• 제목/요약/키워드: Radial Distribution System

검색결과 238건 처리시간 0.025초

Mathematical description of drug distribution in the isolated organ

  • Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • 제3권1호
    • /
    • pp.13-16
    • /
    • 1980
  • The model of an isolated organ system has been constructed to simulated the behavior of drug in the circulatory system of an acting organ or site. The model is developed on the following assumptions : The drug in the microcirculatory system cannot permeate the capilary walls. The capilary bed is modeled as a simple ideal plug flow system with and without radial concentration gradient. The mathematical model is developed from basic considerations of drug distribution with hemodynamical and pharmacokinetical meanings. It is considered that a nonmetabolic drug substance is injected into the arterial inflow site of an isolated organ at a constant rate. The concentration of the drug in the outflow site is mathematically expressed as a function of time.

  • PDF

최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구 (A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region)

  • 김장권
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF

개선된 선로교환 기법을 이용한 방사상 전력계통의 최적 라우팅 알고리즘의 적용 (An Application of the Optimal Routing Algorithm for Radial Power System using Improved Branch Exchange Technique)

  • 김병섭;신중린;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.302-310
    • /
    • 2002
  • This paper presents an application of a improved branch exchange (IBE) algorithm with a tie branch power (TBP) flow equation to solve the Optimal Routing problem for operation of a radial Power system including power distribution system. The main objective of the Optimal Routing problem usually is to minimize the network real power loss and to improve the voltage profile in the network. The new BE algorithm adopts newly designed methods which are composed by decision method of maximum loss reduction and new index of loss exchange in loop network Thus, the proposed algorithm in this paper can search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been evaluated with the practical IEEE 32, 69 bus test systems and KEPCO 148 bus test system to show favorable performance gained.

DYNAMICAL EVOLUTION OF THE M87 GLOBULAR CLUSTER SYSTEM

  • Kim, Sung-Soo;Shin, Ji-Hye;Jin, Ho
    • 천문학회지
    • /
    • 제43권4호
    • /
    • pp.105-113
    • /
    • 2010
  • We study the dynamical evolution of the M87 globular cluster (GC) system using the most advanced and realistic Fokker-Planck (FP) model.By comparing our FP models with both mass function (MF) and radial distribution (RD) of the observed GC system, we find the best-fit initial (at M87's age of 2-3 Gyr) MF and RD for three GC groups: all GCs, blue GCs, and red GCs. We estimate the initial total mass in GCs to be $1.8^{+0.3}_{-0.2}{\times}10^{10}M_{\bigodot}$, which is about 100 times larger than that of the Milky Way GC system. We also find that the fraction of the total mass currently in GCs is 34\%. When blue and red GCs are fitted separately, blue GCs initially have a larger total mass and a shallower radial distribution than red GCs. If one assumes that most of the significant major merger events of M87 have ended by the age of 2-3 Gyr, our finding that blue (metal-poor) GCs initially had a shallower radial distribution supports the major merger scenario for the origin of metallicity bimodality.

네트워크 배전계통용 백업 보호협조에 관한 연구 (Research on Backup Protective Coordination for Distribution Network)

  • 김우현;채우규;황성욱;김주용
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.

The Globular Cluster System of the Virgo Giant Elliptical Galaxy NGC 4636

  • 박홍수
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.55.2-55.2
    • /
    • 2010
  • We present a photometric and spectroscopic study of the globular clusters (GCs) in the giant elliptical galaxy NGC 4636 in the Virgo cluster. The photometry of the GCs is based on HST/WFPC2 images for the inner region and deep, wide field Washington $CT_1$ CCD images for the outer region. We investigated the color distribution, the radial number density profile, the spatial distribution, and the mean color of the bright blue GCs about the GCs in NGC 4636. We obtained spectra of the GC candidates in NGC 4636 using the Multi-Object Spectroscopy (MOS) mode of Faint Object Camera and Spectrograph (FOCAS) on the SUBARU 8.2m Telescope. We measured the velocities for 105 GCs in NGC 4636. Using the 238 GCs obtained from combining our results with data in the literature, we investigated the kinematics of the GC system of NGC 4636: the rotation, the velocity dispersion, the radial variation, and the orbit. We also investigated the distribution and the radial variation of the metallicities, ages, and alpha-elements of the GCs in NGC 4636 derived using the absorption lines. We compared the GC kinematics of NGC 4636 with those of other six gEs, finding that the kinematic properties of the GCs are diverse among gEs. We found several correlations between the kinematics of the GCs and the global parameters of their host galaxies. Finally we discuss the implication of the results for the formation models of the GC system in gEs, and suggest a mixture scenario for the origin of the GCs in gEs.

  • PDF

Algorithm for Detecting, Indentifying, Locating and Experience to Develop the Automate Faults Location in Radial Distribution System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.36-44
    • /
    • 2010
  • This paper presents the design of an algorithm to detect, identify, and locate faults in radial distribution feeders of Provincial Electricity Authority (PEA). The algorithm consists of three major steps. First, the adaptive algorithm is applied to track/estimate the system electrical parameter, i.e. current phasor, voltage phasor, and impedance. Next process, the impedance rule base is used to detect and identify the type of fault. Finally, the current compensation technique and a geographic information system (GIS) are applied to evaluate a possible fault location. The paper also shows the results from field tests of the automate fault location and illustrates the effectiveness of the proposed fault location scheme.

밀도변화에 따른 CO기체 분자으I YHB 동경분포함수에 대한 연구 (A Density Dependent Study on YHB RDF of Gaseous CO Molecule)

  • 윤종호;김해원
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.456-460
    • /
    • 1999
  • Stockmayer 분자 모델을 도입하여 선형분자인 CO분자를 쌍극자 분자로 단순화하여 CO 기체의 YHB 동경분포함수 (radial distribution function)를 컴퓨터로 계산하였다. 얻어진 CO 분자의 YHB 동경분포함수의 신뢰도는 여러 온도에서의 밀도 변화에 따른 CO 기체의 압력을 계산하여 조사하였다. 계산된 압력들은 문헌에 알려진 CO기체의 압력과 잘 일치하였으며 계산에 사용된 온도는 273, 298, 373 K, 그리고 조사한 밀도의 범위는 최대 약 $0.013/{\AA}^3$ (최대 압력 = 1000 atm)까지이다. 계산된 압력들이 문헌에 나타난 실험치와 잘 일치하는 것으로 나타났으므로 구해진 YHB 동정분포함수는 CO 분자의 압력과 같은 밀도변화에 민감한 각종 물리 화학적 평형 양들을 신뢰성있게 계산 및 예측할 수 있을 것으로 기대된다. 또한 이 연구에서 CO 기체의 dipole-dipole 상호작용은 약 2.5 분자직경까지 효과적으로 작용하는 것으로 나타났다.

  • PDF

동경방향 스펙클 전단 간섭계를 이용한 대칭형 물체의 진동 모드 특성에 관한 연구 (A study on characteristics of mode shapes of symmetrical objects using radial Electronic Shearograhpy)

  • 최장섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.319-324
    • /
    • 1996
  • In this paper, radial sheared eletronic shearopgraphy was studied in order to measure vibration characteristics of circular or radial symmetric objects. We calculated amplitude of vibration by using eletro-optic holography theory, and utilized a porror prism for optical arrangement of sheared two images in this experiment. In this case, the data measured by shearing interferometer give us a distribution of the gradient of vibration amplitude. This developed system is applied to symmetical objects such as fans of airconditioner and circular plates to test vibration characteristics.

  • PDF

Artificial Intelligence Application using Nutcracker Optimization Algorithm to Enhance Efficiency & Reliability of Power Systems via Optimal Setting and Sizing of Renewable Energy Sources as Distributed Generations in Radial Distribution Systems

  • Nawaf A. AlZahrani;Mohammad Hamza Awedh;Ali M. Rushdi
    • International Journal of Computer Science & Network Security
    • /
    • 제24권1호
    • /
    • pp.31-44
    • /
    • 2024
  • People have been using more energy in the last years. Several research studies were conducted to develop sustainable energy sources that can produce clean energy to fulfill our energy requirements. Using renewable energy sources helps to decrease the harm to the environment caused by conventional power plants. Choosing the right location and capacity for DG-RESs can greatly impact the performance of Radial Distribution Systems. It is beneficial to have a good and stable electrical power supply with low energy waste and high effectiveness because it improves the performance and reliability of the system. This research investigates the ideal location and size for solar and wind power systems, which are popular methods for producing clean electricity. A new artificial intelligent algorithm called Nutcracker Optimization Algorithm (NOA) is used to find the best solution in two common electrical systems named IEEE 33 and 69 bus systems to examine the improvement in the efficiency & reliability of power system network by reducing power losses, making voltage deviation smaller, and improving voltage stability. Finally, the NOA method is compared with another method called PSO and developed Hybrid Algorithm (NOA+PSO) to validate the proposed algorithm effectiveness and enhancement of both efficiency and reliability aspects.