated. Identical algorithm is adopted to estimate the immersion ratio based on the spindle motor current measurement. The experiments performed under different cutting conditions show that the radial immersion ratio can be estimated within 10% error range by the proposed method using spindle motor current. Varying immersion ratio is also estimated well using the presented algorithm.

  • PDF

Dynamic Characteristics of HDD Slider by Perturbed Finite Element Method (교란 유한요소법을 이용한 하드 디스크 슬라이더의 동특성 해석)

  • Hwang Pyung;Khan Polina V.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.143-148
    • /
    • 2004
  • The numerical analysis of the hard disk drive slider is presented. The pressure distribution was calculated using the finite element method. The generalized Reynolds equation was applied in order to include the gas rarefaction effect. The balance of the air bearing force and preload force was considered. The characteristics of the small vibrations near the equilibrium were studied using the perturbation method. Triangular mesh with variable element size was employed to model the two-rail slider. The flying height, pitching angle, rolling angle, stiffness and damping of the two-rail slider were calculated for radial position changing from the inner radius to the outer radius and for a wide range of the slider crown values. It was found that the flying height, pitching angle and rolling angle were increased with radial position while the stiffness and damping coefficients were decreased. The higher values of crown resulted in increased flying height, pitching angle and damping and decreased stiffness.

  • PDF

Velocity Measurement Technique in a Narrow Passage by Hot-wire Anemometer (열선유속계를 이용한 좁은 유로 내 유속 측정법)

  • Kim, Won-Kap;Han, Seong-Ho;Choi, Young-Don
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.191-201
    • /
    • 2007
  • It was noted by the several researchers that the voltage outputs in response to a single yawed hot-wire sensor in a flow perpendicular to the axis deviate from the theoretical voltage output by King's law and Jorgensen's relation. This study noticed that the calibration coefficients of original Grande's method are not constant and fairly sensitive to the radial angle (${\alpha}_{R}$). For more accuracy, this study interpolated the parameters of the Grande relation as a function of radial angle and compared velocity components with ones by Jorgensen and original Grande relation in the calibration jet flow. Finally, as a test case, 3-dimensional turbulent flows of the inlet plane of 180 degree bend are measured and compared the velocity components by above three methods and showed the characteristics of the flows.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

Rotation Angle Estimation Method using Radial Projection Profile (방사 투영 프로파일을 이용한 회전각 추정 방법)

  • Choi, Minseok
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.10
    • /
    • pp.20-26
    • /
    • 2021
  • In this paper, we studied the rotation angle estimation methods required for image alignment in an image recognition environment. In particular, a rotation angle estimation method applicable to a low specification embedded-based environment was proposed and compared with the existing method using complex moment. The proposed method estimates the rotation angle through similarity mathcing of the 1D projection profile along the radial axis after converting an image into polar coordinates. In addition, it is also possible to select a method of using vector sum of the projection profile, which more simplifies the calculation. Through experiments conducted on binary pattern images and gray-scale images, it was shown that the estimation error of the proposed method is not significantly different from that of complex moment-based method and requires less computation and system resources. For future expansion, a study on how to match the rotation center in gray-scale images will be needed.

CONTACT PRESSURE DISTRIBUTION OF RADIAL TIRE IN MOTION WITH CAMBER ANGLE

  • Kim, Seok-Nam;Kondo, Kyohei;Akasaka, Takashi
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.387-394
    • /
    • 2000
  • Theoretical and experimental study is conducted on the contact pressure distribution of a radial tire in motion under various camber angles. Tire construction is modelled by a spring bedded elastic ring, consisted of sidewall springs and a composite belt ring. The contact area is assumed to be a trapezoidal shape varying with camber angles and weighted load. The basic equation in a quasi-static form is derived for the deformation of a running belt with a constant velocity by the aid of Lagrange-Euler transformation. Galerkin's method and stepwise calculation are applied for solving the basic equation and the mechanical boundary condition along both sides of the contact belt part subjected to shearing forces transmitted from the sidewall spring. Experimental results on the contact pressure, measured by pressure sensors embedded in the surface of the drum tester, correspond well with the calculated ones for the test tire under various camber angles, running velocities and weighted loads. These results indicate that a buckling phenomenon of the contact belt in the widthwise direction occurs due to the effect of camber angle.

  • PDF

The Effects of Sa-Am Acupuncture on the Radial Pulse in Healthy Human Subjects: A Comparative Study of Pericardium jung-gyuck and Triple Energizer jung-gyuck

  • Kim, Tae-Min;Kim, Jea-Hong;Lee, Hyun-Suk;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate the effects of Sa-am acupuncture with Pericardium jung-gyuck (SA-acu-PC) and Triple Energizer jung-gyuck (SA-acu-TE) on the radial pulse in healthy human subjects. Methods: Sixty healthy subjects participated in this study and divided into three groups randomly: Control group(C), Pericardium jung-gyuck group(PC), Triple Energizer jung-gyuck group(TE). Radial pulse was measured by 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results: 1. The changes observed in periodic parameters are considered as the common effects of both SA-acu-TE and SA-acu-PC. SA-acu-TE was more effective than SA-acu-PC in these effects. 2. The effects of SA-acu-PC appeared in the pulse amplitude, pulse area, and pulse power volume mainly at the left chon position, and 3. The effects of SA-acu-TE appeared in the radial augmentation index and main peak angle mainly at the right gwan position. Conclusions: The effects of SA-acu-PC and SA-acu-TE can be observed in the radial pulse. The increases in pulse amplitude, pulse area, and pulse power volume at the left chon may imply the effects of SA-acu-PC. And the decrease in the pulse power volume, the increases in radial augmentation index and main peak angle may imply the effects of SA-acu-TE.