촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례 (An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi)

  • 이전;이유정;전영주;이혜정;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF

3채널 맥파 측정 시스템 개발 (Development of 3-channel Pulse Wave Measurement System)

  • 김은근;허현;남기창;강희정;허영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu;Chung, Wan-Young
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.239-244
    • /
    • 2017
  • Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

무맥증 수술치험 2례 (Pulseless Disease: Report of Two Cases)

  • 박응범
    • Journal of Chest Surgery
    • /
    • 제3권2호
    • /
    • pp.127-132
    • /
    • 1970
  • A patient was 29 year old house wife who was admitted to the Yonsei University Medical Center on 6 th of Nov., in 1970, with chief complaints of complete loss of bilateral visual acuity, generalized weakness, frequent palpitations, claudication of masseter muscles and intermittent fainting. These symptoms were developed 5 years prior to admission. Physical finding on admission revealed complete loss of bilateral visual acuity, absence of both radial and carotid pulse, but there was good femoral and popliteal pulse. She couldn't open her mouth as she desired and had weakness of mastication. Radiological findings of plane chest PA were not significant. Aortogram(Cineangiogram) showed non-visualization of both carotid and subclavian arteries. It showed only innominate and interal mammary artery preoperatively. The operative findings were as follows: There were complete obliterative changes in both common carotid and subclavian arteries, and periarteritis in the innominate artery. Tube Dacron Prosthesis Bypass with V-arm between innominate artery and both common carotid arteries was performed after thromboendarterectomy. Histopathological finding of the thromboend arterectomy specimen was compatible with pulseless disease, which showed marked fibrous thickening of intima and a diffuse inflammatory cell infiltration of the whole layers. Her postopererative course was uneventful. Follow up aortogram(Cineangiogram) was taken on 11th postoperative day, which revealed both common carotid arteries patent. Her preoperative Subjective symtoms disappeared remarkably, such as her visual acuity improved much, fainting and vertigo disappeared completely and she can go to bath room without difficulty and help. Another patient was 34 year old house wife who was admitted on August, 1964 with chief complaints of frequent fainting and progresive visual loss. She was operated only thromboendarterectomy of both common carotid arteries. Postoperative course was smooth and subjective symptoms were disappeared.

  • PDF

A Brachial Artery Pseudoaneurysm Treated with a Bifurcated Y-Shaped Artificial Vessel Graft

  • Joon seok Oh;Seokchan Eun
    • Archives of Plastic Surgery
    • /
    • 제49권6호
    • /
    • pp.755-759
    • /
    • 2022
  • Brachial artery aneurysms are rare diseases that may be caused by infection or trauma. We report a case of a 71-year-old man who presented with a mass in his right antecubital fossa that increased in size slowly over time. Three years ago, the patient underwent ascending and total-arch replacement with artificial vessel graft to treat aortic root and ascending aorta aneurysm. Preoperative physical examination of right upper extremity showed a nonpulsatile mass with normal pulse of axillary, brachial, and radial arteries. The mass was removed and brachial artery reconstruction was done initially using saphenous vein graft. Two months later, the patient revisited with recurrent pseudoaneurysm, involving the bifurcation point of brachial artery. Aneurysm was totally resected and the brachial artery was reconstructed by interposition graft using a bifurcated GORE-TEX artificial vessel graft. The patient healed without complication and no recurrence was observed. Artificial vessel graft is an available option for reconstruction, and revascularization of vessel defect after excision of brachial artery aneurysm may involve bifurcation point.

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과 (Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

맥파의 특징점 추출 방법에 따른 만성위염 판별 모형 (Classification Model of Chronic Gastritis According to The Feature Extraction Method of Radial Artery Pulse Signal)

  • 최상호;신기영;김재욱;진승오;이태범
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.185-194
    • /
    • 2014
  • 한국에서 만성위염은 10명당 한 명 꼴로 발생하는 질병이다. 만성위염을 진단하기 위해서 일반적으로 내시경 검사를 하지만 이는 환자에게 고통을 주고 비용이 비싸다는 단점을 가지고 있다. 한편 비침습적이고 저비용인 전통한방의학의 맥진에 따르면, 오른쪽 손목의 '관' 위치에서 비위의 기능적 이상을 진단할 수 있다. 본 연구에서는, 전통한방의학의 견해에 따라 오른쪽 손목 '관' 부위의 맥파를 분석하여 만성위염 판별모델을 개발하였다. 모델의 판별률을 비교하기 위해, 피크-밸리 검출법과 가우시안 모델을 적용한 상이한 방법의 특징점 추출방법에 대해 선형판별분석 기법과 로지스틱 회귀분석법을 적용해 보았다. 그 결과, 판별모델과 특징점 추출 방법에 따라 77%~89%의 민감도와 72%~83%의 특이도를 보였고 각 모델의 평균 판별률은 약 80% 내외로 얻어졌다. 구체적으로, 가우시안 모델이 상대적으로 우수한 민감도(89.1%와 87.5%)를 보인 반면, 피크-밸리 검출법은 우수한 특이도(82.8%와 81.3%)를 보였고, 평균적인 판별률에 있어서는 가우시안 모델이 1.2% 정로 앞섰다(80.9% vs 79.7%). 결론적으로, 전통의학적 맥진원리에 기반한 요골동맥 맥파의 특성을 이용하여 유의미한 만성위염 판별모델을 얻을 수 있었고, 민감도에 있어서 가우시안 모델이 더 우수하였고, 특이도에 있어서 피크-밸리 검출법이 더 우수하였다.

비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구 (Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement)

  • 김은근;남기창;허현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF

다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구 (Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices)

  • 최상대;김미선;안명천;최영근;김기왕;박달호;황도근;이상석
    • 한국자기학회지
    • /
    • 제16권4호
    • /
    • pp.216-220
    • /
    • 2006
  • 10개의 다중 홀(Hall)소자를 이용하여 요골동맥에 놓여진 영구자석의 위치 변화에 따른 전압의 변화를 전기적 신호로 얻었다.전기적 신호는 맥의 파형 신호를 의미하며 이들을 다시 회로의 하드웨어를 통해 신호들을 미분하여 자장의 변화 신호만 얻었다.소프트웨어를 통해 위치 변화에 따른 자장 변화의 크기에 따라 그 형태를 3차원 영상을 얻어 착용형 맥진기로서의 개발 가능성을 보여주었다.