• Title/Summary/Keyword: Rad4

Search Result 309, Processing Time 0.025 seconds

Dynamic analysis of wind turbine wake (풍력 발전 터빈 후류의 동적 분석)

  • Um, Young Han;Kim, Yun Gu;Park, Sung Goon
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.59-65
    • /
    • 2020
  • Vertical axis wind energy systems including 3 and 4 blades are numerically investigated in a two-dimensional (2D) computational domain. The power coefficient (Cp) is adopted to measure the efficiency of the system and the effect of the rotating velocity on the power coefficient is analyzed for the two different systems. The rotating velocity varies from 30 rad/s to 90 rad/s, which corresponds to the tip speed ratio (T.S.R) of 0.5 to 1.5. The torque exerted on the blades is mainly determined by the aerodynamic force in the x-direction and maximized when the blade is positioned at around θ = 186°. The efficiency of the 4-blade system is higher than that of the 3-blade system within the tip speed ratio range between 0.5 and 0.67, besides where the 3-blade system shows a better performance. For the 3-blade system, the maximum efficiency is reached to 0.082 at the tip speed ratio of 1.083. The maximum efficiency of the 4-blade system is 0.071 at T.S.R. = 0.92. The velocity fields in the x-direction, pressure fields, and the vorticity magnitude are analyzed in detail for the optimal cases of the 3- and 4-blades systems, respectively.

Interstitial Radium Implantation and Cobalt-60 Irradiation of the Tongue Cancer (IbidI) (설암의 조직간내 라디움치료에 관하여)

  • 안경성;박주방;윤용규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.16.1-16
    • /
    • 1972
  • In 1971 there were 5 cases of the tongue cancer in stage I & II treated concomitantly with interstitial radium implantation and Cobalt-60 irradiation at the Yonsei University Hospital Cancer Center. This is the interim report of the course of the primary site of those treated cases.

  • PDF

Effect of ionizing radiation on cultured submandibular gland (SG) cells of mouse (전리 방사선 조사에 의한 마우스 배양 악하선 세포의 변화)

  • Lee, Song-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.4 no.1
    • /
    • pp.71-77
    • /
    • 1990
  • The present study was undertaken to investigate effects of ionizing radiation on DNA synthesis and chromosomal abnormality in cultured submandibular gland(SG) cells. SG cells from C57BL/6N Crj mice were cultured in Dulbecco's modified Eagle's medium (DME) supplemented with $10\%$ fetal bovine serum, antibiotics and fungizone. The cultured SG cells were irradiated with graded doses of gamma ray ($^{60}Co$) at a dose rate of 58.4rad/min. The effect of irradiation of $^{60}Co$ on DNA synthesis in cultured cells was evaluated by measuring the incorporation of 3H-TdR. Using conventional chromosome techniques and Giemsa staining methods, chromosomal abnormalities in cultured SG cells, induced by irradiation of $^{60}Co$ werw examined. Cytological observations were carried out by a light microscope with high resolving power. The results obtained were as follows : 1. DNA synthesis of SG cells was quantitatively dependent on a radiation dose compare to control. 2. A polyploids and few chromosome-type break, such as single and double breaks, deltions and triradial figures were more predominantly in irradiated SG cells than in control. This increase of chromosomal abnormality was in the proposition to the irradiation doses.

  • PDF

An Experimental Research on Uniform Corrosion of Inconel 600 and 690 Tubing Material (Inconel 600 및 690 튜브 재질의 일반 부식에 관한 실험적 연구)

  • Yeom Yu-Sun;Hwang Jung-Lae;Jun In-Sub;Kim Soong-Pyung;Yoon Jang-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.103-116
    • /
    • 2006
  • By executing corrosion experiment on Inconel 600, 690 used to material of S/G tube in domestic NPP, this paper show estimation of amount of product such as Co-58, Co-60, Cr-51, Mn-54, Fe-59 which are main exposure cause to the workers in NPP. Therefore, Making the 12 samples consisted of Inconel 600, 690, whole corrosion experiment was carried out for 60 days(each pH by 20 days). The conditions of those tests were similar or more harsh than actual conditions of domestic NPP. The Glow Discharge Spectrometer(GDS) was used for quantitative analysis of results. The results of using GDS, the Inconel 600 corrodes more than Inconel 690 at pH 7 and pH 9. However, it is observed that Inconel 690 corrodes more than Inconel 600 at pH 4. Those results is estimated that test sections had the effect of transient. The long terms of experiment is required to minimize and solve the problem.

  • PDF

Ultrastructural Study on the Ependymal Cells of the Read-Irradiated Rats (방사선이 뇌실막세포의 미세구조에 미치는 영향)

  • Ahn, E-Tay;Cho, Hwee-Dong;Kim, Jin-Gook;Park, Kyung-Ho;Ko, Jeong-Sik
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.11-23
    • /
    • 1999
  • Ultrastructure of the ependymal cells of X-irradiated rats on their head were studied. Rats weighing $200\sim250gm$ were X-irradiated on their head and neck areas. Total exposures were 3,000 rads or 6,000 rads depending on experimental groups. And irradiated rats were sacrificed on 6 hours, 2 days and 6 days following the radiation exposures. Animals were perfused through the heart with 1% glutaraldehyde-1% paraformaldehyde solution, under ether-anesthesia. The tissues from the wall of lateral ventricles were fixed in the 2% osmium tetroxide solution. The results observed with electron microscope were as follow: 1. In 6 hours group, many ependymal cells were swelled, luminal portions of cytoplasms of some cells protruded into the ventricular lumen, and many cilia were lost or irregularly altered. 2. In 2 days group, ependymal cells were swelled more severely and subependymal edema were pronounced. 3. Protruded cytoplasm contained usually basal bodies of cilia, groups of mitochondria, endoplasmic reticula , etc. 4. Following X-irradiations, some protruded masses contained neural elements including the axon terminals with dense core vesicles. Axons and axon terminals were also found in the enlarged intercellular spaces among ependymal cells. From the above results, the heavy irradiation on the head area of the rat induced alteration of the ependymal cells lining the lateral ventricle. Hence the ependymal functions of selective barrier, protective barrier, and metabolic barrier could be altered following X-irradiation on the head.

  • PDF

Studies on Utilization of Bark by Carbonization (수피의 탄화이용에 관한 연구)

  • Kim, Byung-Ro;Lee, Jae-yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.40-51
    • /
    • 2006
  • The objective of this research is to analyze a possibility for the utilization of carbonized bark and develop the technique for carbonization of bark for using as the adsorbent, the soil improvement agent, the carrier for microbial activity, health products, and so on. The properties of bark charcoals such as methylenehlue adsorption (MBA), equilibrium moisture content (EMC), far infra rad emissivity, pH, water retention and caloric value were analyzed. The MBA values of bark charcoals carbonized for 8 hr of carbonization time at $800^{\circ}C$ of carbonization temperature for Larix leptolepis, Pinus koraiensis, Pinus rigida were greater than 110 mg/g. The bark charcoals pH values of all three species that were carbonized for 4 hr of carbonization time at $400^{\circ}C$ of carbonization temperature was 6.6 and carbonized for 4 hr at 600 and $800^{\circ}C$ was about 9. Therefore the bark charcoals of those species could be used as charcoals if the carbonization temperature and time were controlled.

Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength (패널존의 강도비에 따른 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Young;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.1 s.24
    • /
    • pp.11-20
    • /
    • 2007
  • The study proposes the method to cancel the scallop to avoid fracture of the circumstance of the scallop at H shape column-to-beam connection and reinforce at beam flange two faces with the cover plates and rib. A total of four specimens were tested to enhance seismic performance of building structure by reducing the frequency of stress concentration and preventing the brittle fracture of scallop. For this purpose, four full-scale test specimens were made and loaded with quasi-static reversed cyclic loading. The main analytical parameters are panel-zone-strength ratio, yield strengths, initial stiffness, total plastic rotation, contribution of each element to total plastic rotation and energy dissipation capability. For the specimens tested under repeated loading, the experimental result was satisfied with seismic performance requirement as the Special Moment Frames (SMF). The analysis results show that all of the test specimens were found to have good performance to 4% story drift and satisfied the criteria for the plastic roation capacity of SMFs that is 0.03 rad. according to the 1997 AISC seismic provision.

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

A Study on the Double Sinusoidal Modulated PWM Inverter (2중 정현파 PWM 인버어터에 관한 연구)

  • 윤병도;이양우;차득근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.3
    • /
    • pp.68-76
    • /
    • 1989
  • 본 논문은 2중 정현파 변조 PWM 인버어터의 출력전압 파형을 해석하고 6502 마이크로 컴퓨터에 의한 3상 유도전동기의 인버어터 구동특성을 고찰하였다. 2중 정현파 변조신호는 1주기에 $4\pi$/3[rad] 기간동안 변조신호가 발생되게 하였으므로 인버어터의 스위칭 손실은 정현파 PWM 인버어터보다 감소시킬 수 있다. 인버어터 출력 선간전압의 기본파 진폭치는 2중 정현파 PWM 인버어터가 종래의 정현파 PWM 인버어터 보다 이론치는 1.15배 되지만 FFT 분석기에 의한 실제 측정값은 1.13배로 나타났다.

  • PDF

Experimental Study on Signal Sensing of a High Sensitive Fiber Optic Hydrophone (실험을 통한 소형 고감도 광섬유 하이드로폰의 감지성능 연구)

  • 김정석;윤형규;설재수
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1152-1156
    • /
    • 1999
  • In this study, a fiber optic air-backed mandrel hydrophone has been constructed and performance of acoustic signal detection has been measured. The hydrophone is based on a Mach-Zehnder interferometer with 35 m of sensing fiber. The sensitivity is measured up to -128 dB re rad/$\mu$ Pa in range from 1.4 kHz to5 kHz. A system with this design of hydrophone may be applied to detect low frequency underwater acoustic signals.

  • PDF